ASPF Thermostat Connections
The following composite wiring diagrams detail various con- figurations in which the ASPF air handlers can be used. Ex- amples include
The following sections will be detailed:
•
•Heat Pump
IMPORTANT: WHEN MATCHING THE ASPF AIR HANDLERS TO A SINGLE SPEED COOLING OR HEAT PUMP UNIT, REMEMBER TO CONNECT “Y” FROM THE THERMOSTAT TO THE “Y2” ON THE LOW VOLTAGE TERMINAL BOARD.
An equivalent thermostat can be used in place of the Goodman thermostat part number.
Each diagram details the connections between room ther- mostat and ASPF air handlers, and the connections between the ASPF air handlers and the Condensing Unit (or Heat Pump) with optional connections to Outdoor Thermostats. For each configuration, refer to the explanation of the proper jumper(s) to remove for the corresponding blower speed that will result in the programmed EEM™ motor.
HIGH VOLTAGE! DISCONNECT ALL POWER BEFORE SERVICING. WARNING MULTIPLE POWER SOURCES MAY BE PRESENT. FAILURE TO DO SO MAY CAUSE PROPERTY DAMAGE, PERSONAL INJURY OR DEATH.
#18 GA. 4 WIRES WITH COOLING 3 WIRES WITHOUT
W | Y | G | R |
YL | TO CONDENSING UNIT | |
| ||
| 24V CONNECTION | |
BL | ||
|
RD |
GR |
WH |
YL |
YL |
BL |
TB
C
R
G
W1
W2
Y1
Y2
O
COOLING UNIT WITH OPTIONAL HEAT KITS OF 10 kW AND BELOW
NOTES:
1)OUTDOOR THERMOSTAT
2)JUMPER W1 AND W2 TOGETHER IF
3)REMOVE WIRE WHEN USING OUTDOOR THERMO- STAT.
NOMENCLATURE: | COLOR CODES |
OT - OUTDOOR THERMOSTAT (OPTIONAL) | RD - RED |
EHR - EMERGENCY HEAT RELAY (OPTIONAL) | YL - YELLOW |
| BL - BLUE |
| BR - BROWN |
| OR - ORANGE |
| WH - WHITE |
Wiring is subject to change. Always refer to the wiring diagram on the unit for the most
10