IMPORTANT: To register your Goodman® brand unit, go to www.goodmanmfg.com and click on “Warranty Registration”. Complete registration as prompted.

To register your Amana® brand unit, go to www.amana- hac.com and click “Warranty Registraion”. Complete regis- tration as prompted.

Product limited warranty certificates for models currently in production can be viewed at www.goodmanmfg.com or www.amana-hac.com. If your model is not currently in pro- duction or does not appear on the website, please contact your installing contractor or contact customer service (877- 254-4729) to obtain a copy of your warranty certificate.

Each product overview page contains a Product Warranty link; by clicking on it you will be able to view the limited war- ranty coverage for that specific product. To view warranty reg- istration information, click on the Product Warranty text on the left navigation panel on the home page of each website. The Online Product Registration pages are located in this same section.

Keep this literature in a safe place for future reference.

Shipping Inspection

Always keep the unit upright; laying the unit on its side or top may cause equipment damage. Shipping damage, and sub- sequent investigation is the responsibility of the carrier. Verify the model number, specifications, electrical characteristics, and accessories are correct prior to installation. The distribu- tor or manufacturer will not accept claims from dealers for transportation damage or installation of incorrectly shipped units.

Codes & Regulations

This product is designed and manufactured to comply with national codes. Installation in accordance with such codes and/or prevailing local codes/regulations is the responsibility of the installer. The manufacturer assumes no responsibility for equipment installed in violation of any codes or regula- tions.

The United States Environmental Protection Agency (EPA) has issued various regulations regarding the in- troduction and disposal of refrigerants. Failure to follow these regulations may harm the environment and can lead to the imposition of substantial fines. Should you have any questions please contact the local office of the EPA.

Replacement Parts

When reporting shortages or damages, or ordering repair parts, give the complete product model and serial numbers as stamped on the product. Replacement parts for this prod- uct are available through your contractor or local distributor. For the location of your nearest distributor consult the white business pages, the yellow page section of the local telephone book or contact:

CONSUMER AFFAIRS

GOODMAN MANUFACTURING COMPANY, L.P.

7401 SECURITY WAY

HOUSTON, TEXAS 77040

(877) 254-4729

If replacing an air handler, the system must be manufacturer approved and Air-Conditioning, Heating, and Refrigeration Institute (AHRI) matched. NOTE: Installation of unmatched systems is strongly discouraged.

Pre-Installation Instructions

Carefully read all instructions for the installation prior to in- stalling product. Make sure each step or procedure is under- stood and any special considerations are taken into account before starting installation. Assemble all tools, hardware and supplies needed to complete the installation. Some items may need to be purchased locally. Make sure everything needed to install the product is on hand before starting.

Location

NOTE: Air handlers are designed for indoor installation only.

Give special consideration to minimizing the length of refrig- erant tubing when installing air handlers. Refer to Remote Cooling/Heat Pump Service Manual, TP-107 Long Line Set Application R-410A for guidelines. The unit clearance from a combustible surface may be 0". However, service clearance is to take precedence. In addition allow a minimum of 24" in front of the unit for service clearance.

Do not install the air handler in a location that violates the instructions provided with the condenser.

If the unit is located in an area with high ambient tempera- ture and/or high humidity the air handler maybe subject to nuisance sweating of the casing. On these installations a wrap of 2” fiberglass insulation with a vapor barrier is recom- mended.

Consult all appropriate regulatory codes prior to determining final clearances. When installing this unit in an area that may become wet, elevate the unit with a sturdy, non-porous ma- terial. In installations that may lead to physical damage (i.e. a garage) it is advised to install a protective barrier to pre- vent such damage.

Ductwork

This air handler is designed for a complete supply and re- turn ductwork system.

Do not operate this product without all the ductwork attached.

To ensure correct system performance, the ductwork is to be sized to accommodate 375-425 CFM per ton of cooling with the static pressure not to exceed .5" WC. Inadequate duct work that restricts airflow can result in improper perfor- mance and compressor or heater failure. Ductwork is to be constructed in a manner that limits restrictions and main- tains suitable air velocity. Ductwork is to be sealed to the unit in a manner that will prevent leakage.