Figure 5
Use U.L. listed gas vent equipment when installing the
and attach side wall plate to furnace side of wall with (2) #10 x 1 1/2" (38mm) provided screws.
5.Attach outer boot to the cabinet side with (4) #8 x 1/4" (6mm) provided screws.
6.Position and attach inner boot to inner shield with (4) #8 x 1/4" (6mm) provided screws.
7.Place the register over the 6 3/4" (171mm) square opening with the louvers positioned for the desired discharge direction and mark the mounting holes using the register as a template.
8.Drill (2) 1/8" (3mm) diameter holes in the wall and attach the register with (2) #10 x 1 1/2" (38mm) provided screws.
9.Installation of
4" MINIMUM TO COMBUSTIBLE� | 4" MINIMUM TO COMBUSTIBLE� |
WALL OR SURFACE | WALL OR SURFACE |
| WALL |
| 18" MIN. CLEARANCE TO |
| WALL OR COMBUSTIBLE |
| SURFACE USING MODEL |
|
CLEARANCE FOR SIDE OUTLET KITS AND REAR REGISTER�
KIT TO ADJACENT WALL
combustible construction, use
TYPE
VENT PIPE
UNIT CANNOT BE RECESSED� WHEN SIDE REGISTERS ARE� USED.
Be sure baseplate is attached to top of furnace before inserting unit into recessed wall installation.
Installing Optional Side Outlets
Side outlet register,
1. | Turn "OFF" all electric power to the furnace. |
2. | Remove the front panel from the furnace. |
3. | Remove the (2) #8 x 3/8" (9mm) screws that attach the inner shield |
5 1/2"
5 1/2"
12"
6 1/4" |
10 1/4" |
12" |
cover plate to the inner shield. |
4. Scribe a line between the four dimples on the outer casing side to form |
WHEN SIDE REGISTERS ARE�
NOT USED UNIT MAY BE RECESSED� UP TO 9 1/2"
REAR REGISTER OPENING� IN OUTER CABINET
| a square. |
5. | Drill a pilot hole within the scribed square on the outer casing. Remove |
| the sheet metal within the scribed square with a tin snips or comparable |
| tool.Attention! Do not cut the electrical wires located between the outer |
| casing and the inner shield. |
6. | Insert the 5" x 5" (127mm x 127mm) inner boot through the outer cas- |
| ing. Align the clearance holes on the inner boot with the screw holes |
| on the inner shield. Attach inner boot to inner shield with (2) # 8 x 3/8" |
| (9mm) screws removed in Step 3. |
7. | Place the register over the 5 1/2" (140mm) square opening with the |
| louvers set for the desired direction and mark the mounting holes using |
| the register as a template. |
8. | Drill (2) 1/8" diameter holes in cabinet side and attach the register with |
| (2) #10 x 1" (25mm) provided screws. |
9. | Installation of |
Side outlet kit,
To install
1.Using the inner and outer boots as hole templates, mark and drill (4) 1/8" (3mm) diameter holes in the inner shield and (4) 1/8" (3mm) diameter holes in the cabinet side.
2.Locate and cut a 6 3/4" (171mm) square opening through wall.
3.Attach furnace to wall (see Attaching Furnace to Wall).
4.With furnace in place, after checking alignment of side outlet opening in wall and furnace, place the 9 3/8" x 9 3/8" (238mm x 238mm) side outlet wall plate over outer boot, pass the outer boot through the wall
Page 6
Figure 6
Installing Optional Rear Outlet
Rear outlet kit, 10" (254mm) boot assembly with register,
Attention: Before furnace is attached to the wall, the wall opening for the rear outlet must be cut, in addition to removal of the outer and inner casing knockouts on furnace.
1.The wall opening measurements for the rear outlet are the following.
A.From floor to bottom of wall opening is 10 11/16" (271mm).
B.From bottom of wall opening to top of wall opening is 8 1/2" (216mm).
C.Wall opening width is 12 1/8" (308mm).
2.Scribe a line between the four dimples on the outer casing back to form a square. Drill a pilot hole within the scribed square on the outer casing back. Remove the sheet metal within the scribed square with a tin snips or comparable tool.
3.Remove the (4) #8 x 3/8" (9mm) screws that attach the inner casing close off plate to the inner casing.
4.Insert the privacy shield through the outer casing back and the inner casing back. The privacy shield will be in front of the inner casing back and behind the combustion chamber tubes. Align clearance holes on privacy shield with screw holes on inner casing back. Attach privacy shield to inner casing back with (2) #8 x 3/8" (9mm) provided. Attention:
The (2) #8 x 3/8" (9mm) screws must be inserted from the front of the furnace.
5.Attach furnace to wall.
6.Align clearance holes on 8" x 12" (203mm x 305mm) boot with screw holes on outer casing back and mark boot to be flush with wall surface. Remove boot and cut to proper length.
7.Attach 8" x 12" (203mm x 305mm)boot to outer casing back with (6)