HOW MUCH HEAT DO I REQUIRE?
For economy, it is important to match input to that required. But heat requirements often vary. For example, it usually takes a lot more heat to get things warm than it does to keep them that way. Likewise, outside air temperature ususally changes during the day so you may need more heat at night than you do in the daytime. An approximation of the heat required can be found by using the chart below.
BTU'S PER HOUR REQUIRED
Cubic feet |
| Temperature Rise Required (oF)* | |||
of space to |
|
|
|
|
|
|
|
|
|
| |
be heated |
| 20o | 30o | 40o | 50o |
5,000 | 14,000 | 20,000 | 27,999 | 34,000 | |
7,000 | 19,000 | 28,000 | 38,000 | 47,000 | |
10,000 | 27,000 | 40,000 | 54,000 | 67,000 | |
15,000 | 40,000 | 60,000 | 80,000 | 100,000 | |
20,000 | 54,000 | 80,000 | 107,000 | 133,000 | |
30.000 | 80,000 | 120,000 | 160,000 | 200,000 | |
50,000 | 133,000 | 200,000 | 266,000 | 333,000 | |
|
|
|
|
|
|
WARNING: When using a thermostat controled heater, its exit area should be protected from personnel and warnings posted of sudden startup.
Recommended Minimum Gauge for Cord Extensions
Wire Gauge Chart A.W.G.
Name |
|
|
|
|
Plate 120V |
| Cord Length in Feet |
| |
Amps. | 25 | 50 | 100 | 150 |
|
|
|
|
|
18 | 16 | 14 | 12 | |
18 | 16 | 12 | 10 | |
18 | 14 | 12 | 10 | |
16 | 14 | 10 | 8 | |
16 | 12 | 10 | 8 |
Model-MH170FAVT
WIRING DIAGRAM
| COLOR CODE |
| LEGEND | |
|
|
|
|
|
B | BLACK | R RED |
| TERMINAL BOARD |
L | BLUE | W WHITE | YY | Y TERMINAL |
G GREEN |
|
| MALE CONN | |
O ORANGE |
| Y FEMALE CONN | ||
|
|
|
|
|
If any original wiring as supplied by the heater must be replaced, it must be replaced with type AWG 105° C wire or its equivalent except as indicated
(*type
MH170FAVT - WIRING CHART
PART |
|
|
|
|
NO. | COLOR | LENGTH | FROM | TO |
|
|
|
|
|
1100 | White | 7" | Valve | Terminal Block |
1040 | Black | 6" | On/Off Switch | Terminal Block |
1226 | 16 1/2" | High Limit Switch | Valve | |
1226 | 16 1/2" | High Limit Switch | Terminal Block | |
1070 | Orange | 11" | Flame Control | Spark Plug |
|
|
| (Ignition) |
|
1959 | Green | 7" | Flame Control | Ground |
|
|
| (Harness) |
|
1959 | Red | 7" | Flame Control | Terminal Block |
|
|
| (Harness) |
|
1959 | White | 6" | Flame Control | Terminal Block |
|
|
| (Harness) |
|
1959 | Black | 6" | Flame Control | Terminal Block |
|
|
| (Harness) |
|
Mr. Heater | 6 | Operating Instructions and Owner’s Manual |