(I-0320--.doc/5) 5

MULTIPORT SIZE
AND RATING
NPS 2"
ANSI 600 NPS 3"
ANSI 600 NPS 3"
ANSI 900/1500 NPS 4"
ANSI 600 NPS 4"
ANSI 900
TEST OUTLETCV 67 151 100 270 218
GROUP OUTLET CV 262 594 429 1040 830
SHELL
HYDROSTATIC
TEST PRESSURE
PSIG (KPa)
2200-2220
(13780-15300)
2160
(14900)
5560
(38310)
2220
(15300)
3330
(22950)
MAXIMUM DYNAMIC DIFFERENTIAL
PSID @ 40ΕC STATIC STATIONARY DIFFERENTIAL
PSID @ 40ΕC
MULITPORT SIZE
AND RATING
TEST-GROUP
GROUP-TEST
TEST-GROUP
GROUP-TEST
NPS 2X4
ANSI 600 600 550 1200 900
NPS 3X6
ANSI 60 500 450 1000 700
NPS 3X6
ANSI 900/1500 500 450 1000 700
NPS 4X8
ANSI 600 400 350 800 600
NPS 4X10
ANSI 900 400 350 800 600

Note: In Emergency situations only, the Multiport Flow Selector seal can maintain STATIC STATIONARY DIFFERENTIAL pressure rating per specifications above. However, do not operate the motor operator at greater than the MAXIMUM DYNAMIC DIFFERENTIAL pressure rating because damage may occur to the motor operator. IIB ACTUATOR SPECIFICATIONS:

MULTIPORT SIZE
AND RATING
NPS 2"
ANSI 600 NPS 3"
ANSI 600 NPS 3"
ANSI 900/1500 NPS 4"
ANSI 600 NPS 4"
ANSI 900
PLUG POSITION
TOLERANCE +/- 2Ε +/- 2Ε +/- 2Ε +/- 2Ε +/- 2Ε
BREAKAWAY
TORQUE @ MAX
DIFFERENTIAL
100-125 FT-LBS 100-170 FT-LBS 150-200 FT-LBS 150-210 FT-LBS 150-210 FT-LBS
ACTUATOR SPEED 1.4 RPM 1.4 RPM 1.4 RPM 1.4 RPM 1.4 RPM
ACTUATOR
WEIGHT 50 LBS 130 LBS 130 LBS 130 LBS 150 LBS
PLUG POSITION
ACCURACY +/- 1Ε +/- 1Ε
+/- 1Ε
+/- 1Ε
+/- 1Ε