GB Instructions specific to hazardous area installations

General:

1.Installation of this equipment shall be carried out by suitably trained personnel, in accordance with the applicable code of practice.

2.The apparatus electronics is only certified for use in ambient temperatures in the range of -40ºC to +85ºC for T4. It should not be used outside this range.

3.If the equipment is likely to come into contact with aggressive substances, it is the responsibility of the user to take suitable precautions that prevent it from being adversely affected, thus ensuring that the type of protection is not compromised.

Aggressive Substances

- e.g. acidic liquids or gases that may attack metals or solvents that may affect

 

polymeric materials.

Suitable Precautions

- e.g. regular checks as part of routine inspections or establishing from the

 

material's data sheet that it is resistant to specific chemicals.

4.Special conditions for safe use:

(a) If the enclosure is made of an alloy or plastic material, the following precautions must be observed:

(i) The metallic alloy used for the enclosure material may be at the accessible surface of this equipment; in the event of rare accidents, ignition sources due to impact and friction sparks could occur. This shall be considered when the Electropulse is being installed in locations that specifically require group II, category 1G equipment.

(ii) Under certain extreme circumstances, the non-metallic parts incorporated in the enclosure of the Electropulse may generate an ignition-capable level of electrostatic charge. Therefore, when they are used for applications that specifically require group II, category 1 equipment, the Electropulse shall not be installed in a location where the external conditions are conducive to the build-up of electrostatic charge on such surfaces. Additionally, the Electropulse shall only be cleaned with a damp cloth.

Sensors:

Model numbers covered: ***S*U*H*** ('*' indicates options in construction, function and materials.) The following instructions apply to equipment covered by certificate number TRL 03ATEX21023X:

5.The equipment may be used with flammable gases and vapours with apparatus groups IIA, IIB & IIC, and with temperature classes T1, T2, T3, T4 & T5. Note: The enclosure may be at the higher of the process or ambient temperature

6.The equipment is not intended to be repaired by the user and is to be replaced by an equivalent certified unit. Repairs should only be carried out by the manufacturer or approved repairer.

7.The cable screen may have been internally connected to the metal housing of the equipment.

8.Technical Data:

(a) Materials of construction: Refer to Part numbering identification chart.

(b) Coding:

II 1 G,

T4 (-40°C Ta +85°C)

 

EEx ia IIC

 

 

T5 (-40°C Ta +40°C)

(c) Electrical:

Input parameters: Ui: +16.27V, Ii: 205mA, Pi: 0.63W, Ci: 8nF, Li: 0µH.

(d) Pressure: Must not exceed the rating of the coupling/flange fitted.

9.Special conditions for safe use:

(a) The sensor may not meet the requirements of EN50020: 2002 clause 6.4.12 (Isolation of circuits from earth or frame). Therefore the sensor shall only be connected via a galvanically isolated source, or an adjacent amplifier as described below.

(b) The sensor when used in ATEX applications shall only be connected to an Adjacent Amplifier certified under EC type examination certificate TRL03ATEX21033X or TRL03ATEX21035X.

(c) The sensor shall be installed such that it shall not exceed the Class 3M8/4M8 level of vibration as defined by IEC60721.

Page 2

IP221/SI

Page 2
Image 2
Emerson IP221/SI manual General, Sensors

IP221/SI specifications

The Emerson IP221/SI is an intelligent process control solution designed to meet the rigorous demands of various industrial applications. Known for its unique blend of flexibility, robustness, and advanced technology, this product serves as a powerful tool for process automation and monitoring.

At the core of the IP221/SI’s appeal is its versatility. It comes equipped with multiple I/O options that allow for seamless integration into existing systems, facilitating both analog and digital input and output configurations. This feature is particularly beneficial for industries that require adaptable solutions to match their specific operational needs.

One of the standout characteristics of the IP221/SI is its use of sophisticated communication protocols. It supports multiple fieldbus options, including MODBUS and Ethernet/IP, ensuring reliable data exchange between devices across different networks. This connectivity supports real-time monitoring and control, allowing for swift decision-making and enhanced operational efficiency.

The IP221/SI is designed with advanced processing capabilities that enable complex calculations and data handling. This includes features for trending, alarming, and reporting, which can be customized to fit the end-user’s requirements. The intelligent algorithms embedded in the device help optimize performance and reduce the likelihood of failures by predicting maintenance needs.

Another key feature is its user-friendly interface. The device provides intuitive configuration options and diagnostics that simplify setup and operational monitoring. Moreover, the IP221/SI is equipped with a graphical display that facilitates easy navigation through various operational parameters and settings.

Durability and reliability are paramount in industrial environments, and the Emerson IP221/SI excels in this regard. Built to withstand harsh conditions, it is resistant to vibrations, temperature fluctuations, and exposure to corrosive elements. This makes it an ideal choice for applications in sectors such as oil and gas, water and wastewater, food and beverage, and chemical processing.

In summary, the Emerson IP221/SI is a robust and intelligent process control solution featuring versatile I/O options, advanced communication protocols, and powerful processing capabilities. Its user-friendly design, coupled with exceptional durability, positions it as a reliable choice for organizations seeking to enhance their automation processes and improve overall operational efficiency.