Tripp Lite INT 300 owner manual OmniPro INT, New Specifications, ESPAÑOL p FRANÇAIS p DEUTSCH p

Models: INT 300

1 4
Download 4 pages 18.1 Kb
Page 1
Image 1
Owner’s Manual Addendum to #93-1208

1111 W. 35th Street

Chicago, IL 60609 USA

Customer Support: (773) 869-1234

www.tripplite.com

Owner’s Manual Addendum to #93-1208

OmniProINT 300

Line Interactive UPS System

220/240V, 50/60Hz

ESPAÑOL: p. 2

FRANÇAIS : p. 3

DEUTSCH: p. 4

New Specifications

 

OmniPro INT 300

Output Capacity (VA/Watts):

300/175

 

Input Frequency

50/60 Hz

Battery Runtime (Half Load/

 

 

Full Load) Minutes:

17/5

 

Typical Runtime (Desktop

 

 

PC/15 in. monitor) Minutes:

15

 

Battery Recharge Time:

2-4 hours

Dimensions (H x W x D):

21 x 10.8 x 14.6 cm

Weight

5 kg

Approvals:

UL, CE

The new OmniPro INT 300 shares all of the functions of the OmniSmart INT 280 in the accompanying manual, with the following exceptions:

The OmniPro INT 300 does not feature a DB9 serial port and does not include PowerAlert Software or cabling.

The OmniPro INT 300 has two diagnostic LEDs that indicate on-line and on- battery status.

The OmniPro INT 300 has no Alarm Mute/Test Switch.

The OmniPro INT 300 features two IEC-320 AC output receptacles.

The OmniPro INT 300 features a battery replacement door on the rear panel. Under normal conditions, the original battery in the UPS system will last between 3 and 6 years. Qualified service personnel should read and observe all precautions listed below before attempting replacement.

Battery Replacement WARNINGS: Battery replacement should be performed by qualified service personnel only. Disconnect UPS from wall receptacle before performing battery replacement. Keep all other people away from the area when performing battery replacement. The batteries contain lead and acid. Do not dispose of the batteries in a fire. Do not open the batteries. Do not short or bridge the battery terminals with any object. Do not touch the loose battery terminal wires together or to any metal part of the UPS cabinet. Except for the replaceable battery, the UPS contains no user replaceable parts. A battery can present a risk of electrical shock or burn from high short-circuit current. Observe the following precautions while replacing batteries: 1) Remove watches, rings and all other metal objects; 2) Use tools with insulated handles. After removing UPS batteries, proper disposal is required. The batteries are recyclable. Refer to your local codes for complete recycling information. When replacing batteries, use the same number and type batteries originally installed in your UPS. Contact OmniPro™ INT 300Line Interactive UPS SystemESPAÑOL: p. 2New SpecificationsManual backgroundManual background customer support at (773) 869-1234 for further information on battery replacement.

Copyright © 2000 Manual backgroundManual backgroundManual backgroundManual background. All rights reserved. OmniSmartand OmniProare trademarks of Manual backgroundManual backgroundManual backgroundManual background.