MULTIPORT SIZE

 

NPS 2"

 

 

NPS 3"

 

 

NPS 3"

 

NPS 4"

 

NPS 4"

 

 

AND RATING

 

 

ANSI 600

 

ANSI 600

 

ANSI 900/1500

 

ANSI 600

 

ANSI 900

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

TEST OUTLETCV

 

 

67

 

 

151

 

 

100

 

270

 

218

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

GROUP OUTLET CV

 

262

 

 

594

 

 

429

 

1040

 

830

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

SHELL

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

3330

 

 

HYDROSTATIC

 

 

2200-2220

 

2160

 

 

5560

 

2220

 

 

 

TEST PRESSURE

 

(13780-15300)

 

(14900)

 

 

(38310)

 

(15300)

 

(22950)

 

 

PSIG (KPa)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

MAXIMUM DYNAMIC DIFFERENTIAL

 

STATIC STATIONARY DIFFERENTIAL

 

 

 

 

 

 

 

 

 

 

 

 

 

PSID @ 40ΕC

 

 

 

 

PSID @ 40ΕC

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

MULITPORT SIZE

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

AND RATING

 

TEST-GROUP

 

GROUP-TEST

 

TEST-GROUP

 

GROUP-TEST

 

 

 

 

 

 

 

 

NPS 2X4

 

 

600

 

 

550

 

1200

 

900

 

 

 

 

 

 

 

 

ANSI 600

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

NPS 3X6

 

 

500

 

 

450

 

1000

 

700

 

 

 

 

 

 

 

 

 

ANSI 60

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

NPS 3X6

 

 

500

 

 

450

 

1000

 

700

 

 

 

 

 

 

 

 

ANSI 900/1500

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

NPS 4X8

 

 

400

 

 

350

 

800

 

600

 

 

 

 

 

 

 

 

ANSI 600

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

NPS 4X10

 

 

400

 

 

350

 

800

 

600

 

 

 

 

 

 

 

 

ANSI 900

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Note: In Emergency situations only, the Multiport Flow Selector seal can maintain STATIC STATIONARY DIFFERENTIAL pressure rating per specifications above. However, do not operate the motor operator at greater than the MAXIMUM DYNAMIC DIFFERENTIAL pressure rating because damage may occur to the motor operator.

 

IIB

ACTUATOR SPECIFICATIONS:

 

 

 

 

 

 

 

 

 

 

 

 

 

MULTIPORT SIZE

NPS 2"

NPS 3"

NPS 3"

NPS 4"

NPS 4"

 

 

AND RATING

ANSI 600

ANSI 600

ANSI 900/1500

ANSI 600

ANSI 900

 

 

 

 

 

 

 

 

 

 

PLUG POSITION

+/- 2Ε

+/- 2Ε

+/- 2Ε

+/- 2Ε

+/- 2Ε

 

 

TOLERANCE

 

 

 

 

 

 

 

BREAKAWAY

100-125 FT-LBS

100-170 FT-LBS

150-200 FT-LBS

150-210 FT-LBS

150-210 FT-LBS

 

 

TORQUE @ MAX

 

 

 

 

 

 

 

DIFFERENTIAL

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

ACTUATOR SPEED

1.4 RPM

1.4 RPM

1.4 RPM

1.4 RPM

1.4 RPM

 

 

 

 

 

 

 

 

 

 

ACTUATOR

50 LBS

130 LBS

130 LBS

130 LBS

150 LBS

 

 

 

WEIGHT

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

PLUG POSITION

+/- 1Ε

+/- 1Ε

+/- 1Ε

+/- 1Ε

+/- 1Ε

 

 

ACCURACY

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(I-0320--.doc/5)

5

Page 5
Image 5
Emerson Process Management I-0320 service manual IIB Actuator Specifications