HIGH VOLTAGE! DISCONNECT ALL POWER BEFORE SERVICING. WARNING MULTIPLE POWER SOURCES MAY BE PRESENT. FAILURE TO DO SO MAY CAUSE PROPERTY DAMAGE, PERSONAL INJURY OR DEATH.
ASPF Wiring Diagram
FL
TL
HTR1
| BK | BK | 1 |
|
| RD | 2 |
|
|
| |
BK | PU |
| 3 |
BL |
|
| |
|
|
| |
| M1 |
| 4 |
|
|
| |
| R |
| 5 |
| M2 |
| |
|
|
| |
| WH |
| 6 |
| BK |
| 7 |
| BK |
|
|
| RD |
| 8 |
FL |
| |
HTR1 | TL | |
| ||
FL |
| |
HTR2 | TL | |
BK | ||
|
|
| RD | BK | 1 |
|
|
| RD | 2 |
|
|
|
| |
RD |
| PU |
| 3 |
| BL |
|
| |
BK | M1 | M3 |
| 4 |
|
|
| ||
| R |
|
| 5 |
| M2 | M4 |
| |
|
|
| ||
|
| WH |
| 6 |
| BK |
|
|
|
| RD |
|
| 7 |
| BK |
|
|
|
|
| RD |
| 8 |
|
|
|
|
| FL |
|
|
|
|
|
|
| HTR1 |
| TL |
|
|
| FL |
|
|
|
| |
|
|
| TL |
|
| |
|
| HTR2 |
|
|
| |
|
|
| RD |
|
| |
|
| HTR3 |
| TL |
|
|
|
|
|
|
|
| |
|
|
|
|
| BK | 1 |
|
| RD | YL |
| 2 | |
|
| PU |
| |||
| YL |
|
| |||
| BK |
|
|
| ||
|
| BL |
| 3 | ||
|
|
|
|
| ||
|
| M1 | M3 | M1 | RD |
|
|
| BL | 4 | |||
RD |
|
|
|
| ||
| M2 | M4 | M2 |
|
| |
|
|
| R1 | R2 | BR | 5 |
BK | BK |
|
|
|
| |
| RD |
|
| WH | 6 | |
|
|
|
| |||
|
|
|
|
|
| 7 |
|
|
| YL |
|
| 8 |
|
|
|
|
|
| |
|
|
|
| BK |
|
|
|
|
| RD |
|
| 9 |
FL |
|
|
| TL |
|
| |
| HTR1 |
|
|
|
| ||
FL |
|
|
|
|
| ||
|
|
| TL |
|
| ||
| HTR2 |
|
|
|
| ||
|
|
|
|
|
| ||
| HTR3 |
|
| TL |
|
| |
|
|
|
|
|
| ||
| HTR4 |
|
| TL |
|
| |
|
|
| BL |
|
| ||
|
|
|
|
| BK | 1 | |
|
|
| PU |
|
| 2 | |
BL | BK RD |
|
|
| |||
| BL |
| 3 | ||||
YL | M1 | M3 | M5 | M7 | RD |
| |
BL | 4 | ||||||
|
|
|
| ||||
RD | M2 | M4 | M6 | M8 |
|
| |
BK | R1 | R2 | BR | 5 | |||
|
|
|
|
| |||
BK | RD |
|
|
| WH | 6 | |
|
|
|
| ||||
|
|
|
|
|
| 7 | |
|
| YL | BL |
|
| 8 | |
|
|
|
|
| |||
|
|
| BK |
|
|
| |
|
| RD |
|
|
| 9 |
9
9
L1 L2
L1 L2
L1 L2 L1 L2
L1 L2 L1 L2
ONE (1) ELEMENT ROWS
TWO (2) ELEMENT ROWS
THREE (3) ELEMENT ROWS
FOUR (4) ELEMENT ROWS
NOTE: WHEN INSTALLING HEATER KIT, ENSURE SPEED TAP DOES NOT EXCEED MINIMUM BLOWER SPEED (MBS) SPECIFIED FOR THE AIRHANDLER/HEATER
KIT COMBINATION ON THIS UNIT'S S&R PLATE. AFTER INSTALLING OPTIONAL HEAT KIT, MARK A "X" IN THE PROVIDED ABOVE. MARK ACCORDING TO NUMBER OF HEATER ELEMENT ROWS INST ALLED. NO MARK INDICATES NO HEAT KIT INSTALLED.
SEE NOTE 2 |
| GRD |
|
|
| EQUIPMENT GROUND |
| ||
|
|
|
|
| USE COPPER WIRE |
| |||
R C G W1 W2 Y1 Y2 O DH 1 2 3 4 5 | L1 | L2 |
|
|
|
|
|
|
|
PLM | 1 | 2 | 3 | 4 | 5 | 6 | 7 | 8 | 9 |
RD |
|
|
|
|
|
|
|
|
|
PLF | 1 | 2 | 3 | 4 | 5 | 6 | 7 | 8 | 9 |
GR | BK | RD |
| BL | BR | WH | SEE |
|
|
BR |
|
|
|
|
|
| NOTE 4 |
|
|
208/240 VOLTS
L1
1PLM
1 PLF |
| EM |
| L GN | |
1 |
| SEE NOTE 1 |
2 | 3 |
TR
L2
PLM 2
PLF 2
5
WH |
|
|
|
|
|
|
|
|
|
|
BL |
|
|
|
|
|
|
|
|
|
|
RD |
|
|
|
|
|
|
|
|
|
|
WH |
|
|
|
|
|
|
|
|
|
|
|
|
| PU |
|
|
|
|
|
|
|
CR |
|
|
|
| BK |
|
| RD |
| |
|
|
|
|
|
|
|
|
| ||
|
| 4 |
| SEE | BK |
|
|
| SEE |
|
|
| WH | NOTE 3 |
|
|
| NOTE 1 |
| ||
|
|
|
|
|
|
|
|
|
| |
RD | 2 | 5 |
| RD | C | 1 | 2 | 3 | 240 |
|
|
|
|
|
| ||||||
|
|
|
|
|
|
|
|
| TR |
|
GR | 1 | 3 |
|
|
| 5 | 24V | 4 |
|
|
|
|
| BL |
|
|
|
|
| BL |
|
|
|
|
|
|
| BL |
|
|
| |
|
| BL |
|
|
|
|
| FUSE | WH PU | |
|
|
|
| BL |
|
|
| |||
|
|
|
|
|
|
|
|
| ||
RD |
|
|
|
| RD |
|
|
| HOLDER | OR BR YL |
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
| 1 2 3 4 5 |
COPPER POWER SUPPLY |
|
|
|
|
|
|
|
|
| EM |
(USE RATING PLATE) |
|
|
|
|
|
|
|
|
| C L G N |
USE MIN. 75° C FIELD WIRE |
|
|
|
|
|
|
|
| RD BK BL |
|
IF REPLACEMENT OF THE ORIGINAL WIRES
SUPPLIED WITH THIS ASSEMBLY IS NECESSARY,
USE WIRE THAT CONFORMS TO THE NATIONAL
ELECTRIC CODE.
|
| 3 | 1 | 2 | 4 |
|
FUSE HOLDER | 4 24V | 5 |
|
| CR |
|
6 | 5 4 PLF |
|
| 1 |
| |
|
|
|
| 2 | EM | |
|
|
|
|
| 3 |
|
|
|
|
|
| 4 | C |
|
|
|
|
| 5 | |
|
|
|
|
|
| |
| R C G W1 W2 Y1 Y2 O DH 1 2 3 4 5 |
|
|
|
|
| COLOR CODE | WIRING CODE |
| ||||||||||||
BK | BLACK | GR | GREEN | FACTORY WIRING |
| |||||||||||
RD | RED | PU | PURPLE | HIGH VOLTAGE |
| |||||||||||
YL | YELLOW | BR | BROWN | LOW VOLTAGE |
|
|
|
|
|
| ||||||
|
|
| ||||||||||||||
BL | BLUE | WH | WHITE | FIELD WIRING |
| |||||||||||
|
|
|
|
| HIGH VOLTAGE |
| ||||||||||
COMPONENT CODE |
| LOW VOLTAGE |
|
|
|
|
| |||||||||
| TR |
|
|
|
| TRANSFORMER |
| |||||||||
EM |
| EVAPORATOR MOTOR |
|
|
|
|
| |||||||||
TB |
| TERMINAL BOARD | PLF |
|
|
|
| FEMALE PLUG CONNECTOR |
| |||||||
R |
| RELAY |
|
| PLM |
|
|
| MALE PLUG CONNECTOR |
| ||||||
CR |
| CONTROL RELAY | FL |
|
|
| FUSE LINK |
| ||||||||
EBTDR |
| ELECTRONIC BLOWER TIME | TL |
|
|
| THERMAL LIMIT |
| ||||||||
NOTES: | DELAY RELAY |
| HTR |
|
|
| HEAT ELEMENTS |
| ||||||||
|
|
|
|
| ||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||
1) RED WIRES TO BE ON TRANSFORMER TERMINAL "3" FOR 240 VOLTS AND ON TERMINAL |
| |||||||||||||||
"2" FOR 280 VOLTS. |
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||
2) SEE COMPLETE WIRING DIAGRAMS IN INSTALLATION INSTRUCTIONS FOR PROPER LOW |
| |||||||||||||||
VOLTAGE WIRING CONNECTIONS. |
|
|
|
|
|
|
|
|
|
|
|
| ||||
3) CONFIRM SPEED TAP SELECTION IS APPROPRIATE FOR APPLICATION. IF SPEED TAP |
| |||||||||||||||
NEEDS TO BE CHANGED, CONNECT PURPLE WIRE FROM TERMINAL 4 OF CR RELAY TO |
| |||||||||||||||
APPROPRIATE TAP AT TB |
|
|
|
|
|
|
|
|
|
|
|
| ||||
4) BROWN AND WHITE WIRES ARE USED FOR HEAT KITS ONLY. |
Wiring is subject to change. Always refer to the wiring diagram on the unit for the most
13