LIGHTING INSTRUCTIONS

FOR YOUR SAFETY READ BEFORE LIGHTING

WARNING: If you do not follow these instructions exactly, a Þre or explosion may result

causing property damage, personal injury or loss of life.

A.This appliance has a pilot which must be lighted by hand. When lighting the pilot, follow these instructions exactly.

B.BEFORE LIGHTING smell all around the appliance area for gas. Be sure to smell next to the ßoor because some gas is heavier than air and will settle on the ßoor.

WHAT TO DO IF YOU SMELL GAS

Do not try to light any appliance.

Do not touch any electrical switch;

do not use any phone in your building.

Immediately call yourgas supplierfrom a neighbor's

phone. Follow the gas supplier's instructions.

If you cannot reach your gas supplier, call the Þre department.

C.Use only your hand to push in or turn the gas control knob. Never use tools. If the knob will not push in or turn by hand, don't try to repair it; call a qualiÞed service technician. Force or attempted repair may result in a Þre or explosion.

D.Do not use this appliance if any part has been under water. Immediately call a qualiÞed service techni- cian to inspect the appliance and to replace any part of the control system and any gas control which has

LIGHTING INSTRUCTIONS

1. STOP! Read the safety information above.

2. S e t t h e t h e r m o s t a t t o l o w e s t s e t t i n g .

3.Turn off all electric power to the appliance (if appli- cable).

4.Remove control access panel (control door).

5. P u s h

i n g a s c o n t r o l

k n o b

s l i g h t-

ly and

turn clockwise

to

"OFF."

GAS CONTROL KNOB SHOWN IN "OFF" POSITION

NOTE: Knobcannotbeturnedfrom"PILOT"to"OFF" unless knob is pushed in slightly. Do not force.

6. Wait ten (10) minutes to clear out any gas. Then smell for gas, including near the ßoor. If you smell gas, STOP! Follow "B" in the safety information above. If you don't smell gas, go to the next step.

7.Find pilot - follow metal tube from gas control. The pilot is mounted on front of main burner.

8.Turn gas control knob coun-

terclockwise to "PILOT."

9.Push in control knob all the

way and hold in. Immediately light the pilot with a match. Continue to hold the control knob in for about one (1) minute after the pilot is lit. Release knob and it will pop back up. Pilot should remain lit. If it goes out, repeat steps 5 through 9.

If knob does not pop up when released, stop and immediately call a qualiÞed service technician or gas supplier.

If the pilot will not stay lit after several tries, turn the gas control knob to "OFF" and call your service technician or gas supplier.

10.Turn gas control knob counterclockwise to "ON."

11. R e p l a c e c o n t ro l a c c e s s p a n e l ( c o n t ro l door).

12.Turn on all electric power to the appliance (if applicable).

13.Set thermostat to desired setting.

TO TURN OFF GAS TO APPLIANCE

1.Set the thermostat to lowest setting.

2.Turn off all electric power (if applicable) to appliance if service is to be performed.

3.Remove control access panel (control door).

4.Push in gas control knob slightly and turn

clockwise to "OFF." Do not force.

5.Replace control access panel (control door).

Page 12

12426-4-0104

Page 12
Image 12
Empire Comfort Systems GWT-50-2, RB) installation instructions Lighting Instructions, Turn clockwise OFF

RB), GWT-50-2 specifications

Empire Comfort Systems GWT-50-2, RB is a versatile and efficient gas wall heater that showcases innovative technology and thoughtful design, making it an ideal heating solution for both residential and commercial spaces. Designed for optimal performance, the GWT-50-2, RB delivers reliable warmth even in the coldest of climates, ensuring comfort without the hassle of traditional heating methods.

One of the defining characteristics of the GWT-50-2, RB is its 50,000 BTU output, providing substantial heating capability. This unit can effectively heat spaces up to 1,000 square feet, making it suitable for larger rooms or open-plan areas. Its compact design and wall-mounted installation save valuable floor space while still offering robust heating power.

Featuring a direct vent design, the heater draws fresh air from outside for combustion and expels exhaust gases, ensuring safe and efficient operation. This design not only enhances efficiency but also protects indoor air quality by minimizing the risk of harmful fumes infiltrating living areas.

The GWT-50-2, RB comes equipped with a robust electronic ignition system, which allows for easy start-up without the need for a standing pilot light. This feature also contributes to energy savings, as the heater can operate only when needed. The advanced thermostat controls allow users to set their preferred temperature, providing tailored comfort and reducing energy consumption.

Another notable feature is the energy-efficient design of the heater, which includes a fan-blower system that circulates warm air throughout the room. This enhances thermal distribution, ensuring that heat reaches every corner of the space without any cold spots.

Additionally, the sleek and stylish appearance of the GWT-50-2, RB allows it to blend harmoniously with various interior decors. Available in multiple finishes, it can be a complementary addition to any home or office environment.

In summary, the Empire Comfort Systems GWT-50-2, RB stands out as a powerful yet efficient heating solution. Its high BTU output, energy-efficient technology, user-friendly controls, and aesthetically pleasing design make it an excellent choice for anyone seeking reliable comfort in their living or working spaces. With Empire's commitment to quality and innovation, users can trust that this gas wall heater will provide comfort and warmth for years to come.