Emerson CF654ORB00, CF654OB00, CF654WW00, CF654WB00 Maintenance, Accessories, Trouble Shooting

Models: CF654ORB00 CF654AW00 CF654WB00 CF654WW00 CF654OB00

1 12
Download 12 pages 45.75 Kb
Page 9
Image 9
Maintenance

Maintenance

IMPORTANT CARE INSTRUCTIONS

for your Ceiling Fan

Periodic cleaning of your new ceiling fan is the only maintenance that is needed.

When cleaning, use only a soft brush or lint free cloth to avoid scratching the finish.

Abrasive cleaning agents are not required and should be avoided to prevent damage to finish.

!WARNING

Do not use water when cleaning your ceiling fan. It could damage the motor or the blades and create the possibility of an electrical shock.

Accessories

1.Ceiling Fan Light Kits (see store or catalog).

2.Ceiling Fan/Light Controls (see store or catalog).

3.Downrod Extension Kits (see store or catalog).

!WARNING

To reduce the risk of fire or electrical shock, do not use this fan with any solid-state speed control device.

!WARNING

The use of any other control not specifically approved for this fan could result in fire, shock and personal injury.

!WARNING

This product is designed to use only those parts supplied with this product and/or any accessories designated specifically for use with this product by Emerson Electric Co. Substitution of parts or acces- sories not designated for use with this product by Emerson Electric Co. could result in personal injury or property damage.

!WARNING: FOR YOUR OWN SAFETY TURN OFF POWER AT FUSE BOX OR CIRCUIT BREAKER BEFORE TROUBLE SHOOTING YOUR FAN.

Trouble Shooting

TROUBLE

PROBABLE CAUSE

 

SUGGESTED REMEDY

 

 

 

 

1. Fan will not start.

1. Reversing switch in neutral position.

1.

Make sure reversing switch position is all the way to one

 

 

 

side.

 

2. Fuse or circuit breaker blown.

2.

Check main and branch circuit fuses or circuit breakers.

 

3. Loose power line connections to the fan, or loose

3.

Check line wire connections to fan and switch wire

 

switch wire connections in the switch housing.

 

connections in switch housing.

 

 

 

 

2. Fan sounds

1. Blades not attached to fan.

1.

Attach blades to fan before operating.

noisy.

2. Screws securing fan blade flanges to motor

2.

Check to make sure the screws which attach the fan blade

 

are loose.

 

flanges to the motor are tight.

 

3. Wire connectors inside switch housing rattling.

3.

Check to make sure wire connectors in switch housing

 

 

 

are not rattling against each other or against the interior

 

 

 

wall of the switch housing.

 

4. Screws holding flanges to blades are loose.

4.

Tighten screws securely.

 

 

 

 

3. Fan wobbles

1. Setscrew in motor coupling is loose.

1.

Tighten the setscrew securely in the motor coupling.

or shakes

2. Setscrew in hanger ball/downrod assembly is

2.

Tighten the setscrew in the hanger ball/downrod

excessively.

loose.

 

assembly.

 

3. Screws securing fan blade flanges to motor

3.

Check to be sure screws which attach the fan blade

 

are loose.

 

flanges to the motor are tight.

 

4. Fan blade flanges not seated properly.

4.

Check to be sure the fan blade flanges seat firmly and

 

 

 

uniformly to the surface of the motor. If flanges are

 

 

 

seated incorrectly, loosen the flange screws and retighten

 

 

 

according to the procedure in the section on "How to Put

 

 

 

Your Ceiling Fan Together".

 

5. Hanger bracket and/or ceiling outlet box is not

5.

Tighten the hanger bracket screws to the outlet box,

 

securely fastened.

 

and/or secure outlet box.

 

6. Fan blades out of balance.

6.

Interchanging an adjacent (side-by-side) blade pair can

 

 

 

redistribute the weight and result in smoother operation.

 

 

 

 

9

Page 9
Image 9
Emerson CF654ORB00, CF654OB00 Maintenance, Accessories, Trouble Shooting, IMPORTANT CARE INSTRUCTIONS for your Ceiling Fan