INSTALLING AS A VENTED APPLIANCE

Notice (Damper Clamp Installation)

When installing your log set as a vented installation the damper clamp must be used.

When installing your log set as a vent-free installation the damper clamp can be used to eliminate the potential for odors when burn- ing the logs for the first time.

Installing Damper Clamp (Figure 9)

Remove all ashes or other debris from the fireplace. If the fireplace is equipped with an ash dump be sure to seal the door with furnace cement or high temperature silicone. Be sure to check the damper for proper operation and verify that the flue passageway is open.

Place the clamp over the lip of the damper and tighten the hold down bolt until the clamp is securely attached to the damper. This will prevent the damper from accidentally closing.

Manual and millivolt controlled gas logs may be installed as a vented decorative log set in compliance with ANSI Z21.60 and National Fuel Gas Code. When the gas logs are operated with the damper open, non-combustible material and minimum mantel requirements do not apply.

Figure 9

BEFORE FULLY INSTALLING THE APPLIANCE

Turn off the gas supply to the fireplace or firebox.

Seal any fresh air vents and/or ash clean-out doors located on the floor or wall of the fireplace. If left unsealed, drafting may cause pilot outage or sooting. Use a heat resistant sealant. Do not seal the chimney flue damper.

Before installing in a solid fuel burning fireplace, the chimney flue and firebox must be cleaned of soot, creosote, ashes and loose paint by a qualified chimney cleaner.

You must secure the gas log heater to the fireplace floor. If not, the entire unit may move when you adjust the controls. Movement of unit may cause shifting of the gas logs which leads to sooting and improper burning. Grate movement could cause a gas leak.

Special care is required if you are installing the unit into a sunken fireplace. You must raise the fireplace floor to allow access to gas log controls. This will insure adequate air flow and guard against sooting. Raise the fireplace floor using noncombustible materials.

Assembly Procedure: (Figure 10)

1.Center the gas log unit in the fireplace or firebox. Make certain the front feet of the grate sit inside the front edge of the fireplace or firebox.

2.An anchor hole is provided in the two bottom side members of the grate frame. After centering the grate correctly, mark the hole positions on the fireplace/firebox floor. Drill two (2) 5/32" diameter holes approximately 1-1/2" deep for masonry screws or 1/8" hole for sheet metal screws.

3.Anchor the grate to the fireplace/firebox floor using the screws provided. Refer to Figure10.

Proper installation of the grate is essential to prevent any move- ment of the gas logs and controls during operation.

Figure 10

Page 10

18954-0-0705

Page 10
Image 10
Empire Comfort Systems VFSV-16-3, VFSV-24-3 Installing AS a Vented Appliance, Before Fully Installing the Appliance

VFSV-30-3, VFSM -30-3, VFSR-30-3, VFSV-24-3, VFSR-24-3 specifications

Empire Comfort Systems offers a range of high-performance gas-fired vent-free space heaters, including the VFSM-24-3, VFSV-24-3, VFSM-30-3, VFSV-16-3, and VFSM-18-3 models. These heaters are designed to provide effective, efficient, and environmentally friendly heating solutions for homes and businesses.

One of the key features of these models is their vent-free technology, which allows them to operate without the need for external venting. This design not only simplifies installation but also maximizes heat output in enclosed spaces, making them ideal for areas where traditional heating methods are impractical. The units are equipped with a safety pilot system that automatically shuts off the gas flow in case of a malfunction, ensuring safety for users.

The VFSM and VFSV series offer a variety of heating capacities, ranging from 16,000 to 30,000 BTUs, catering to different room sizes and heating requirements. The adjustable heat settings allow users to customize their heating experience based on their comfort needs. Additionally, the units feature a thermostat control option, which provides even greater ease of use and energy efficiency.

Energy efficiency is another hallmark of Empire’s vent-free heaters, as they utilize 99% of the gas consumed for heating. This high efficiency translates into lower energy bills for consumers. Furthermore, these heaters produce minimal emissions, making them an environmentally conscious choice for heating.

The VFSM and VFSV models are available in a range of stylish designs and finishes, allowing them to blend seamlessly with various home decors. Their compact sizes mean they can be installed in tight spaces or mounted on walls, optimizing room layouts without sacrificing heating performance.

Another notable characteristic is the option for remote control operation. This feature provides added convenience, allowing users to adjust settings from across the room. With their robust construction and user-friendly features, the VFSM-24-3, VFSV-24-3, VFSM-30-3, VFSV-16-3, and VFSM-18-3 models stand out as reliable solutions for efficient heating needs, ensuring comfort during the cold months while prioritizing safety and environmental considerations.