BASIC SST SERVICE GUIDE

BASIC SST SERVICE GUIDE

This guide will cover most homeowner complaints. If, after checking the items listed, the unit still fails to operate properly, contact the nearest Authorized Service Center.

SERVICE INDICATION

 

SERVICE CHECKS

 

 

ON/OFF switch “ON”

Unit functioning Normally

Blower ON

 

 

Operating Light ON

 

 

 

 

 

ON/OFF switch “ON”

1.

Power is not being supplied to air cleaner.

Blower ON

 

A. Check fuse or circuit breaker.

Operating Light OFF

 

B. Ensure power pack is properly installed and latched.

 

2.

Collecting cell shorted - Turn power Off - Remove power pack - Remove

 

 

collecting cells - Replace power pack - Restore power (ensure blower is

 

 

operating).

 

 

A. If Operating Light comes ON check cells for bent plates, loose ionizing

 

 

wire(s) or cracked insulator(s).

 

 

B. If Operating Light remains OFF, malfunction is in the power pack. (See

 

 

power supply Checkout Procedure).

 

 

 

ON/OFF Switch “ON”

1.

Air flow sensor contaminated/misaligned

Blower OFF

 

A. Remove power pack and clear contamination inside black bushing around

Operating Light ON

 

the small sensor element.

 

 

B. Ensure small sensor element is centered in bushing.

 

2.

Air sensor left in bypassed condition after servicing.**

 

3.

Faulty air flow sensor panel.

 

 

 

Excessive arcing during

1.

Wet collecting cell.

normal operation -

 

A. Allow cell(s) to dry after cleaning before applying power.

Operating Light may blink

2.

Damaged collecting cell(s).

 

 

A. Remove cell(s) and inspect for bent plates, loose ionizing wire(s), cracked

 

 

insulator(s), etc.

 

3.

Collecting cells dirty.

 

 

A. Clean cells as instructed in this manual.

 

4.

Faulty power supply (see power supply checkout procedure)

 

 

 

**NOTE: Your air cleaner may be equipped with an air flow sensor (switch) which turns the unit ON and OFF in response to the system blower. It may have been “wired out” during a service check and inadvertently left in this condition.

10

Page 10
Image 10
Emerson SST1400, SST1000, SST2000, SST1600 manual Basic Sst Service Guide, Service Indication, Service Checks

FAQ

What should I do if the unit fails to operate properly?

If, after checking the items listed in the service guide, the unit still fails to operate properly, contact the nearest Authorized Service Center.

How do I check if the power is being supplied to the air cleaner?

If the blower is ON but the operating light is OFF, check the fuse or circuit breaker, and ensure the power pack is properly installed and latched.

What should I do if there is excessive arcing during normal operation?

If the operating light may blink due to excessive arcing, allow the collecting cells to dry after cleaning before applying power. Inspect the cells for any damage or dirt.