PILOT FLAME CHARACTERISTICS

The correct pilot flame (Figure 12) will be blue, extending past

PROPER FLAME ADJUSTMENT

the thermocouple. The flame will surround the thermocouple just

 

below the tip.

 

Natural gas pilots require adjusting when the inlet gas pressure is

 

above 5" w.c. Remove the pilot cover screw on the control valve

 

(Figure 3, page 8), and turn the adjustment screw clockwise to

 

reduce flame. Replace pilot cover screw to eliminate gas leaking

 

at that control valve opening.

 

LP gas (propane) will not require adjustment.

 

After use, cleaning may be required for the proper flame.

 

Figure 12

MAIN BURNER FLAME CHARACTERISTICS

The correct flame will be a short blue inner flame with a much larger light blue outer flame. The main burner (Figure 13) shows the approximate height of each part of the flame for each gas. The burner does not have a primary air adjustment. The flame will be correct if the factory-set pressure and orifice opening are used.After the furnace has been operating, the burner ports may be blocked by foreign matter carried in by combustion air. Therefore, cleaning of the burner may be needed for proper flame.

To clean burner port disconnect the gas supply to the valve, and

 

remove the eight screws fastening the burner door. After remov-

 

ing the burner door from the combustion chamber, remove rear

Figure 13

burner, pilot burner and front burner. With front and rear burners

 

removed from furnace, force water into the ribbon ports and dry

 

with air pressure.

 

13118-7-0408

Page 13