Emerson HF1160BS 00, HF1160WW 00, HF1160BK 00 Electrical Requirements, Assembly Instructions

Models: HF1160BK 00 HF1160WW 00 HF1160BS 00

1 8
Download 8 pages 18.27 Kb
Page 3
Image 3
1-800-654-3545

WARNING

Do not install or use fan if any part is damaged or missing. Call Toll-Free:

1-800-654-3545

WARNING

This product is designed to use only those parts supplied with this product and/or any accessories designated specifically for use with this product by Emerson Electric Co. Substitution of parts or accessories not designated for use with this product by Emerson Electric Co. could result in personal injury or property damage.

Electrical Requirements

Your new ceiling fan will require a grounded electrical supply line of 120 volts AC, 60 Hz, 15 amp circuit.

The outlet box must be securely anchored and capable of withstanding a load of at least 50 pounds.

WARNING

To reduce the risk of fire, electric shock, or personal injury, mount fan to outlet box marked “Acceptable for Fan Support of 50 lbs. or less”, and use screws supplied with outlet box. Most outlet boxes commonly used for support of light fixtures are not acceptable for fan support and may need to be replaced. Consult a qualified electrician if in doubt.

If your fan is to replace an existing ceiling light fixture, turn electricity off at the main fuse box at this time and remove the existing light fixture.

WARNING

Turning off wall switch is not sufficient. To avoid possible electrical shock, be sure electricity is turned off at the main fuse box before wiring. All wiring must be in accordance with National and Local codes and the ceiling fan must be properly grounded as a precaution against possible electrical shock.

Assembly Instructions

CAUTION: The blade assemblies must be mounted on the motor assembly so that the “This Side Up” label is visible at the top of the motor (Figure 1).

1.Install one blade assembly on the top of the motor assembly using two M6-1.0 x 12mm Phillips hex head screws, two split lockwashers and two flat washers (supplied) (Figure 1). Repeat this procedure for the remaining two blade assemblies.

M6-1.0 x 12mm PHILLIPS

HEX HEAD SCREW

SPLIT LOCKWASHER

SETSCREW (2)

FLAT WASHER

 

BLADE

MOTOR

YOKE

ASSEMBLY

 

LABEL

 

MOTOR ASSEMBLY Electrical Requirements

3 Figure 1

U.L. Model No.: HF1160

Page 3
Image 3
Emerson HF1160BS 00, HF1160WW 00, HF1160BK 00 warranty Electrical Requirements, Assembly Instructions