Enerco MH170FAVT owner manual General Hazard Warning, Contents, Specifications

Models: MH170FAVT

1 8
Download 8 pages 40.26 Kb
Page 2
Image 2
GENERAL HAZARD WARNING:

WARNING:

CONTENTS YOUR SAFETY IS IMPORTANT TO YOU AND TO OTHERS, SO PLEASE READ THESE INSTRUCTIONS BEFORE YOU OPERATE THIS HEATER.

GENERAL HAZARD WARNING:

SPECIFICATIONS FAILURE TO COMPLY WITH THE PRECAUTIONS AND INSTRUCTIONS PROVIDED WITH THIS HEATER, CAN RESULT IN DEATH, SERIOUS BODILY INJURY AND PROPERTY LOSS OR DAMAGE FROM HAZARDS OF FIRE, EXPLOSION, BURN, ASPHYXIATION, CARBON MONOX- IDE POISONING, AND/OR ELECTRICAL SHOCK.

Manual background ONLY PERSONS WHO CAN UNDERSTAND AND FOLLOW THE INSTRUCTIONS SHOULD USE OR SERVICE THIS HEATER.

Manual background IF YOU NEED ASSISTANCE OR HEATER INFORMATION SUCH AS AN INSTRUCTIONS MANUAL, LABELS, ETC. CONTACT THE MANUFACTURER.

WARNING:

Manual background NOT FOR HOME OR RECREATIONAL VEHICLE USE

WARNING:

Manual background FIRE, BURN, INHALATION, AND EXPLOSION HAZARD. KEEP SOLID COMBUSTIBLES, SUCH AS BUILDING MATERIALS, PAPER OR CARDBOARD, A SAFE DIS- TANCE AWAY FROM THE HEATER AS RECOMMENDED BY THE INSTRUCTIONS NEVER USE THE HEATER IN SPACES WHICH DO OR MAY CONTAIN VOLATILE OR AIRBORNE COMBUSTIBLES, OR PRODUCTS SUCH AS GASOLINE, SOLVENTS, PAINT THINNER, DUST PAR- TICLES OR UNKNOWN CHEMICALS.

WARNING:

Manual background The State of California requires the following warning:

COMBUSTION BY-PRODUCTS PRODUCED WHEN USING THIS PRODUCT CONTAIN CARBON MONOXIDE, A CHEMICAL KNOWN TO THE STATE OF CALIFORNIA TO CAUSE CANCER AND BIRTH DEFECTS (OR OTHER REPRODUCTIVE HARM).

CONTENTS

 

Specifications

2

Operating Precautions

3

Safety Precations

3

Odor Fade Warning

4

Operating Instructions

4

Storage & Service

5

Wiring Diagram

6

Lighting Instructions

5

Parts List

67

Exploded View Drawing

7

SPECIFICATIONS

MODEL NO.

............................................. MH170FAVT

GAS TYPE

Propane

BTU RATING.

......................... 125,000-170,000 BTU/hr

 

(36.6 - 49.8 kW)

GAS SUPPLY PRESSURE TO REGULATOR .....................

Maximum: Bottle Pressure, Minimum: 5 psig (34.5 kPa)

REGULATOR OUT

28" WC (6.97 kPa)

ELECTRICAL INPUT

115V, 60 Hz, 1Ø, 3a

IGNITION

Direct Spark, interrupted type

PRIMARY FLAME CONTROL ..

SolidState,10-15 sec. timing

HIGH TEMPERATURE CONTROL

.................... 240°F (116°C)

Minimum Ambient Temp. Rating: 0°F (-17.8°C)

FUEL CONSUMPTION

5.8 - 7.9 lbs/hr

 

 

(2.6 - 3.6 kg/hr)

FUEL ORIFICE PORT NO.:

........................................

18

FUEL ORIFICE PORT SIZE:

...............................

0.80MM

HEATED AIR OUTPUT:

450 CFM (12.74 CU M/M)

Mr. Heater Forced-Air Propane Construction Heater

2

Operating Instructions and Owner’s Manual

Page 2
Image 2
Enerco MH170FAVT owner manual General Hazard Warning, Contents, Specifications