SEQUENCE OF OPERATION

START

System Check

Trial for

Ignition

Main Burner

Operation

END

Apply 24 VAC

To Appliance

Thermostat

Calls for Heat

Flame Signal

YES

Detected

 

 

 

NO

 

 

NO

Internal Check

 

OK

 

 

 

YES

 

Pilot Valve Opens

Ignitor Powered

Pilot Light and Flame is

NO

Sensed During Trial For

 

Ignition (1)

 

 

 

YES

Ignitor OFF

Main Valve Opens

Flame Signal

YES

Lost?

 

NO

Thermostat Call for Heat

Ends

Main Pilot Valves

Close

5 Minute Retry Delay

Pilot Valve Ignition OFF

Wait for Flame Signal to Disappear

Pilot Valve Closes

Ignition OFF

3 Second Flame Recycle

Delay

Main Pilot

Valves Close

Flame Lost More

NO

Than 5 Times in

 

One Call for Heat

 

YES

 

(1)Ignitor will turn OFF about 30 seconds into the trial for ignition if the pilot flame has not lit. It will turn back ON for the final 30 seconds of the 90 second trial for ignition. The pilot valve will be energized during the entire trial for ignition. This is normal operation for this gas ignition system.