Hazardous area classifications

Hazardous area classifications

UL is a U.S.A. approvals agency. CSA is a Canadian approvals agency that provides approvals accepted in both the U.S.A. (C-US) and Canada. ATEX is a European directive.

UL and CSA

Model 3300

Class I, Div. 2, Groups A, B, C, and D when installed in a suitable

 

 

enclosure

 

 

Model 3350

Class I, Div. 2, Groups A, B, C, and D

 

Model 3500

Class I, Div. 2, Groups A, B, C, and D when installed in a suitable

 

 

enclosure

 

 

 

Provides non-incendive sensor outputs for use in Class I, Div. 2,

 

 

Groups A, B, C, and D, or intrinsically safe sensor outputs for use

 

 

in Class I, Div. 1, Groups C and D; Class II, Div. 1, Groups E, F,

 

 

and G

 

 

Model 3700

Class I, Div. 2, Groups A, B, C, and D

 

 

Provides non-incendive sensor outputs for use in Class I, Div. 2,

 

 

Groups A, B, C, and D, or intrinsically safe sensor outputs for use

 

 

in Class I, Div. 1, Groups C and D; Class II, Div. 1, Groups E, F,

 

 

and G

 

ATEX

Model 3350

ATEX Zone 1

 

 

 

CE 0575

II 2G EEx de [ib] IIB/IIC T4

 

Model 3500

Safe area only. Can be connected to a sensor in ATEX Zone 1

 

 

area.

 

 

 

CE 0575

II (2)G [EEx ib] IIB/IIC

 

Model 3700

ATEX Zone 1

 

 

 

CE 0575

II 2G EEx de [ib] IIB/IIC T4

 

 

 

 

Micro Motion® Series 3000 Transmitters and Discrete Controllers

9

Page 9
Image 9
Emerson Series 3000 manual Hazardous area classifications, UL and CSA, Atex