Emerson CF700BS07, CF700WW07, CF700WPB07, CF700AW07, CF700AB07, CF700WB07, CF700CK07 Trouble Shooting

Models: CF700PBW07 CF700PB07 CF700OB07 CF700CK07 CF700BS07 CF700WB07 CF700AB07 CF700AW07 CF700WPB07 CF700WW07

1 8
Download 8 pages 10.16 Kb
Page 5
Image 5
Trouble Shooting

!WARNING: FOR YOUR OWN SAFETY TURN OFF POWER AT FUSE BOX OR CIRCUIT BREAKER BEFORE TROUBLE SHOOTING YOUR FAN.

Trouble Shooting

TROUBLE

 

PROBABLE CAUSE

 

SUGGESTED REMEDY

 

 

 

 

1. Fan will not start.

1. Fuse or circuit breaker blown.

1.

Check main and branch circuit fuses or circuit

 

 

 

 

breakers.

 

2.

Loose power line connections to the fan, or loose

2.

Check line wire connections to fan and switch

 

 

switch wire connections in the switch housing.

 

wire connections in switch housing.

 

 

 

! WARNING: Make sure main power is

turned

 

 

 

off.

 

3.

Reversing switch in neutral position.

3.

Make sure reversing switch position is all the

 

 

 

 

way to one side.

 

 

 

 

2. Fan sounds

1. Blades not attached to fan.

1.

Attach blades to fan before operating.

noisy.

2. Loose screws in motor housing.

2.

Check to make sure all screws in motor

 

 

 

 

housing are snug (not over-tight).

 

3.

Screws securing fan blade holders to motor

3.

Check to make sure the screws which attach

 

 

are loose.

 

the fan blade holders to the motor are tight.

 

4.

Wire connectors inside switch housing rattling.

4.

Check to make sure wire connectors in

 

 

 

 

switch housing are not rattling against each

 

 

 

 

other or against the interior wall of the switch

 

 

 

 

housing.

 

 

 

! WARNING: Make sure main power is

turned

 

 

 

off.

 

 

 

 

3. Fan wobbles

1. Setscrew in motor mount adapter is loose.

1.

Tighten setscrew in motor mount adapter.

or shakes

2.

Setscrew in hanger ball/downrod assembly is

2.

Tighten the setscrew in the hanger ball/

excessively.

 

loose.

 

downrod assembly.

 

 

 

 

3.

Screws securing fan blade flanges to motor

3.

Check to be sure screws which attach the fan

 

 

are loose.

 

blade flanges to the motor are tight.

 

4.

Fan blade flanges are not seated properly.

4.

Check to be sure the fan blade flanges seat

 

 

 

 

firmly and uniformly to the surface of the

 

 

 

 

motor. If flanges are seated incorrectly, loosen

 

 

 

 

the holder screws and retighten.

 

5.

Hanger bracket and/or ceiling outlet box is not

5.

Tighten the hanger bracket screws to the outlet

 

 

securely fastened.

 

box, and/or secure outlet box.

 

6.

Fan blades are out of balance.

6.

Interchanging an adjacent (side-by-side) blade

 

 

 

 

pair can redistribute the weight and result in

 

 

 

 

smoother operation.

 

 

 

 

 

5

Page 5
Image 5
Emerson CF700BS07, CF700WW07, CF700WPB07, CF700AW07, CF700AB07, CF700WB07, CF700CK07, CF700OB07, CF700PB07 Trouble Shooting