2.Mount one blade assembly to the motor hub by mating the alignment post (Figure 11) of the flange with one of the alignment slots in the motor hub (Figure 12). Then tighten the two captive screws in the flange to secure the flange to the motor hub. Repeat this procedure for the other four blade assemblies. Make sure all screws are tightened.

MOTOR HUB

CAPTIVE

BLADE FLANGE

ALIGNMENT

SCREW (2)

 

SLOT

 

 

Figure 12

Installing The Glass Shades

1.To install the glass shade, squeeze the retaining clips towards the bulb socket and slide on the glass shade (Figure 13). The spring clips will seat the shade and secure it in place.

2.To remove the shade, simply pull it off with a twisting motion.

Removal Of The

Light Fixture

NOTE: In some instances it may be desirable to install the ceiling fan without the light fixture. If this is the case, proceed as follows. (You may want to keep the light fixture for possible future use.)

1.Remove and retain the three screws securing the light fixture to the switch housing (Fixture 14). Remove and retain two wire connectors and disconnect the light fixture from the switch housing.

SWITCH

SCREW (3)

HOUSING

 

 

LIGHT

 

FIXTURE

Figure 14

2.Use the wire connectors to securely cap the each of the two wires in the switch housing (Figure 15).

3.Position the switch housing cover (supplied) on the switch housing so that the notch in the cover clears the reversing switch. Install the three screws to secure the cover.

SQUEEZE

 

RETAINING

RETAINING

CLIPS

CLIP

TOGETHER

 

AND SLIDE

 

ON GLASS

 

SHADE

 

SWITCH

HOUSING

DISCONNECT TWO WIRES FROM LIGHT FIXTURE AND SECURELY CAP WITH WIRE CONNECTORS

SCREW (3)

SWITCH HOUSING COVER

GLASS

SHADE

Figure 13

Figure 15