UL is a U.S.A. approvals agency. CSA is a Canadian approvals agency that provides approvals accepted in both the U.S.A.
UL and CSA | Model 3300 | Class I, Div. 2, Groups A, B, C, and D when installed in a suitable | |
|
| enclosure |
|
| Model 3350 | Class I, Div. 2, Groups A, B, C, and D | |
| Model 3500 | Class I, Div. 2, Groups A, B, C, and D when installed in a suitable | |
|
| enclosure |
|
|
| Provides | |
|
| Groups A, B, C, and D, or intrinsically safe sensor outputs for use | |
|
| in Class I, Div. 1, Groups C and D; Class II, Div. 1, Groups E, F, | |
|
| and G |
|
| Model 3700 | Class I, Div. 2, Groups A, B, C, and D | |
|
| Provides | |
|
| Groups A, B, C, and D, or intrinsically safe sensor outputs for use | |
|
| in Class I, Div. 1, Groups C and D; Class II, Div. 1, Groups E, F, | |
|
| and G |
|
ATEX | Model 3350 | ATEX Zone 1 |
|
|
| CE 0575 | II 2G EEx de [ib] IIB/IIC T4 |
| Model 3500 | Safe area only. Can be connected to a sensor in ATEX Zone 1 | |
|
| area. |
|
|
| CE 0575 | II (2)G [EEx ib] IIB/IIC |
| Model 3700 | ATEX Zone 1 |
|
|
| CE 0575 | II 2G EEx de [ib] IIB/IIC T4 |
|
|
|
|
Micro Motion® Series 3000 Transmitters and Discrete Controllers | 9 |