LIGHTING INSTRUCTIONS

FOR YOUR SAFETY READ BEFORE LIGHTING

WARNING: If you do not follow these instructions exactly, a fire or explosion may result

causing property damage, personal injury or loss of life.

A.

This appliance has a pilot which must be lighted by

• If you cannot reach your gas supplier, call the fire

 

hand. When lighting the pilot, follow these instructions

department.

 

exactly.

C. Use only your hand to push in or turn the gas control

B.

BEFORE LIGHTING smell all around the appliance area

knob. Never use tools. If the knob will not push in or turn

 

for gas. Be sure to smell next to the floor because some

by hand, don't try to repair it; call a qualified service

 

gas is heavier than air and will settle on the floor.

technician. Force or attempted repair may result in a fire

 

WHAT TO DO IF YOU SMELL GAS

or explosion.

 

• Do not try to light any appliance.

D. Do not use this appliance if any part has been under water.

 

• Do not touch any electrical switch;

Immediately call a qualified service technician to inspect

 

do not use any phone in your building.

the appliance and to replace any part of the control system

 

• Immediatelycallyourgassupplierfromaneighbor's

and any gas control which has been under water.

 

phone. Follow the gas supplier's instructions.

 

LIGHTING INSTRUCTIONS

1.STOP! Read the safety information above.

2.Set the thermostat to lowest setting.

3.Turn off all electric power to the appliance.

4.Remove control access panel (lower front panel).

5.Turn gas control knob clockwise to "OFF."

6.Wait ten (10) minutes to clear out any gas. Then smell for gas, including near the floor. If you smell gas, STOP! Follow "B" in the safety information above. If you don't smell gas, go to the next step.

7.Remove the pilot access cover located on the combustion chamber.

8.Find pilot - follow metal tube from gas control. The pilot is located between the twoburnertubesbehindthe pilot access cover.

9.Turn gas control knob counterclockwise to "PI- LOT."

10.Push and hold red reset button down completely and repeatedly push the ignitor button until the pilot burner is lit. Pilot may also be lit with a match. Continue to hold the red reset button down for about one (1) minute after the pilot is lit. Release button and it will pop back up. Pilot should remain lit. If it goes out, repeat steps 5 through 10.

If button does not pop up when released, stop and immediately call a qualified service technician or gas supplier.

If the pilot will not stay lit after several tries, turn the gas control knob to "OFF" and call your service technician or gas supplier.

11.Replace pilot access cover.

12.Turn gas control knob counterclockwise to "ON."

13.Replace control access panel (lower front panel).

14.Turn on all electric power to the appliance.

15.Set thermostat to desired setting.

TO TURN OFF GAS TO APPLIANCE

1.Set the thermostat to lowest setting.

2.Turn off all electric power to appliance if service is to be performed .

3.Remove control access panel (lower front panel).

4.Push in gas control knob slightly and turn clockwise to "OFF." Do not force.

5.Replace control access panel (lower front panel).

Page 12

13118-7-0408

Page 12
Image 12