HIGH VOLTAGE! DISCONNECT ALL POWER BEFORE SERVICING. ![]()
WARNING MULTIPLE POWER SOURCES MAY BE PRESENT. FAILURE TO DO SO ![]()
![]()
![]()
![]()
![]()
![]()
![]()
![]()
MAY CAUSE PROPERTY DAMAGE, PERSONAL INJURY OR DEATH. ![]()
![]()
ASPF Wiring Diagram
FL
TL
HTR1
| BK | BK | 1 |
|
| RD | 2 |
|
|
| |
BK | PU |
| 3 |
BL |
|
| |
|
|
| |
| M1 |
| 4 |
|
|
| |
| R |
| 5 |
| M2 |
| |
|
|
| |
| WH |
| 6 |
| BK |
| 7 |
| BK |
|
|
| RD |
| 8 |
FL |
| |
HTR1 | TL | |
| ||
FL |
| |
HTR2 | TL | |
BK | ||
|
|
| RD | BK | 1 |
|
|
| RD | 2 |
|
|
|
| |
RD |
| PU |
| 3 |
| BL |
|
| |
BK | M1 | M3 |
| 4 |
|
|
| ||
| R |
|
| 5 |
| M2 | M4 |
| |
|
|
| ||
|
| WH |
| 6 |
| BK |
|
|
|
| RD |
|
| 7 |
| BK |
|
|
|
|
| RD |
| 8 |
|
|
|
|
| FL |
|
|
|
|
|
|
| HTR1 |
| TL |
|
|
| FL |
|
|
|
| |
|
|
| TL |
|
| |
|
| HTR2 |
|
|
| |
|
|
| RD |
|
| |
|
| HTR3 |
| TL |
|
|
|
|
|
|
|
| |
|
|
|
|
| BK | 1 |
|
| RD | YL |
| 2 | |
|
| PU |
| |||
| YL |
|
| |||
| BK |
|
|
| ||
|
| BL |
| 3 | ||
|
|
|
|
| ||
|
| M1 | M3 | M1 | RD |
|
|
| BL | 4 | |||
RD |
|
|
|
| ||
| M2 | M4 | M2 |
|
| |
|
|
| R1 | R2 | BR | 5 |
BK | BK |
|
|
|
| |
| RD |
|
| WH | 6 | |
|
|
|
| |||
|
|
|
|
|
| 7 |
|
|
| YL |
|
| 8 |
|
|
|
|
|
| |
|
|
|
| BK |
|
|
|
|
| RD |
|
| 9 |
FL |
|
|
| TL |
|
| |
| HTR1 |
|
|
|
| ||
FL |
|
|
|
|
| ||
|
|
| TL |
|
| ||
| HTR2 |
|
|
|
| ||
|
|
|
|
|
| ||
| HTR3 |
|
| TL |
|
| |
|
|
|
|
|
| ||
| HTR4 |
|
| TL |
|
| |
|
|
| BL |
|
| ||
|
|
|
|
| BK | 1 | |
|
|
| PU |
|
| 2 | |
BL | BK RD |
|
|
| |||
| BL |
| 3 | ||||
YL | M1 | M3 | M5 | M7 | RD |
| |
BL | 4 | ||||||
|
|
|
| ||||
RD | M2 | M4 | M6 | M8 |
|
| |
BK | R1 | R2 | BR | 5 | |||
|
|
|
|
| |||
BK | RD |
|
|
| WH | 6 | |
|
|
|
| ||||
|
|
|
|
|
| 7 | |
|
| YL | BL |
|
| 8 | |
|
|
|
|
| |||
|
|
| BK |
|
|
| |
|
| RD |
|
|
| 9 | |
9
9
L1 L2
L1 L2
L1 L2 L1 L2
L1 L2 L1 L2
ONE (1) ELEMENT ROWS
TWO (2) ELEMENT ROWS
THREE (3) ELEMENT ROWS
FOUR (4) ELEMENT ROWS
NOTE: WHEN INSTALLING HEATER KIT, ENSURE SPEED TAP DOES NOT EXCEED MINIMUM BLOWER SPEED (MBS) SPECIFIED FOR THE AIRHANDLER/HEATER
KIT COMBINATION ON THIS UNIT'S S&R PLATE. AFTER INSTALLING OPTIONAL HEAT KIT, MARK A "X" IN THE ![]()
PROVIDED ABOVE. MARK ACCORDING TO NUMBER OF HEATER ELEMENT ROWS INST ALLED. NO MARK INDICATES NO HEAT KIT INSTALLED.
SEE NOTE 2 |
| GRD |
|
|
| EQUIPMENT GROUND |
| ||
|
|
|
|
| USE COPPER WIRE |
| |||
R C G W1 W2 Y1 Y2 O DH 1 2 3 4 5 | L1 | L2 |
|
|
|
|
|
|
|
PLM | 1 | 2 | 3 | 4 | 5 | 6 | 7 | 8 | 9 |
RD |
|
|
|
|
|
|
|
|
|
PLF | 1 | 2 | 3 | 4 | 5 | 6 | 7 | 8 | 9 |
GR | BK | RD |
| BL | BR | WH | SEE |
|
|
BR |
|
|
|
|
|
| NOTE 4 |
|
|
208/240 VOLTS
L1
1PLM
1 PLF |
| EM |
| L GN | |
1 |
| SEE NOTE 1 |
2 | 3 |
TR
L2
PLM 2
PLF 2
5
WH |
|
|
|
|
|
|
|
|
|
|
BL |
|
|
|
|
|
|
|
|
|
|
RD |
|
|
|
|
|
|
|
|
|
|
WH |
|
|
|
|
|
|
|
|
|
|
|
|
| PU |
|
|
|
|
|
|
|
CR |
|
|
|
| BK |
|
| RD |
| |
|
|
|
|
|
|
|
|
| ||
|
| 4 |
| SEE | BK |
|
|
| SEE |
|
|
| WH | NOTE 3 |
|
|
| NOTE 1 |
| ||
|
|
|
|
|
|
|
|
|
| |
RD | 2 | 5 |
| RD | C | 1 | 2 | 3 | 240 |
|
|
|
|
|
| ||||||
|
|
|
|
|
|
|
|
| TR |
|
GR | 1 | 3 |
|
|
| 5 | 24V | 4 |
|
|
|
|
| BL |
|
|
|
|
| BL |
|
|
|
|
|
|
| BL |
|
|
| |
|
| BL |
|
|
|
|
| FUSE | WH PU | |
|
|
|
| BL |
|
|
| |||
|
|
|
|
|
|
|
|
| ||
RD |
|
|
|
| RD |
|
|
| HOLDER | OR BR YL |
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
| 1 2 3 4 5 |
COPPER POWER SUPPLY |
|
|
|
|
|
|
|
|
| EM |
(USE RATING PLATE) |
|
|
|
|
|
|
|
|
| C L G N |
USE MIN. 75° C FIELD WIRE |
|
|
|
|
|
|
|
| RD BK BL |
|
IF REPLACEMENT OF THE ORIGINAL WIRES
SUPPLIED WITH THIS ASSEMBLY IS NECESSARY,
USE WIRE THAT CONFORMS TO THE NATIONAL
ELECTRIC CODE.
|
| 3 | 1 | 2 | 4 |
|
FUSE HOLDER | 4 24V | 5 |
|
| CR |
|
6 | 5 4 PLF |
|
| 1 |
| |
|
|
|
| 2 | EM | |
|
|
|
|
| 3 |
|
|
|
|
|
| 4 | C |
|
|
|
|
| 5 | |
|
|
|
|
|
| |
| R C G W1 W2 Y1 Y2 O DH 1 2 3 4 5 |
|
|
| ||
|
| COLOR CODE | WIRING CODE |
| ||||||||||||
BK | BLACK | GR | GREEN | FACTORY WIRING |
| |||||||||||
RD | RED | PU | PURPLE | HIGH VOLTAGE |
| |||||||||||
YL | YELLOW | BR | BROWN | LOW VOLTAGE |
|
|
|
|
|
| ||||||
|
|
| ||||||||||||||
BL | BLUE | WH | WHITE | FIELD WIRING |
| |||||||||||
|
|
|
|
| HIGH VOLTAGE |
| ||||||||||
COMPONENT CODE |
| LOW VOLTAGE |
|
|
|
|
| |||||||||
| TR |
|
|
|
| TRANSFORMER |
| |||||||||
EM |
| EVAPORATOR MOTOR |
|
|
|
|
| |||||||||
TB |
| TERMINAL BOARD | PLF |
|
|
|
| FEMALE PLUG CONNECTOR |
| |||||||
R |
| RELAY |
|
| PLM |
|
|
| MALE PLUG CONNECTOR |
| ||||||
CR |
| CONTROL RELAY | FL |
|
|
| FUSE LINK |
| ||||||||
EBTDR |
| ELECTRONIC BLOWER TIME | TL |
|
|
| THERMAL LIMIT |
| ||||||||
NOTES: | DELAY RELAY |
| HTR |
|
|
| HEAT ELEMENTS |
| ||||||||
|
|
|
|
| ||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||
1) RED WIRES TO BE ON TRANSFORMER TERMINAL "3" FOR 240 VOLTS AND ON TERMINAL |
| |||||||||||||||
"2" FOR 280 VOLTS. |
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||
2) SEE COMPLETE WIRING DIAGRAMS IN INSTALLATION INSTRUCTIONS FOR PROPER LOW |
| |||||||||||||||
VOLTAGE WIRING CONNECTIONS. |
|
|
|
|
|
|
|
|
|
|
|
| ||||
3) CONFIRM SPEED TAP SELECTION IS APPROPRIATE FOR APPLICATION. IF SPEED TAP |
| |||||||||||||||
NEEDS TO BE CHANGED, CONNECT PURPLE WIRE FROM TERMINAL 4 OF CR RELAY TO |
| |||||||||||||||
APPROPRIATE TAP AT TB |
|
|
|
|
|
|
|
|
|
|
|
| ||||
4) BROWN AND WHITE WIRES ARE USED FOR HEAT KITS ONLY. | ||||||||||||||||
Wiring is subject to change. Always refer to the wiring diagram on the unit for the most
13