Emerson Specifications, Remote Power Monitor Panel RPMP, M o n i t o r i n g S e r v i c e

Models: Remote Power Monitor Panel

1 2
Download 2 pages 42.39 Kb
Page 2
Image 2
Specifications

Remote Power Monitor Panel (RPMP)

M o n i t o r i n g S e r v i c e

Specifications

 

 

The unit front monitoring panel

Dimensions (WxHxD)

20" x 20" x 8"

displays up to 4 lines of text, with up

 

(50.8 cm x 50.8 cm x 20.32)

 

 

to 20 characters per line. The large

Weight

48 lbs. (21 kg)

viewing area allows easy monitoring

 

 

Operating Environment

32 – 104˚F (0-40˚C)

of complete information.

 

 

 

 

L I E B E R T C O R P O R A T I O N

1050 DEARBORN DRIVE

P.O. BOX 29186

COLUMBUS, OHIO 43229

800.877.9222 PHONE (U.S. &

CANADA ONLY)

614.888.0246 PHONE (OUTSIDE U.S.) 614.841.6022 FAX

VIA LEONARDO DA VINCI 8

ZONA INDUSTRIALE TOGNANA

35028 PIOVE DI SACCO (PD)

ITALY

39 049 9719 111 PHONE

39 049 5841 257 FAX

23/F ALLIED KAJIMA BLDG.

138 GLOUCESTER ROAD

WANCHAI

HONG KONG

Monitored Parameters:

Input Voltage (L-L)

Output Voltage (L-L, L-N)

Output Current

Output Neutral

Ground Current

Output Frequency

Output kVA

Output Kilowatts

Output Power Factor

Output Percent Load

Alarms:

Output Overvoltage

Frequency Deviation

Phase Sequence Error

Phase Loss

Output Undervoltage

Output Overcurrent

Neutral Overcurrent

Ground Overcurrent

Up To Four Normally Open Contact Closures

One Normally Closed Contact Closure

One Normally Open Form C Summary Alarm Contact

One Normally Closed Form C Summary Alarm Contact

True Rms Monitoring.

Accurate representation of non-sinusoidal waveforms typical of computers and other sensitive loads.

Emergency Power Off.

When selected, the lighted, covered switch, will immediately power down the connected equipment by activating a shunt trip of the main input breaker (if the system is equipped with shunt trip capabilities).

Adjustable Alarm Threshold.

Adjusted using the RS-232-C service port. Adjustable parameters include: Output overvoltage, undervoltage, and overcurrent; Neutral overcurrent; Ground overcurrent; and Frequency deviation.

Field Programmable Custom Alarms.

Up to four normally open and one normally closed custom alarms are available. A custom alarm message of up to 20 characters is available for each alarm, programmable through the RS-232-C port.

Summary Alarms.

Form C summary alarm contact (one normally open, one normally closed) are provided.

Battery-Backed Alarms.

Alarm parameters are battery backed to prevent loss in case of a power outage.

Eia-422-A Communication Port.

Reliable communication up to 1000 meters.

Eia-232-C Service Port.

Allows for parameter adjustment.

Local And Centralized Monitoring.

Monitored parameters and alarms are displayed locally on the RPMP monitor panel. The RPMP can also communicate with the Liebert SiteScan Centralized Monitoring system, providing convenient monitoring and control for all your critical application needs.

852 2 572 2201 PHONE

852 2 831 0114 FAX

L I E B E R T W E B S I T E

http://www.liebert.com

2 4 X 7 T E C H S U P P O R T

800 222 5877 PHONE

614 841 6755 (OUTSIDE U.S.)

While every precaution has been taken to ensure accuracy and completeness in this literature, Liebert Corporation assumes no responsibility, and disclaims all liability for damages resulting from use of this information or for any errors or omissions.

©2002 Liebert Corporation. All rights reserved throughout the world. Specifications subject to change without notice.

All names referred to are trademarks or registered trademarks of their respective owners.

®Liebert and the Liebert logo are registered trademarks of the Liebert Corporation.

®Keeping Business in Business is a registered trademark of the Liebert Corporation.

The Emerson logo is a trademark and service mark of Emerson Electric Co.

SL-31040 (R5/02)

Printed in USA

www.liebert.com

Page 2
Image 2
Emerson Specifications, Remote Power Monitor Panel RPMP, M o n i t o r i n g S e r v i c e, of complete information