PLASTIC WASHER (3)

!WARNING

To reduce the risk of personal injury, do not bend the blade flange when installing the blade flanges, bal- ancing the blades or cleaning the fan. Do not insert foreign objects in between rotating fan blades.

3/16-24 x 3/8" SLOTTED PHILLIPS HEAD SCREW (3)

FELT WASHER (3)

 

FAN BLADE

Figure 5

BLADE FLANGE

8.Turn the fan assembly upside down in preparation for mounting the fan blade assemblies.

NOTE: Take care not to scratch fan housing when installing blades.

9.Rotate the motor hub until the flange screw hole is visible through one of the slots in the switch hous- ing plate. Loosely attach one blade assembly to the motor hub using two 1/4-20 x 7/16” Phillips oval head flange screws (Figure 6). Make sure the screws are NOT tightened. Repeat this procedure for the other four blade assemblies.

10.The blade flanges have an interlocking feature that must be fully engaged before tightening the screws. Make sure all the flanges are properly engaged and then tighten the flange screws. If one of the flanges does not seat properly on the motor hub, loosen the adjacent flange screws, re-engage and reseat the flanges, then tighten the screws

again.

 

BLADE

SWITCH HOUSING

FLANGE

PLATE

 

1/4-20 x 7/16" PHILLIPS OVAL HEAD FLANGE SCREWS (INSTALL THROUGH SLOT IN SWITCH HOUSING PLATE)

MOTOR HUB

Figure 6

SWITCH

HOUSING

ASSEMBLY

SWITCH HOUSING

ASSEMBLY

MOTOR

CONNECTOR

Figure 7

12.Remove the four mounting screws from the switch housing plate. Attach the switch housing to the switch housing plate using the four mounting screws.

NOTE: Do not pinch wires between the switch housing assembly and the switch housing plate.

SWITCH HOUSING

ASSEMBLY

MOUNTING

SCREWS (4)

Figure 8

13.You have now completed the assembly of your new ceiling fan. You can now proceed with hang- ing and wiring your fan.

Electrical Requirements

Your new ceiling fan will require a grounded electrical supply line of 120 volts AC, 60 Hz, 15 amp circuit.

!WARNING

To reduce the risk of fire, electric shock, or personal injury, mount fan to outlet box marked acceptable for fan support, and use screws supplied with outlet box. Most outlet boxes commonly used for support of light fixtures are not acceptable for fan support and may need to be replaced. Consult a qualified electrician if in doubt.

11.Engage the connector of the switch housing assembly with the motor connector (Figure 7). The two connectors are keyed and color-coded and must be mated correctly (color-to-color) before they can be engaged. Make sure the con- nector latch closes properly.

The outlet box must be securely anchored and capa- ble of withstanding a load of at least 50 pounds.

If your fan is to replace an existing ceiling light fixture, turn electricity off at the main fuse box at this time and remove the existing light fixture.

5

!WARNING

To avoid fire or shock, follow all wiring instructions carefully.

Any electrical work not described in these instructions should be done or approved by a licensed electrician.

Page 5
Image 5
Emerson CF942HTW00, CF942OB00, CF942TG00, CF942SB00, CF942WB00, CF942BS00 warranty Electrical Requirements

CF942TG00, CF942SB00, CF942OB00, CF942BS00, CF942HTW00 specifications

The Emerson CF942 series of ceiling fans consists of various models, including CF942WB00, CF942HTW00, CF942BS00, CF942OB00, and CF942SB00. These fans are renowned for their elegant designs, energy efficiency, and cutting-edge features, making them an ideal choice for enhancing the comfort and aesthetics of any living space.

One of the main features of the CF942 series is its innovative motor technology. The fans are equipped with powerful and efficient motors that ensure quiet operation while providing optimal airflow. This makes them suitable for bedrooms, living rooms, and even larger spaces where comfort is essential. The motors also contribute to extended durability, reducing the need for maintenance over time.

Another characteristic of the Emerson CF942 series is the variety of finish options available. Each model comes in distinct colors, including a sleek white (CF942HTW00), a rich bronze (CF942BS00), an elegant oil-rubbed bronze (CF942OB00), and a classic black (CF942SB00). This diverse range of finishes allows homeowners to select a fan that seamlessly blends into their decor, whether it be modern, traditional, or rustic.

In terms of size, the CF942 fans are designed to fit various room dimensions, making them versatile options for different applications. The streamlined design of the blades ensures maximum airflow efficiency while maintaining a stylish appearance. Additionally, the fans often come with a standard downrod for easy installation and can be mounted on flat or angled ceilings, providing flexibility.

The CF942 models also typically feature a convenient remote control, allowing users to adjust fan speed and lighting effortlessly from anywhere in the room. Some models may include integrated LED lighting, which further enhances their appeal by providing both illumination and energy savings.

Installation is straightforward, and the user-friendly design ensures that even those with minimal DIY skills can set up their new ceiling fan with ease. Overall, the Emerson CF942 series combines functionality, style, and technology to create ceiling fans that are perfect for enhancing the comfort of any home environment. With a focus on quality and efficiency, these fans are an investment that will provide lasting satisfaction for years to come.