Emerson SST1000, SST2000, SST1400, SST1600 manual Preinstallation, Locating the AIR Filter

Models: SST1600 SST1400 SST2000 SST1000

1 16
Download 16 pages 8.37 Kb
Page 4
Image 4

PREINSTALLATION

Not to Exceed 20

Air Flow

Furnace

Air Flow

 

Opening

 

 

Electronic

 

Air Cleaner

 

Opening

Furnace

Electronic

Transition Section

Air Cleaner

(if Needed)

 

Figure 3

LOCATING THE AIR FILTER

Your air filter must be mounted in the return air duct of a central forced-air system, on the air entering side of your furnace. (See Figure 3 for example.)

(Interchangeable)

(Interchangeable)

Collecting Cell

Collecting Cell

Cabinet

Outlet Box

Power Pack

 

Handle

Contact

 

 

Button

Contact

 

Pre-Filters

 

Button

 

(Interchangeable)

See text for Cell

 

Removal Clearance

Figure 4

 

Knockouts for

6 7/8"

3/4" Conduit

(three sides)

 

Select a location that meets the following:

1. The face of the cell will be at a right angle to the air

stream.

E

CF

2.

Allow the following clearances to permit removal of

 

cells and pre-filters: (See Figures 4 and 5)

 

Model SST1000 - 14 inches

 

Model SST1400 - 15 inches

 

Model SST1600 - 14 inches

 

Model SST2000 - 15 inches

 

For complete dimension data refer to Figure 5.

3.

The air filter is not to be placed in the discharge of

 

either the heating or cooling unit.

4.

IMPORTANT: If atomizing spray type humidifier is

 

used, it must be installed downstream from the air

 

filter.

5.

If the air cleaner has a power cord installed, unit must

 

be located close enought to the outlet so connection

 

can be made without the use of an extension cord.

If your furnace duct system has a pre-installed boot, discard front cover of boot and slide the air cleaner component inside the boot. For installation of Air Cleaner Retrofit (ACR) kits, see page 13.

If furnace opening cannot be enlarged to required size, a transition sheet metal section must be used. Transition must be planned for each job. Reduction should not be more than 4 inches per linear foot, approximately 20 angular degrees (Figure 3).

D

B

A

MODEL NO.

A

B

C

D

E

F

SST1000

24 3/4

21 5/16

18 5/8

13 9/16

16 7/16

19 1/16

SST1400

29 11/16

26 1/4

23 5/8

13 9/16

16 7/16

19 1/16

SST1600

25 1/2

21 5/16

18 5/8

17 3/4

20 5/8

23 3/8

SST2000

29 11/16

26 1/4

23 5/8

17 3/4

20 5/8

23 3/8

Figure 5

DIRECTION OF AIR FLOW THROUGH

THE AIR CLEANER

Your air cleaner is shipped from the factory with air flow from left-to-right. If this air flow is suitable for the installation, no further changes need to be made (Fig- ure 4). For right-to-left air flow, remove both pre-filter and cell sections. Turn cells upside down (with the same end facing the cabinet opening). This will locate the ionizing wires at the right, and both contact buttons and cell handles will be facing the power door. Air flow direction must agree with arrow embossed on end of collecting cells.

After installing the cell sections, install pre-filters in cabinet tracks on the right. This will again place the pre-filters on the air entering side (on the same side as ionizing wires).

4

Page 4
Image 4
Emerson SST1000, SST2000, SST1400 manual Preinstallation, Locating the AIR Filter, Direction of AIR Flow Through AIR Cleaner

SST1600, SST1400, SST2000, SST1000 specifications

Emerson’s SST series, including the SST1400, SST2000, SST1000, and SST1600, represents a line of advanced technologies designed to meet the demands of modern industrial automation. Each model within the SST series is engineered with unique features that cater to diverse applications while maintaining high performance, reliability, and efficiency.

The SST1400 is designed for medium-scale automation projects. It incorporates a powerful processing unit that ensures fast response times and enhanced processing capabilities. One of the standout features of the SST1400 is its intuitive user interface, which simplifies programming and monitoring tasks. Additionally, it offers extensive connectivity options, allowing seamless integration with a multitude of sensors and devices, thus enabling greater flexibility in application designs.

Next in the lineup is the SST2000, which is tailored for larger and more complex automation systems. The SST2000 boasts a higher processing power compared to its counterparts, supporting real-time data processing and advanced analytics. This model is particularly known for its robust security features, making it a suitable choice for industries where data integrity and protection are paramount. Moreover, the SST2000 supports various communication protocols, ensuring it can connect and communicate with legacy systems as well as modern IoT devices.

The SST1000 is the entry-level model in the series but comes packed with essential features that make it an excellent choice for smaller operations. It provides users with a cost-effective solution without compromising on basic functionalities. The SST1000 includes a range of built-in I/O options and is designed for easy scalability. Its compact design allows it to fit into constrained spaces while still delivering reliable control and monitoring capabilities.

Lastly, the SST1600 is a versatile model that bridges the gap between high performance and user-friendly operation. This system is optimized for mixed-automation environments, supporting various applications through its flexible architecture. With options for customizable modules, the SST1600 can easily adapt to specific operational needs. Key features include an onboard diagnostics system that enhances troubleshooting and maintenance, ensuring minimal downtime.

In conclusion, Emerson’s SST series—encompassing the SST1400, SST2000, SST1000, and SST1600—offers a range of automation solutions catering to various industrial applications. Each model is equipped with distinct features and technologies that collectively enhance performance, connectivity, and operational efficiency. Whether for small-scale or large-scale implementations, the SST series provides the flexibility and reliability required in today's automated environments.