BP7283, High Country, KF160 7/31/06 10:54 AM Page 3

This Manual Is Designed to Make it as Easy as Possible for You to

Assemble, Install, Operate and Maintain Your Ceiling Fan

Tools Needed for Assembly

One Phillips head screwdriver One wire stripper

One stepladder

Six wire connectors (supplied)

Three 60-watt (max.) candelabra base bulbs Three 40-watt (max.) cnadelabra

base round bulbs

Materials

Wiring, outlet box and box connectors must be of type required by the local code. The minimum wire would be a 3-conductor (2-wire with ground) of the following sizes:

Installed Wire Length

Wire Size A.W.G.

Up to 50 ft.

14

50-100 ft.

12

 

 

Unpacking Instructions

For your convenience, check-off boxes are provided next to each step. As each step is completed, place a check mark in the box. This will insure that all steps have been completed and will be helpful in finding your place should you be interrupted.

!WARNING

Do not install or use fan if any part is damaged or missing. Call Toll-Free:

1-800-654-3545

!WARNING

This product is designed to use only those parts supplied with this product and/or any accessories designated specifically for use with this product by Emerson Electric Co. Substitution of parts or accessories not designated for use with this product by Emerson Electric Co. could result in personal injury or property damage.

1. Open styrofoam unit containing fan. Remove top half of styrofoam unit. Remove parts and check to see that you have received the following parts:

NOTE: If you are uncertain of part description, refer to exploded view illustration.

a.Fan motor housing assembly

b.One upper glass

c.One ceiling cover

d.One decorative cover

e.Five fan blades

f.Five blade flanges

g.One hanger bracket

h.One hanger ball/downrod assembly

i.One 3-1/2” downrod

j.One decorative cap

k.One finial nut

l.One lower glass

m.One decorative scroll assembly

n.One light fitter adapter

o.One light fitter assembly

p.One remote control transmitter

q.One remote control receiver

r.One loose parts bag, containing:

1.Two 1-1/4” threaded studs

2.Two knurled knobs

3.Two lockwashers

4.Seven wire connectors

5.One hairpin clip

6.One clevis pin

7.Eleven 1/4-20 x 11mm pan head screws with lockwashers

8.Sixteen 10-24 x 9mm truss head screws

9.Sixteen fiber washers

10.Four 8-32 x 12mm pan head screws

11.Three 8-32 x 15mm pan head screws

12.Three #8 flat washers

13.Three #8 rubber washers

14.One nut 1/8 - 27NPS

15.One lockwasher 1/8 - 27NPS

NOTE: Place the parts from the loose parts bags in a small container to keep them from being lost. If any parts are missing, contact your local retailer or catalog outlet for replacement before proceeding.

 

UP DN

 

HIGH

 

MED

e

LOW

OFF

REV

 

 

 

 

 

 

 

p

 

 

b

j

 

 

l

 

 

 

f

 

 

o

 

 

 

 

k

m

 

 

 

h

 

n

q

 

 

 

 

 

 

 

 

 

a

 

c

 

i

 

 

r

 

d

g

 

 

3

 

 

 

 

 

 

 

 

 

 

 

 

Page 3
Image 3
Emerson KF160OI01 owner manual Materials

KF160OI01 specifications

The Emerson KF160OI01 is a cutting-edge cooling solution designed for commercial and industrial applications, boasting a range of features that cater to efficiency, reliability, and ease of use. One of the standout aspects of this unit is its advanced refrigerant technology, which utilizes eco-friendly refrigerants to reduce environmental impact while maximizing cooling performance.

At its core, the KF160OI01 is engineered with a high-efficiency compressor that operates quietly and effectively, ensuring optimal performance while keeping energy costs low. This compressor is paired with a high-capacity condenser coil that enhances heat exchange capabilities, allowing the unit to cool large spaces quickly and effectively. This makes the KF160OI01 ideal for environments that require rapid temperature control, such as restaurants, warehouses, and manufacturing facilities.

Additionally, the Emerson KF160OI01 incorporates intelligent control systems that allow for precise temperature regulation. These smart controls enable users to set specific temperature thresholds and monitor energy consumption, enhancing overall operational efficiency. The inclusion of a digital display and user-friendly interface further simplifies the monitoring and adjustment of settings, making it easy for operators to maintain optimal conditions.

Durability is another significant characteristic of the KF160OI01. The unit is built with robust materials designed to withstand the rigors of continuous operation in demanding environments. This longevity is complemented by a built-in self-diagnostic feature that alerts users to any potential issues before they escalate, minimizing downtime and maintenance costs.

Furthermore, the KF160OI01 is designed with flexibility in mind. Its modular construction allows for easy integration into existing systems or replacement of older units. This adaptability ensures that it can meet a variety of installation requirements while providing consistent performance.

In summary, the Emerson KF160OI01 represents a pinnacle of innovation in commercial cooling technology. With its focus on energy efficiency, advanced controls, and durability, it stands out as a reliable solution for businesses looking to enhance their environmental comfort while minimizing costs and energy consumption. As industries increasingly prioritize sustainable practices, the KF160OI01 is poised to meet future demands, making it a wise investment for any commercial operation.