REMOTE BULB CONTROL INSTALLATION INSTRUCTIONS

MODELS

GWT-25 RB, GWT-35 RB, GWT-50 RB

No.

Number

Description

 

 

 

1

GW- 130

Remote Bulb Control Kit

2

R-1224

Remote Bulb Control

3

R-2499

Wire Assembly

4

R-1162

Control Knob

5

R-1720

Plastic Clip (3 Required)

6

R-1223

Instructions

7

R-1578

No. 6-32 x 1/4" (6mm) Screw (2 Required)

 

 

 

INSTRUCTIONS

Note: At the option of the owner, the remote bulb control may be located on the left or right side of the outer casing.

1.Remove remote bulb control from the shipping carton.

2.Remove outer casing assembly from shipping carton.

Note: If wall furnace is already installed, remove outer casing from unit and lay on ßoor with front side down.

3.Attach wire assembly to remote bulb control.

4.Carefully unwind capillary wire on remote bulb control.

5.Remove (3) hole plugs from left or right side of outer casing where remote bulb control is to be installed.

6.Mount remote bulb control to inside of outer casing with (2) No. 6-32 x 1/4" (6mm)screws.

Index Part

Caution: Remote bulb wire routing is important. Wires should be in proper location to avoid damage from being overheated. Incorrect routing of remote bulb control wires may result in damage to wires and incorrect operation of remote bulb control. Follow these instructions and refer to the drawing for proper wire routing.

7.If remote bulb control is located on the right side of the outer cas- ing, carefully bend or loop capillary wire around control. This will enable the sensing bulb to be positioned at the bottom of the unit.

8.Secure sensing bulb on the inside, at the bottom, of the outer casing with (2) plastics clips.

9.Feed the wire assembly down along the inside of the outer casing.

10.Use third plastic clip to secure wire assembly and capillary wire to the casing. (Approximately 24" (610mm) from bottom of unit.)

11.Attach control knob to remote bulb control.

12.Install furnace according to instructions in the Installation Instruc- tions and Owner's Manual.

Note: If wall furnace is already installed, secure outer casing to unit.

13.Attach wire assembly to gas valve at the "TH" and "TH/TP" terminals on the Robertshaw valve.

Attach wire assembly to gas valve at the "THERMO" terminals on the ITT valve. If the wire assembly has two 1/4" (6mm) female connectors, the connectors should be cut off the wire assembly. Strip and bare the wires and attach wires to the "THERMO" terminals. Note: This remote bulb control is connected to the gas valve the same way as a wall thermostat. Any references made to the ther- mostat in the lighting instructions would also apply to the remote bulb control.

TO VENT SAFETY

TO THERMOPILE

TO REMOTE BULB

12426-4-0104

Page 17

Page 17
Image 17
Empire Comfort Systems RB), GWT-50-2 installation instructions Remote Bulb Control Installation Instructions, Models

RB), GWT-50-2 specifications

Empire Comfort Systems GWT-50-2, RB is a versatile and efficient gas wall heater that showcases innovative technology and thoughtful design, making it an ideal heating solution for both residential and commercial spaces. Designed for optimal performance, the GWT-50-2, RB delivers reliable warmth even in the coldest of climates, ensuring comfort without the hassle of traditional heating methods.

One of the defining characteristics of the GWT-50-2, RB is its 50,000 BTU output, providing substantial heating capability. This unit can effectively heat spaces up to 1,000 square feet, making it suitable for larger rooms or open-plan areas. Its compact design and wall-mounted installation save valuable floor space while still offering robust heating power.

Featuring a direct vent design, the heater draws fresh air from outside for combustion and expels exhaust gases, ensuring safe and efficient operation. This design not only enhances efficiency but also protects indoor air quality by minimizing the risk of harmful fumes infiltrating living areas.

The GWT-50-2, RB comes equipped with a robust electronic ignition system, which allows for easy start-up without the need for a standing pilot light. This feature also contributes to energy savings, as the heater can operate only when needed. The advanced thermostat controls allow users to set their preferred temperature, providing tailored comfort and reducing energy consumption.

Another notable feature is the energy-efficient design of the heater, which includes a fan-blower system that circulates warm air throughout the room. This enhances thermal distribution, ensuring that heat reaches every corner of the space without any cold spots.

Additionally, the sleek and stylish appearance of the GWT-50-2, RB allows it to blend harmoniously with various interior decors. Available in multiple finishes, it can be a complementary addition to any home or office environment.

In summary, the Empire Comfort Systems GWT-50-2, RB stands out as a powerful yet efficient heating solution. Its high BTU output, energy-efficient technology, user-friendly controls, and aesthetically pleasing design make it an excellent choice for anyone seeking reliable comfort in their living or working spaces. With Empire's commitment to quality and innovation, users can trust that this gas wall heater will provide comfort and warmth for years to come.