Emerson CF796CW0, CF796HGMO0 How to Wire Your Ceiling Fan, Using Your Ceiling Fan, Three-Speed

Models: CF796MP0 CF796HGMO0 CF796CW0

1 8
Download 8 pages 17.61 Kb
Page 6
Image 6
How to Wire

NOTE: CEILING COVER,

OUTLET

SUPPLY WIRES AND FAN

BOX

WIRES OMITTED FOR

 

CLARITY.

 

 

HANGER

 

BRACKET

Figure 8

HANGER BALL/

 

DOWNROD ASSEMBLY

!WARNING

To avoid possible fire or shock, do not pinch wires between the hanger ball/downrod assembly and hanger bracket.

How to Wire

Your Ceiling Fan

If you feel that you do not have enough electrical wiring knowledge or experience, have your fan installed by a licensed electrician.

!WARNING

To avoid possible electrical shock, be sure electricity is turned off at the main fuse box before wiring. NOTE: If you are not sure if the outlet box is ground- ed, contact a licensed electrician for advice, as it must be grounded for safe operation.

1.Connect the green grounding lead from the hanger ball and the green grounding lead from the hanger bracket to the grounding conductor of supply (this may be a bare wire or wire with green colored insu- lation). Securely connect wires with wire connec- tors supplied.

!WARNING

Check to see that all connections are tight, including ground, and that no bare wire is visible at the wire connectors, except for the ground wire. Do not operate fan until blades are in place. Noise and fan damage could result.

3.Screw the two threaded studs (supplied) into the tapped holes in the hanger bracket.

4.Lift the ceiling cover up to the threaded studs and turn until studs protrude through the holes in the ceiling cover (Figure 10).

5.Secure the ceiling cover in place by sliding lock- washers over the threaded studs and installing the two knurled knobs (supplied). (Figure 10). Tighten the knurled knobs securely until the ceiling cover fits snugly against the ceiling and the hole in the ceiling cover is clear of the downrod. Your fan is now wired to be turned on and off from the fan switch.

 

 

CEILING COVER

 

THREADED

LOCKWASHERS (2)

Figure 10

STUD

 

KNURLED KNOB

 

 

 

!WARNING

To avoid possible fire or shock, make sure that the electrical wires are completely inside the outlet box and not pinched between the ceiling cover and the ceiling.

6. Cut the 3-speed switch pull chain to a desired

length (optional). Connect the wood pendant (sup-

plied) to the 3-speed switch pull chain by sliding the

wooden pendant (small hole first) onto the pull

chain. Attach the chain coupler to the end of the

GROUND

WIRE

LISTED

BLACK AND BLUE FAN WIRES

chain and allow the wooden pendant to fall down

over the coupling.

WIRE

CONNECTOR (3)

GREEN WIRE (GROUND) FROM HANGER BRACKET

GREEN WIRE (GROUND) FROM HANGER BALL

WHITE SUPPLY (NEUTRAL)

WHITE FAN

WIRE

BLACK SUPPLY (HOT)

Using Your Ceiling Fan

1.

Restore electrical power to the outlet box by turning

 

the electricity on at the main fuse box.

2.

Check the operation of the fan by gently pulling on

 

the pull chain switch.

3.

All fans are shipped from the factory with the

 

reversing switch positioned to circulate air down-

 

ward. If airflow is desired in opposite direction, turn

 

your fan off and wait for the blades to stop turning,

Figure 9

NOTE: CEILING COVER

OMITTED FOR CLARITY.

NOTE: If you are using an Emerson Light Fixture with your fan, see Light Fixture Owner’s Manual for wiring.

2.Securely connect the fan motor white wire to the supply white (neutral) wire using wire connector supplied (Figure 9). Securely connect the fan motor black wire and blue wire to the supply black (hot) wire using wire connector supplied (Figure 9). After connections have been made, turn leads upward and carefully push leads into the outlet box, with the white and green leads on one side of the outlet box and the black and blue leads on the other side of the outlet box.

6

then slide the reversing switch to opposite position,

and turn fan on again. The fan blades will turn in

the opposite direction and reverse the airflow.

Your fan model is equipped with a 4-position,

3-speed pull chain switch. The operating sequence

is as follows:

THREE-SPEED

1st Pull—HIGH 2nd Pull—Medium 3rd Pull—Low

4th Pull—OFF

REVERSING

SPEED

 

SWITCH

CONTROL

 

SWITCH

 

 

Page 6
Image 6
Emerson CF796CW0, CF796HGMO0, CF796MP0 warranty How to Wire Your Ceiling Fan, Using Your Ceiling Fan, Three-Speed