Instruction Manual
Model NGA2000 NDIR
From MAIN MENU
⇓
Technical configuration menu
System set up...
Service menus...
Diagnostic menus...
Other module diagnostic menus...
Listing of all modules...
For Diagnostic menus, Other module diagnostic menus, and Listing of all modules, see Figure
System Set Up
Main display configuration...
Front panel control... |
|
Date and time... |
|
Module binding... |
|
System Reset... |
|
Security codes... |
|
System tag: | Rosemount |
Main display configuration, Front panel control, and Date and time displays can be found in the Platform manual.
Module Binding
Analyzer module selected:
Proposed bind: View bindings...
Bind selections! Unbind everything!
System Reset
Are you sure?
Record security codes
Basic level security: | Enabled |
Expert level security: | Enabled |
Technical level security: | Enabled |
Record basic level security code...
Record expert level security code...
Record technical level security code...
Select IO modules
Select the modules you wish to bind to the current analyzer.
Module Tag
Module Tag
Module Tag
Module Tag
Module Tag
Module Tag
Module Tag
Module Tag
Modules Bound
Analyzer module selected: | |
Auxiliary module: | Auto 1023 |
Auxiliary module: | Acal 2322 |
Auxiliary module: | HART 1092 |
Auxiliary module: | None |
Auxiliary module | None |
Auxiliary module: | None |
Proposed new bind: |
|
#7
Record basic level security codes
(expert, technical)
Press the softkeys in any order to define the code. The actual code is represented by the order in which they are pressed, and shown numerically below. Press the left arrow key when you are done.
Actual code number: | 54321 |
Manufacturing data
Control module data...
Analyzer module data...
Module Tag
Module Tag
Module Tag
Module Tag
Module Tag
Module Tag
Module Tag
Module Tag
Service Menus
Manufacturing data...
Service history...
In maintenance since:N/A
Record security codes...
Service History
Control module data...
Analyzer module data...
Module Tag
Module Tag
Module Tag
Module Tag
Module Tag
Module Tag
Module Tag
Module Tag
Record security codes
Basic level security: | Enabled |
Expert level security: | Enabled |
Technical level security: | Enabled |
Record basic level security code...
Record expert level security code...
Record technical level security code...
See #7 above
Control Unit Manufacturing Data
Control unit serial number: | 800002356 |
Manufacturing date code: | |
Hardware revision number: | 1.00 |
Software revision number: | 1.09 |
Revision notes... |
|
User tag number: | PV1c |
Analyzer Manufacturing Data
Analyzer module s/n: | 900189342 |
Manufacturing data code: | |
Bench configuration code: | 17 |
Hardware revision number: | 1.13 |
Software revision number: | 1.03 |
Minimum range: | 10 ppm |
Maximum range: | 5000 ppm |
Measured gas: | CO2 |
User tag number: |
STORERESET
Store historical data
Are you sure?
STORE will copy current diagnostic data into the historical ("was") variables, overwriting what is currently there.
Reset
Are you sure?
RESET will erase ALL configuration and manufacturing data, including serial numbers.
Control Module Service History
Manufacturing date: | |
In service date: | |
Last service date: | |
List notes... |
|
Add service date! |
|
Analyzer module Service History
Manufacturing date: | |
In service date: | |
Last zero calibration date: | |
Last span calibration date: | |
Last service date: | |
List notes... |
|
Add service date! |
|
I/O module |
|
This function not applicable. |
|
Slot position: | 1 |
Figure
Startup and Operation | Rosemount Analytical Inc. A Division of Emerson Process Management |