How to Hang Your

Ceiling Fan

!WARNING

The fan must be hung with at least 7' of clearance from floor to blades (Figure 9).

CEILING

AT LEAST

7'

Figure 9

FLOOR

!WARNING

The outlet box must be securely anchored and capable of withstanding a load of at least 50 lbs.

!WARNING

To reduce the risk of fire, electric shock, or personal injury, mount fan to outlet box marked acceptable for fan support, and use screws supplied with outlet box. Most outlet boxes commonly used for support of light fixtures are not acceptable for fan support and may need to be replaced. Consult a qualified electrician in in doubt.

1.Securely attach the hanger bracket to the outlet box using the two screws supplied with the outlet box. (Figure 10.)

OUTLET

BOX

NOTE: CEILING COVER,

 

SUPPLY WIRES AND

OUTLET

FAN WIRES OMITTED

BOX

FOR CLARITY.

 

 

HANGER

 

BRACKET

Figure 11

HANGER BALL/

 

DOWNROD ASSEMBLY

How to Wire Your Ceiling Fan

If you feel that you do not have enough electrical wiring knowledge or experience, have your fan installed by a licensed electrician.

! WARNING

To avoid possible electrical shock, be sure electricity is turned off at the main fuse box before wiring. NOTE: If you are not sure if the outlet box is ground- ed, contact a licensed electrician for advice, as it must be grounded for safe operation.

1.Connect the green grounding lead from the hanger ball and the green grounding lead from the hanger bracket to the grounding conductor of supply (this may be a bare wire or wire with green colored insulation). Securely connect wires with wire

connectors supplied.

 

BLACK AND BLUE

NOTE: CEILING COVER

 

OMITTED FOR CLARITY.

GROUND

FAN WIRES

 

 

WIRE

 

 

LISTED

 

WHITE SUPPLY

WIRE

 

CONNECTOR (3)

 

(NEUTRAL)

TWO SCREWS

 

SUPPLIED WITH

HANGER

OUTLET BOX

 

BRACKET

Figure 10

TAB

 

2.Carefully lift the fan and seat the hanger ball/down- rod assembly on the hanger bracket that was just attached to the outlet box (Figure 11). Be sure the groove in the ball is lined up with tab on the hanger bracket (Figure 10).

!WARNING

Hanger bracket must seat firmly against outlet box. If the outlet box is recessed, remove wall board until bracket contacts box. If bracket and/or outlet box are not securely attached, the fan could wobble or fall.

!WARNING

Failure to seat tab in groove could cause damage to electrical wires and possible shock or fire hazard.

GREEN WIRE

 

(GROUND) FROM

WHITE FAN

HANGER BRACKET

WIRE

 

GREEN WIRE

BLACK SUPPLY

Figure 12

(GROUND) FROM

(HOT)

HANGER BALL

 

 

 

NOTE: If you are using an Emerson Light Fixture with your fan, see Light Fixture Owner’s Manual for wiring.

2.Securely connect the fan motor white wire to the supply white (neutral) wire using wire connector supplied (Figure 12). Securely connect the fan motor black wire and blue wire to the supply black (hot) wire using wire connector supplied (Figure 12). After connections have been made, turn leads upward and carefully push leads into the outlet box, with the white and green leads on one side of the outlet box and the black and blue leads on the other side of the outlet box.

!WARNING

To avoid possible fire or shock, do not pinch wires between the hanger ball/downrod assembly and hanger bracket.

6

!WARNING

Check to see that all connections are tight, including ground, and that no bare wire is visible at the wire connectors, except for the ground wire. Do not operate fan until blades are in place. Noise and fan damage could result.

Page 6
Image 6
Emerson CF755W04, CF755PW04, CF755WW04, CF755NW04, CF755S04 warranty How to Hang Your Ceiling Fan, How to Wire Your Ceiling Fan