Page 29R-5086
OPTIONAL BLOWER CIB-2Direct Vent Fireplace CIDV-30
Installing Optional CIB-2 Blower
1. Loosen, but do not remove, (4) hex-head screws located on the
exterior, bottom of the appliance.
2. Position the blower assembly at the rear of the appliance. The
blower assembly has (4) keyholes for attachment to the exterior,
bottom of the appliance.
3. Place the large diameter holes in the keyholes over and behind the
(4) hex-head screws that were loosened in Step 1. Push inward on
the blower assembly to lock the keyholes into position behind the
screws. Tighten (4) hex-head screws to secure blower assembly to
exterior, bottom of the appliance.
4. Remove wire channel from channel divider by removing (2) 10 x
1/2" screws. Note: If optional blower is being installed during
initial installation of appliance, the wire channel will not be
attached to rear cover. (Refer to Installation of Wire Channel
Assembly, Page 9)
5. Remove channel divider from rear cover by removing (2) 10 x
1/2" screws.
6. Attach fan control to OFFSET, fan control bracket (Part 9B, Page
28) with (2) 6 x 1/4" screws provided in hardware package.
7. Attach fan control with bracket onto air drop with (2) 10 x 1/2"
screws provided in hardware package.
8. Route fan control wires through 1/2" extruded hole on channel
divider. Attach fan control wires to fan control.
9. Attach channel divider with (2) 10 x 1/2" screws from Step 5.
10. Route wires from fan control and ON/OFF/REMOTE switch
within wire channel.
11. Attach wire channel to channel divider with (2) 10 x 1/2" screws
from Step 4. (Refer to Installation of Wire Channel Assembly,
Page 9)
12. Insert AUTO/OFF/ON switch into rectangular notch on valve
bracket. Be sure to insert AUTO/OFF/ON switch with letters
(words) upright. (See wiring diagram)
13. Attach 1/4" push-on terminal from blue wire on the fan control
to the AUTO (top) tab on the switch.
14. Attach 1/4" push-on terminal from black wire to the OFF
(middle) tab on the switch.
15. Attach 1/4" push-on terminal from white wire on the fan
control to the ON (bottom) tab on the switch.
16. Installation of optional CIB-2 blower is completed.
Fan Control
The fan control is a non-adjustable automatic type The fan control will
require between 5 and 10 minutes of main burner operation before
the fan control "closes" and activates the blower. The blower will
continue to run between 5 and 10 minutes after the main burner shuts
off, before the fan control "opens" and deactivates the blower.
Wiring
The appliance, when installed, must be electrically grounded in
accordance with local codes or, in the absence of local codes, with
the National Electrical Code, ANSI/NFPA 70 or Canadian Electrical
Code, CSA C22.1, if an external electrical source is utilized. This
appliance is equipped with a three-prong [grounding] plug for
your protection against shock hazard and should be plugged
directly into a properly grounded three-prong receptacle. Do
not cut or remove the grounding prong from this plug. For an
ungrounded receptacle, an adapter, which has two prongs and a wire
for grounding, can be purchased, plugged into the ungrounded
receptacle and its wire connected to the receptacle mounting screws.
With this wire completing the ground, the appliance cord plug can
be plugged into the adapter and be electrically grounded.
CAUTION: Label all wires prior to disconnection when servicing
controls. Wiring errors can cause improper and dangerous operation.
Verify proper operation after servicing.
WARNING:
Unplugging of blower accessory will not stop the heater from
cycling. To shut heater off: Turn temperature dial or
thermostat to lowest setting. Turn knob on gas control to
"OFF", depressing slightly. Do not force.