Emerson Series 3000 Model 3100 accessory, Model 3500/3700 liquid flow performance, Relays module

Models: Series 3000

1 28
Download 28 pages 54.72 Kb
Page 10
Image 10
Model 3100 accessory

Model 3100 accessory

Relays module

Three relays

 

Solid state, SPST

 

Rated at 24–250 VAC, 40 mA to 5 A; or 0–70 VDC, 5 A

 

Energized by discrete outputs

 

NEMA 4X (IP65) enclosure (optional)

UL and CSA approvals

Class I, Div. 2, Groups A, B, C, and D

ATEX approvals

Suitable for installation in Zone 2, when properly installed in a suitable enclosure, complying with

 

ATEX Directive (94/9/EC) for Group II, Category 3G, according to CENELEC standard EN 50021

 

(1998) and marked as:

 

EEx n V II T4

 

KEMA 97 ATEX4940X

 

Ambient temperature –20 to +60 °C (–4 to +140 °F)

 

Additional installation-specific requirements are described in detail in the Series 3000 instruction

 

manual.

 

 

Model 3500/3700 liquid flow performance

Mass flow accuracy(1)(2)

Volume flow accuracy(1) (2)

Repeatability(2)

Sensor model

 

ELITE®

±0.05% of rate

F-Series

±0.10% of rate

H-Series

±0.10% of rate

T-Series

±0.15% of rate

R-Series

±0.50% of rate

ELITE

±0.05% of rate

F-Series

±0.15% of rate

H-Series

±0.15% of rate

T-Series

±0.25% of rate

R-Series

±0.50% of rate

ELITE

±0.025% of rate

F-Series

±0.05% of rate

H-Series

±0.05% of rate

T-Series

±0.05% of rate

R-Series

±0.25% of rate

(1)Stated flow accuracy includes the combined effects of repeatability, linearity, and hysteresis.

(2)For the details of flow accuracy and repeatability specifications, refer to the product data sheet for each sensor family.

10Micro Motion® Series 3000 Transmitters and Discrete Controllers

Page 10
Image 10
Emerson Series 3000 Model 3100 accessory, Model 3500/3700 liquid flow performance, Relays module, UL and CSA approvals