Emerson CF230BS00, CF230ORB00, CF230WW00 Trouble Shooting, Trouble Probable Cause Suggested Remedy

Models: CF230BS00 CF230ORB00 CF230WW00

1 20
Download 20 pages 40.73 Kb
Page 17
Image 17

Trouble Shooting

! WARNING: For your own safety, turn off power at fuse box or circuit breaker before trouble shooting your fan.

TROUBLE

PROBABLE CAUSE

SUGGESTED REMEDY

 

 

 

1. Fan will not start.

1. Fuse or circuit breaker blown.

1.Check main and branch circuit fuses or circuit

 

 

breakers.

 

2. Loose electrical connections to the fan.

2.Check line wire connections to fan .

 

 

! WARNING: Make sure main power is

 

 

turned OFF.

 

3. Reversing switch in neutral position.

3.Make sure reversing switch position is all the

 

 

way to one side.

 

4. Fan wall switch is OFF.

4.Turn the switch ON.

 

5. Fan/Light remote control is OFF.

5.Turn ON fan/light remote control.

 

6. Remote control battery is weak.

6.Replace the remote control batteries.

 

 

 

2. Fan sounds noisy.

1. Blades not attached to fan.

1.Attach blades to fan before operating.

 

2. Loose screws in motor housing.

2.Check to make sure all screws in motor

 

 

housing are snug (not over-tight).

 

3. Screws securing fan blade flanges to

3.Check to make sure the screws which attach

 

motor hub are loose.

the fan flanges to the motor hub are tight.

 

 

! WARNING: Make sure main power is

 

 

turned OFF.

 

4. Screws holding blades to flanges

4.Tighten screws securely.

 

are loose.

 

 

 

 

3. Fan wobbles

1. Setcrews in motor coupling are not

1.Raise coupling cover and tighten setscrews

excessively.

tightened securely.

securely.

 

2. Setscrew in hanger ball/downrod

2.Tighten the setscrew in the hanger ball/

 

assembly is loose.

downrod assembly.

 

3. Screws securing fan blades to motor are

3.Check to be sure screws which attach the fan

 

loose.

blade to the motor are tight.

 

4. Fan blades are not seated properly.

4.Check to be sure that the screws securing the

 

 

fan blades seat firmly.

 

5. Hanger bracket and/or ceiling outlet box

5.Tighten the hanger bracket screws to the

 

is not securely fastened.

outlet box, and /or secure outlet box.

 

6. Fan blades out of balance.

6.Interchanging an adjacent (side-by-side)

 

 

blade pair can redistribute the weight and

 

 

result in smoother operation.

 

 

Or use supplied balancing kit to balance

 

 

blades.

 

 

 

17

U.L. Model No.: CF230

Page 17
Image 17
Emerson CF230BS00, CF230ORB00, CF230WW00 owner manual Trouble Shooting, Trouble Probable Cause Suggested Remedy