Emerson KF160OI01 owner manual How to Wire Your Ceiling Fan

Models: KF160OI01

1 16
Download 16 pages 44.6 Kb
Page 9
Image 9
How to Wire Your Ceiling Fan

BP7283, High Country, KF160 7/31/06 10:54 AM Page 9

How to Wire Your Ceiling Fan

Manual backgroundManual background 2. Refer to Figure 12 and 13 and connect the receiver wires to the supply wires and the fan motor wires as follows:

If you feel that you do not have enough electrical wiring knowledge or experi- ence, have your fan installed by a licensed electrician.

!WARNING

Turning off wall switch is not suffi- cient. To avoid possible electrical shock, be sure electricity is turned off at the main fuse or circuit breaker box before wiring. All wiring must be in accordance with National and Local codes and the ceiling fan must be properly grounded as a precau- tion against possible electrical shock.

CAUTION: To reduce the risk of electri- cal shock, disconnect the electrical supply circuit before installing the fan, light kit or receiver.

Manual backgroundManual background 1. Position the supply wires to the left side of the outlet box (Figure 12); position the fan wires to the right side. Partially insert the remote control receiver (flat side up) until one end rests on the hanger ball as shown in Figure 12.

NOTE: Make all wiring connections using wire connectors (supplied). Make sure that all connections are tight, including ground, and that no bare wire is visible at the wire connectors, except for the ground wire.

a.Securely connect the green grounding wires from the hanger ball and the hanger bracket to the supply grounding conductor (this may be a bare wire or a wire with green insulation).

b.Securely connect the supply white (neutral) wire to the receiver white (AC IN N) wire.

c.Securely connect the supply black wire (hot) wire to the receiver black (AC IN

L)wire.

d.Securely connect the fan motor white wire to the receiver white (TO MOTOR

N)wire.

e.Securely connect the fan motor black wire to the receiver black (TO MOTOR

L)wire.

f.Securely connect the fan motor blue wire to the receiver blue (FOR BOTTOM LIGHT) wire.

g.Securely connect the fan motor orange wire to the receiver orange (FOR UPPER LIGHT) wire.

!WARNING

Check to see that all connections are tight, including ground, and that no bare wire is visible at the wire con- nectors, except for the ground wire. Do not operate fan until blades are in place. Noise and fan damage could result.

 

SUPPLY WHITE WIRE

 

(NEUTRAL)

 

SUPPLY BLACK

A

 

 

C I

 

WIRE (HOT)

N

N

 

GROUND WIRE

 

 

GREEN GROUND WIRE

 

AC IN L

 

 

FROM HANGER BALL

 

 

ANTENNA

 

 

GREEN GROUND WIRE

 

FAN BLACK

FROM HANGER BRACKET

 

WIRE

1-1/4" THREADED

FAN BLUE WIRE

STUD (2)

FAN WHITE WIRE

Figure 12

RECEIVER WHITE

WIRE

RECEIVER BLACK WIRE

RECEIVER BLACK

WIRE

RECEIVER

BLUE WIRE

 

 

LIGHT

 

MOTOR

L

 

LIGHT

MOTOR

N

BOTTOM

 

 

UPPER

 

 

TO

 

FOR

RECEIVER

 

 

 

TO

 

FOR

 

 

 

ORANGE WIRE

FAN ORANGE

WIRE

RECEIVER WHITE

WIRE

9

Page 9
Image 9
Emerson KF160OI01 owner manual How to Wire Your Ceiling Fan