SECTIONAL PARTS FOR GAS STOVE

SECTIONAL PARTS FOR GAS STOVE

SP-010

SP-011

SP-012

SP-064

 

SP-063 SP-065

SP-066

S-1111

S-1122

S-1133

S-1144

 

S-1155 S-1166

S-1177

SP-067

SW2-1

SW3-1

SP-013

 

SP-014 SP-015

P-220 P-219

S-1188

S-1211

 

S-1222

S-1233

 

S-1244 S-1255

SP--1266221

SP-034

RS--33371288

R-3445

SP--1300028

RS--33391 11

SP-1322-055

SP-062

S-1277

S-1299

S-1333

 

 

SSP-1366-016

S-1377

S-1380

S-1389

 

 

SP-010

One-Burner Top

SP-013

One-Burner Drip Pan

SP-028

Burner hanger

SP-011

Two-Burner Top

SP-014

Two-Burner Drip Pan

R-3339

Grate

SP-012

Three-Burner Top

SP-015

Three-Burner Drip Pan

SP-055

Round Burner

SP-076

One-Burner Semi-Enclosed Frame*

P-220

One-Hole Manifold

SP-062

Star Burner

SP-064

Two-Burner Semi-Enclosed Frame

P-219

Two Hole Manifold

SP-016

6" Low Leg

SP-063 Three Burner Semi-Enclosed Frame

P-221

Three Hole Manifold

S-1377

28" High Leg

SP-065

One-Burner Mini-Stove Frame

SP-034

Manifold Clamp

S-1380

32" High Leg

SP-066

Two-Burner Mini-Stove Frame

R-3337

Knob

S-1388

Leg Brace for 32" High

SP-067

Three-Burner Mini-Stove Frame

R-3445

Gas Valve

SW2-1

Two-Burner Windscreen

* Not Shown

 

 

SW3-1

Three-Burner Windscreen

 

 

 

 

 

 

 

WARNING: NEVER PUT HANDS OR

 

FACE

 

DIRECTLY OVER BURNER WHILE

 

LIGHTING

 

You may adjust valve setting at this time.

 

The flame should show a greenish

 

blue inner cone with a slight yellow BURNER

 

tip. If necessary, you can make an

 

adjustment by turning the hood of the LEG

SHUTTER

 

AIR￿

valve in a counterclockwise direction

 

until the flame performance is

 

satisfactory. See other side for further in-

 

structions regarding valve setting.

 

GRATE

 

CAUTION: Orifice HOODS must again be turned down, if the gas

 

STOVE

 

stove is to be used on LP gas after it has once been adjusted for other

 

 

 

 

gases.

MANIFOLD￿

 

GAS ENTRANCE

CLAMP

 

 

MANIFOLD

 

 

 

 

DUST COVER

GAS￿

ADJUSTING PIN

STEM

VALVE

 

DRIP￿

HOLE IN￿

 

ADJUSTING PIN

 

PAN

 

KNOB

ADJUSTING HOOD

 

 

ADJUSTING HOOD￿ VALVE BODY

SHOULDER

DO not tamper with or attempt repairs on the burners, frames valves, or

UNDER NO CIRCUMSTANCES SHOULD ANY ALTERATIONS

LP cylinder. Allow only qualified LP Gas Dealers to make repairs and

BE MADE TO THE GAS VALVE AND BURNER ASSEMBLY.

adjustments.

 

Always close LP cylinder valve after use. Always use and store bottle in

Warranty

an upright position. Never store or transport these cylinders in an

occupied enclosure.

Empire Comfort Systems, Inc. makes no claim of fitness of this prod-

Adjustment Instructions-Universal Gas Valve

uct for a particular purpose or use and assumes no liability for damages

Your portable gas stove is furnished with A.G.A. listed Universal type

resulting from the use of the product. Liability of the manufacturer in

Gas Valve. This valve is designed for use with (Liquefied Petroleum

any event is limited to the amount of the original purchase price of this

LPG), Natural or Manufactured Gas. When gas plate is installed the

product. This warranty applies only to the use of the product in

valve should be set for the kind of gas to be used.

accordance with the manufacturer's operating instructions, and remains

The universal valve is adjusted for the various gases by turning the

in force only so long as the product remains in its original

ADJUSTING HOOD. To turn HOOD use wrench on HOOD SHOUL-

configuration. This warranty does not apply to products that have been

DER. This may be done after gas stove is assembled as HOOD

altered or repaired by outside agents, abused, damaged through neglect,

SHOULDER is easily accessible.

misuse, or accident, or to products that have been used in any way other

1. This valve is shipped from the factory adjusted for LP gas. If LP gas

than in accordance with manufacturer's operating instructions. There

are no other warranties, expressed or implied, pertaining to this product

is to be used, no adjustments should be necessary. Orifice HOOD

or any other product sold by us. Empire Comfort Systems, Inc. neither

can be open slightly to get desired flame.

assumes any responsibility in its behalf for operation of this or any

2. For use with Natural or Manufactured gas open HOOD until the

other product manufactured or sold.

proper amount of gas is fed to each burner. When properly adjusted

 

the flame should have greenish blue inner cones about one-half inch

 

long. An unnecessary high flame is wasteful and inefficient.

 

3. The air shutter for each burner should be adjusted so the flame burns

 

clean without blowing. After you obtain the correct setting or the air

 

shutter, lock in place by tightening the air shutter screw.

Page 2

CAUTION: MAXIMUM WORKING PRESSURE 1/2 P.S.I. 11-INCH WATER COLUMN

R-3088

 

(LOW PRESSURE REGULATOR IS REQUIRED)

 