| MULTIPORT SIZE |
| NPS 2" |
|
| NPS 3" |
|
| NPS 3" |
| NPS 4" |
| NPS 4" |
| |||||||||
| AND RATING |
|
| ANSI 600 |
| ANSI 600 |
| ANSI 900/1500 |
| ANSI 600 |
| ANSI 900 |
| ||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| TEST OUTLETCV |
|
| 67 |
|
| 151 |
|
| 100 |
| 270 |
| 218 |
| ||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
| GROUP OUTLET CV |
| 262 |
|
| 594 |
|
| 429 |
| 1040 |
| 830 |
| |||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| SHELL |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| 3330 |
| ||||
| HYDROSTATIC |
|
|
| 2160 |
|
| 5560 |
| 2220 |
|
| |||||||||||
| TEST PRESSURE |
|
| (14900) |
|
| (38310) |
| (15300) |
| (22950) |
| |||||||||||
| PSIG (KPa) |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |||||||
|
|
|
|
|
|
|
| MAXIMUM DYNAMIC DIFFERENTIAL |
| STATIC STATIONARY DIFFERENTIAL |
|
|
|
| |||||||||
|
|
|
|
|
|
|
|
| PSID @ 40ΕC |
|
|
|
| PSID @ 40ΕC |
|
|
|
| |||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |||
|
|
| MULITPORT SIZE |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |||
|
|
| AND RATING |
|
|
|
|
|
|
|
| ||||||||||||
|
|
|
| NPS 2X4 |
|
| 600 |
|
| 550 |
| 1200 |
| 900 |
|
|
|
|
| ||||
|
|
| ANSI 600 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||
|
|
|
| NPS 3X6 |
|
| 500 |
|
| 450 |
| 1000 |
| 700 |
|
|
|
|
| ||||
|
|
|
| ANSI 60 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
|
|
|
| NPS 3X6 |
|
| 500 |
|
| 450 |
| 1000 |
| 700 |
|
|
|
|
| ||||
|
|
| ANSI 900/1500 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |||
|
|
|
| NPS 4X8 |
|
| 400 |
|
| 350 |
| 800 |
| 600 |
|
|
|
|
| ||||
|
|
| ANSI 600 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||
|
|
| NPS 4X10 |
|
| 400 |
|
| 350 |
| 800 |
| 600 |
|
|
|
|
| |||||
|
|
| ANSI 900 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Note: In Emergency situations only, the Multiport Flow Selector seal can maintain STATIC STATIONARY DIFFERENTIAL pressure rating per specifications above. However, do not operate the motor operator at greater than the MAXIMUM DYNAMIC DIFFERENTIAL pressure rating because damage may occur to the motor operator.
| IIB | ACTUATOR SPECIFICATIONS: |
|
|
|
| ||
|
|
|
|
|
|
|
| |
| MULTIPORT SIZE | NPS 2" | NPS 3" | NPS 3" | NPS 4" | NPS 4" |
| |
| AND RATING | ANSI 600 | ANSI 600 | ANSI 900/1500 | ANSI 600 | ANSI 900 |
| |
|
|
|
|
|
|
|
| |
| PLUG POSITION | +/- 2Ε | +/- 2Ε | +/- 2Ε | +/- 2Ε | +/- 2Ε |
| |
| TOLERANCE |
|
|
|
|
|
| |
| BREAKAWAY |
| ||||||
| TORQUE @ MAX |
|
|
|
|
|
| |
| DIFFERENTIAL |
|
|
|
|
|
| |
|
|
|
|
|
|
|
| |
| ACTUATOR SPEED | 1.4 RPM | 1.4 RPM | 1.4 RPM | 1.4 RPM | 1.4 RPM |
| |
|
|
|
|
|
|
|
| |
| ACTUATOR | 50 LBS | 130 LBS | 130 LBS | 130 LBS | 150 LBS |
| |
|
| WEIGHT |
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
| PLUG POSITION | +/- 1Ε | +/- 1Ε | +/- 1Ε | +/- 1Ε | +/- 1Ε |
| |
| ACCURACY |
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
5