(I-0320--.doc/4) 4

I INTRODUCTION As many as eight flow-lines can be manifolded through one BETTIS Multiport Flow Selector. The multiport allows diversion of an individual flow-line to a test outlet for testing or sampling, while combining the flow of the other flow-lines into a separate group outlet. II MULTIPORT SPECIFICATIONS
RATING SIZE ANSI 300RF CONNECTION WEIGHT
TRIM MAXIMUM
WORKING
PRESSURE
PSIG
WORKING
TEMP
ΕC
NPS EIGHT
FLOWLINE
INLET
PORTS
ONE
TEST
OUTLET
PORT
ONE
GROUP
OUTLET
PORT
MULTIPORT
lbs.
STD. 740 38
HIGH TEMP 600 260 3x6 NPS 3 NPS 3 NPS 6 800
STD. 740 38
HIGH TEMP 600 260
4x8 NPS 4 NPS 4 NPS 8 1275
RATING SIZE ANSI 600RF CONNECTION WEIGHT
TRIM MAXIMUM
WORKING
PRESSURE
PSIG
WORKING
TEMP
ΕC
NPS EIGHT
FLOWLINE
INLET
PORTS
ONE
TEST
OUTLET
PORT
ONE
GROUP
OUTLET
PORT
MULTIPORT
lbs.
STD. 1000 200
HIGH TEMP 1440 260 2x4 NPS 2 NPS 2 NPS 4 180
STD. 1440 38
HIGH TEMP 1200 260 3x6 NPS 3 NPS 3 NPS 6 860
STD. 1480 38
HIGH TEMP 600 260
4x8 NPS 4 NPS 4 NPS 8 1375
RATING SIZE ANSI 900RF CONNECTION WEIGHT
TRIM MAXIMUM
WORKING
PRESSURE
PSIG
WORKING
TEMP
ΕC
NPS EIGHT
FLOWLINE
INLET
PORTS
ONE
TEST
OUTLET
PORT
ONE
GROUP
OUTLET
PORT
MULTIPORT
lbs.
STD. 2220 38
HIGH TEMP 1795 260 3x6 NPS 3 NPS 3 NPS 6 1800
STD. 2220 38
HIGH TEMP 1795 260
4x10 NPS 4 NPS 4 NPS 10 3200
RATING SIZE ANSI 1500RF CONNECTION WEIGHT
TRIM MAXIMUM
WORKING
PRESSURE
PSIG
WORKING
TEMP
ΕC
NPS EIGHT
FLOWLINE
INLET
PORTS
ONE
TEST
OUTLET
PORT
ONE
GROUP
OUTLET
PORT
MULTIPORT
lbs.
STD. 3705 38
HIGH TEMP 2995 260 3x6 NPS 3 NPS 3 NPS 6 1875