housing assembly with the holes in the plate. Secure the switch housing assembly by installing the three screws (Figure 6).

!WARNING

To avoid possible fire or shock, do not pinch wires between the switch cup assembly and the switch cup plate.

!WARNING

To reduce the risk of personal injury, do not bend the blade flange when installing the blade flanges, balancing the blades or cleaning the fan. Do not insert foreign objects in between rotating fan blades.

11.The blade flanges have an interlocking feature that must be fully engaged before tightening the screw. Make sure all the flanges are properly engaged and then tighten the flange screws. If one of the flanges does not seat properly on the motor hub, loosen the adjacent flange screws, re-engage and reseat the flanges, then tighten the screws again.

SWITCH HOUSING

CONNECTOR

MOTOR CONNECTOR

SWITCH HOUSING

MOUNTING SCREW (3)

Figure 5

SWITCH

HOUSING

ASSEMBLY

MOUNTING

SCREWS (3)

Figure 6

8.Turn fan assembly upside down in preparation for mounting fan blade assemblies.

9.Mount blade flanges to fan blades using three 3/16- 24 x 5/16” slotted Phillips blade screws and three blade washers (Figure 7).

3/16-24 x 5/16" SLOTTED PHILLIPS BLADE SCREW (3)

BLADE WASHER (3)

BLADE

ASSEMBLY

BLADE FLANGE SCREWS

Figure 8

12.You have now completed the assembly of your new ceiling fan. You can now proceed with hanging and wiring your fan.

Electrical Requirements

Your new ceiling fan will require a grounded electrical supply line of 120 volts AC, 60 Hz, 15 amp circuit.

The outlet box must be securely anchored and capa- ble of withstanding a load of at least 50 pounds.

!WARNING

To reduce the risk of fire, electric shock, or personal injury, mount fan to outlet box marked acceptable for fan support, and use screws supplied with outlet box. Most outlet boxes commonly used for support of light fixtures are not acceptable for fan support and may need to be replaced. Consult a qualified electrician if in doubt.

FAN BLADE

BLADE FLANGE

Figure 7

NOTE: Take care not to scratch fan housing when installing blades.

NOTE: Remove and discard the four shipping spacers and screws from the motor hub.

10. Loosely attach one blade assembly to the motor hub using two 1/4-20 x 1/2” Phillips oval head flange screws. Make sure the screws are NOT tightened. (Figure 8.) Repeat this procedure for

other four blade assemblies.

5

If your fan is to replace an existing ceiling light fixture, turn electricity off at the main fuse box at this time and remove the existing light fixture.

!WARNING

Turning off wall switch is not sufficient. To avoid possible electrical shock, be sure electricity is turned off at the main fuse box before wiring. All wiring must be in accordance with National and Local codes and the ceiling fan must be properly grounded as a precaution against possible electrical shock.

!WARNING

To avoid fire or shock, follow all wiring instructions carefully. Any electrical work not described in these instructions should be done or approved by a licensed electrician.

Page 5
Image 5
Emerson CF755WB04, CF755PW04, CF755WW04, CF755NW04, CF755S04, CF755OB04, CF755W04, CF755V04, CF755WPB04 Electrical Requirements