INSTALLER/CONFIGURATION MENU

To enter the menu: Press the Menu touch key. Press and hold for 5 seconds the Installer Config touch key. This displays screen reference #1 in the table below. Screen Reference numbers appear in top right corner of display. Pressto advance to the next menu item orto return to a previous menu item. Press or to change a menu item option. Shaded items are not available if selected for Non-Programmable. Write the options selected in the "Option Selected" column of the menu.

Installer Note: To default the programming, clock and Configuration Menu to the Factory Default Settings, press the , and SYSTEM keys simultaneously. The thermostat display will go blank for a few seconds, and then all segments will display momentarily. For heat pump systems, Configuration Menu items 1 and 3 must be set to match the heat pump system.

CONFIGURATION MENU

Screen

SS1

HP1

Press

Displayed

Press

or

 

 

 

Option

 

 

Reference

Factory

to select from

Comments

MS2

HP2

key

Selected

Number

 

 

 

(Default)

listed options

 

 

1

 

MS 2

HP 1, HP 2, SS 1

Selects Multi-Stage (MS2, No Heat Pump), Heat Pump 1

 

 

 

 

 

 

 

 

 

 

(HP1, 1 compressor), Heat Pump 2 (HP2, 2 compressor

 

 

 

 

 

 

 

 

 

 

or 2 speed compressor), or Single Stage.

 

 

 

 

 

 

 

 

 

 

 

 

2

 

(gas)

ele

 

 

 

GAS setting: furnace controls blower.

 

 

 

 

 

 

 

 

 

 

ELE setting: thermostat controls blower.

 

 

 

 

 

 

 

 

 

 

 

 

3

 

 

0b (0)

b

 

 

 

Selects Reversing Valve (This item is only to appear if HP1 or HP2

 

 

 

 

 

 

 

 

 

 

is selected above.)

 

 

 

 

 

 

 

 

 

 

 

4

 

Days, (7) P

5 or 0

Programs per week. (7 days, 5+1+1 days or non-programmable)

 

 

 

 

 

 

 

 

 

 

 

 

5

 

(4) PS

2

 

 

 

Programs per day.

 

 

 

 

 

 

 

 

 

 

4 = Morning, Day, Evening, Night

 

 

 

 

 

 

 

 

 

 

2 = Day, Night

 

 

 

 

 

 

 

 

 

 

Not available if 4 is 0

 

 

 

 

 

 

 

 

 

 

 

6

 

 

Cool-Off-

Cool-Off-Heat, Heat Off,

System switch configuration in non heat pump mode.

 

 

 

 

 

Heat-Auto

Heat, Cool-Off, Auto Off

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Cool-Off-Heat-

Cool-Off-Heat-Em,

System switch configuration, heat pump mode.

 

 

 

 

 

Em-Auto

Off-Em-Auto

 

 

 

 

 

 

 

 

 

 

 

 

 

7

 

(On) E

OFF

 

 

 

Selects Energy Management Recovery. Not available if 4 is 0

 

 

 

 

 

 

 

 

 

 

 

 

8

 

(FA) Heat, Cr

SL

 

 

 

Selects Adjustable Anticipation, cycle rate, Heat

 

 

 

 

 

 

 

 

 

 

 

 

9

 

(FA) Cool, Cr

SL

 

 

 

Selects Adjustable Anticipation, cycle rate, Cool

 

 

 

 

 

 

 

 

 

 

 

 

10

 

 

(FA) Cr/AU, Em

SL

 

 

 

Selects Adjustable Anticipation, cycle rate auxiliary, (This item is

 

 

 

 

 

 

 

 

 

 

only to appear if HP1 or HP2 is selected above).

 

 

 

 

 

 

 

 

 

 

 

 

11

 

(OFF) CL

On

 

 

 

Selects Compressor Lockout.

 

 

 

 

 

 

 

 

 

 

 

 

12

 

(On) dL

OFF

 

 

 

Selects Continuous Display backlight.

 

 

 

 

 

 

 

 

 

 

 

13

 

0

5, LO to 5, HI

Selects Adjustable Ambient Temperature Display [range -5 (LO) to

 

 

 

 

 

(Temperature)

 

 

 

 

+5 (HI)].

 

 

 

 

 

 

 

 

 

 

 

 

14

 

°F

°C

 

 

 

Selects °F/°C Display (temperature units in Fahrenheit or Celsius).

 

 

 

 

 

 

 

 

 

 

 

 

15

 

(On) b

OFF

 

 

 

Selects audible Beeper On/Off.

 

 

 

 

 

 

 

 

 

 

 

 

16

 

(On) dS

OFF

 

 

 

Selects Daylight Saving Time calculation.

 

 

 

 

 

 

 

 

 

 

 

 

17

 

(On) Heat, AS

OFF

 

 

 

Selects Automatic Schedule for comfort temperature Programming,

 

 

 

 

 

 

 

 

 

 

heat mode. Not available if 4 is 0

 

 

 

 

 

 

 

 

 

 

 

 

18

 

(On) Cool, AS

OFF

 

 

 

Selects Automatic Schedule for comfort temperature Programming,

 

 

 

 

 

 

 

 

 

 

cool mode. Not available if 4 is 0

 

 

 

 

 

 

 

 

 

 

 

 

19

 

(OFF) CS

On

 

 

 

Selects Cool Savings Feature On of Off.

 

 

 

 

 

 

 

 

 

 

 

20

 

CS Cool Savings

1-2-3-4-5-6

 

 

Selects amount of Cool Savings adjustment.

 

 

 

 

 

(3)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

21

 

(Off) CO

On

 

 

 

Select Compressor Optimization (not available on earlier models)

 

 

 

 

 

 

 

 

 

 

 

 

22

 

(OFF) CA

On

 

 

 

Selects Comfort Alert Feature On or Off. (not available on earlier

 

 

 

 

 

 

 

 

 

 

models)

 

 

 

 

 

 

 

 

 

 

 

23

 

(99) Heat, HL

62-98

 

 

TEMPERATURE LIMIT, HEAT (max. heat set point).

 

 

 

 

 

 

 

 

 

 

 

24

 

(45) Cool, LL

46-82

 

 

TEMPERATURE LIMIT, COOL (min. cool set point).

 

 

 

 

 

 

 

 

 

 

 

25

 

OFF,

L (total), P (partial),

Selects Keypad Lockout.

 

 

 

 

 

Temperature Limit

 

 

 

 

 

 

Keypad Lockout

 

 

 

 

 

 

(limited temperature range)

 

 

 

 

 

 

 

 

 

 

 

 

26

 

000

001-999

 

 

Selects Keypad Lockout Combination (active only if keypad Lockout

 

 

 

 

 

 

 

 

 

 

is selected).

 

 

 

 

 

 

 

 

 

 

 

 

27

 

(On) Heat, FS

OFF

 

 

 

Fast second stage of heat (not available if SS1 is selected above).

 

 

 

 

 

 

 

 

 

 

 

 

28

 

(On) Cool, FS

OFF

 

 

 

Fast second stage of cool (not available if SS1 or HP1 is selected

 

 

 

 

 

 

 

 

 

 

above).

 

 

 

 

 

 

 

 

 

 

 

 

29

 

Remote (OFF)

On

 

 

 

Remote temperature sensor, enable/disable.

 

 

 

 

 

 

 

 

 

 

 

30

 

Remote, In

Outdoor Remote

Remote temperature sensor (Indoor/Outdoor).

 

 

 

 

 

 

 

 

 

 

 

 

31

 

(On) LS

OFF

 

 

 

Local temp. Sensor enable/disable (only when Indoor Remote is

 

 

 

 

 

 

 

 

 

 

selected On).

 

 

 

 

 

 

 

 

 

 

 

 

32

 

 

(OFF) dF

On

 

 

 

Selects Dual Fuel feature On or OFF (this item appears if HP1 or

 

 

 

 

 

 

 

 

 

 

HP2 is selected above).

 

 

 

 

 

 

 

 

 

 

 

 

6

Page 6
Image 6
Emerson Process Management 1F95-1291 specifications INSTALLER/CONFIGURATION Menu, Key

1F95-1291 specifications

Emerson Process Management has established itself as a leader in providing innovative automation solutions to various industries. One of its notable offerings is the 1F95-1291, a highly advanced and reliable component specially designed for process control systems. This device is essential for optimizing operational efficiency and enhancing the performance of various industrial applications.

One of the main features of the 1F95-1291 is its robust design, which ensures reliability even in harsh industrial environments. The device is carefully constructed to withstand high levels of vibration, temperature fluctuations, and other challenging conditions. This durability reduces downtime and maintenance costs, allowing operators to focus on productivity.

Technologically, the 1F95-1291 integrates seamlessly with Emerson's extensive suite of control systems, providing compatibility and ease of integration. Its advanced communication capabilities allow it to interface with various field devices, enhancing the overall functionality of the automation system. The device supports various industrial communication protocols, ensuring versatile connectivity options that meet the diverse needs of modern industries.

The 1F95-1291 also features sophisticated algorithms that enable real-time data processing and analysis. This capability empowers operators to make informed decisions based on accurate and timely information. The built-in diagnostics function continuously monitors the system's health, providing alerts and insights that help in preemptive maintenance planning.

A standout characteristic of the 1F95-1291 is its user-friendly interface, designed to simplify operation and reduce training time. The intuitive display allows users to access critical information quickly, facilitating efficient management of operations. Additionally, firmware updates are easily manageable, ensuring that users can take advantage of the latest advancements without significant downtime.

In summary, Emerson Process Management's 1F95-1291 is a cutting-edge solution that exemplifies the company's commitment to innovation, reliability, and user-centric design. With its robust construction, advanced technologies, and user-friendly features, the 1F95-1291 is an essential asset for any organization seeking to enhance its process control capabilities and drive operational excellence. The device's adaptability to various industrial environments further underscores its value, making it a preferred choice among professionals in the field.