FOR YOUR SAFETY READ BEFORE LIGHTING

WARNING: If you do not follow these instructions exactly, a fire or explosion may result

causing property damage, personal injury or loss of life.

A.This appliance has a pilot which must be lighted by hand. When lighting the pilot, follow these instructions exactly.

B.BEFORE LIGHTING smell all around the appliance area for gas. Be sure to smell next to the floor because some gas is heavier than air and will settle on the floor.

WHAT TO DO IF YOU SMELL GAS

Do not try to light any appliance.

Do not touch any electrical switch;

do not use any phone in your building.

Immediately call your gas supplier from a neigh- bor's phone. Follow the gas supplier's instructions.

If you cannot reach your gas supplier, call the fire department.

C.Use only your hand to push in or turn the gas control handle. Never use tools. If the handle will not push in or turn by hand, don't try to repair it; call a qualified service technician. Force or attempted repair may result in a fire or explosion.

D.Do not use this appliance if any part has been under water. Immediately call a qualified service techni- cian to inspect the appliance and to replace any part of the control system and any gas control which has been under water.

LIGHTING INSTRUCTIONS

1.STOP! Read the safety information above.

2.Set the thermostat to lowest setting.

3.Remove floor register.

NOTE: The gas control handle is attached to the gas control knob.

4.Push in gas control handle slightly and turn clock-

wise to "OFF."

NOTE: Handle cannot be turned from "PILOT" to "OFF" unless handle is pushed in slightly. Do not force.

5.Remove the pilot access cover located on the combustion chamber.

6.Wait ten (10) minutes to clear out any gas. Then smell for gas, including near the floor. If you smell gas, STOP! Follow "B" in the safety information above. If you don't smell gas, go to the next step.

7.Find pilot - the pilot is adjacent to the center portion of the main burner in the area directly below

3588 5088

the pilot access open-7088 ing.

8.Turn gas control handle counterclockwise to "PILOT."

9.Push and hold control handle in and repeatedly push the ignitor button until pilot is lit (or use match and lighter rod to light.) Continue to hold the control handle in for about one (1) minute after the pilot is lit. Release handle and it will pop back up. Pilot should remain lit. If it goes out, repeat steps 4 through 9.

If handle does not pop up when released, stop and immediately call a qualified service tech- nician or gas supplier.

If the pilot will not stay lit after several tries, turn the gas control handle to "OFF" and call your service technician or gas supplier.

10.Replace pilot access cover.

11.Turn gas control handle counterclockwise to "ON."

12.Replace floor register.

13.Set thermostat to desired setting.

TO TURN OFF GAS TO APPLIANCE

1.

Set the thermostat to lowest setting.

3.

Push in gas control handle slightly and turn

2.

Remove floor register.

 

clockwise

to "OFF." Do not force.

 

 

 

 

 

4.

Replace floor register.

R-1842

Page 7

Page 7
Image 7
Empire Comfort Systems 7088-3 For Your Safety Read Before Lighting, Lighting Instructions, To Turn OFF GAS to Appliance

5088-3, 7088-3, 3588-3 specifications

Empire Comfort Systems offers a reliable range of heating solutions, with the models 5088-3, 7088-3, and 3588-3 standing out for their exceptional performance and innovative features. These gas-fired wall heaters are designed to provide efficient heat while maintaining user-friendly operations and stylish aesthetics.

One of the key features of the Empire Comfort Systems 5088-3 is its compact design, allowing it to fit snugly into smaller spaces without sacrificing heating capability. It boasts a powerful capacity to heat areas swiftly and effectively, making it ideal for both residential and commercial applications. The heater utilizes natural gas or propane, ensuring flexibility in fuel preference and availability.

The 7088-3 model expands upon this with additional features, including a built-in thermostat that allows for precise temperature control. This thermostat enables users to set their desired heat levels, ensuring optimal comfort without unnecessary energy expenditure. Another significant characteristic of the 7088-3 is its safety features, which include an automatic shut-off system that kicks in during abnormal conditions, providing peace of mind for users.

The 3588-3 model emphasizes efficiency, featuring advanced technologies that maximize heat output while minimizing fuel consumption. With a sleek design available in various finishes, it can seamlessly integrate into any home or office decor. The 3588-3 also prioritizes safety, equipped with a reliable ignition system that enhances operational security.

All three models feature Empire's proprietary Heating Technology, designed to distribute warmth evenly across the space, eliminating cold spots and ensuring consistent comfort. Additionally, they operate quietly, making them perfect for bedrooms, living rooms, or office environments where noise levels are a concern.

Whether you are looking for efficient heating solutions for your home or business, the Empire Comfort Systems models 5088-3, 7088-3, and 3588-3 each offer unique advantages. Their combination of advanced technology, safety features, and stylish designs positions them as leading choices in the market for reliable and effective heating solutions. With Empire Comfort Systems, achieving warmth and comfort becomes an effortless experience.