Enerco How Much Heat Do I Require?, Btus Per Hour Required, MH170FAVT - WIRING CHART

Models: MH170FAVT

1 8
Download 8 pages 40.26 Kb
Page 6
Image 6
HOW MUCH HEAT DO I REQUIRE?

HOW MUCH HEAT DO I REQUIRE?

For economy, it is important to match input to that required. But heat requirements often vary. For example, it usually takes a lot more heat to get things warm than it does to keep them that way. Likewise, outside air temperature ususally changes during the day so you may need more heat at night than you do in the daytime. An approximation of the heat required can be found by using the chart below.

BTU'S PER HOUR REQUIRED

Cubic feet

 

Temperature Rise Required (oF)*

of space to

 

 

 

 

 

 

 

 

 

 

be heated

 

20o

30o

40o

50o

5,000

14,000

20,000

27,999

34,000

7,000

19,000

28,000

38,000

47,000

10,000

27,000

40,000

54,000

67,000

15,000

40,000

60,000

80,000

100,000

20,000

54,000

80,000

107,000

133,000

30.000

80,000

120,000

160,000

200,000

50,000

133,000

200,000

266,000

333,000

 

 

 

 

 

 

WARNING: When using a thermostat controled heater, its exit area should be protected from personnel and warnings posted of sudden startup.

Recommended Minimum Gauge for Cord Extensions

Wire Gauge Chart A.W.G.

Name

 

 

 

 

Plate 120V

 

Cord Length in Feet

 

Amps.

25

50

100

150

 

 

 

 

 

5-6

18

16

14

12

6-8

18

16

12

10

8-12

18

14

12

10

10-12

16

14

10

8

12-14

16

12

10

8

Model-MH170FAVT

WIRING DIAGRAM

 

COLOR CODE

 

LEGEND

 

 

 

 

 

B

BLACK

R RED

 

TERMINAL BOARD

L

BLUE

W WHITE

YY

Y TERMINAL

G GREEN

 

 

MALE CONN

O ORANGE

 

Y FEMALE CONN

 

 

 

 

 

If any original wiring as supplied by the heater must be replaced, it must be replaced with type AWG 105° C wire or its equivalent except as indicated

(*type SF2-200, **SGI 250° C).

MH170FAVT - WIRING CHART

PART

 

 

 

 

NO.

COLOR

LENGTH

FROM

TO

 

 

 

 

 

1100

White

7"

Valve

Terminal Block

1040

Black

6"

On/Off Switch

Terminal Block

1226

Red-(Hi-Temp)

16 1/2"

High Limit Switch

Valve

1226

Red-(Hi-Temp)

16 1/2"

High Limit Switch

Terminal Block

1070

Orange

11"

Flame Control

Spark Plug

 

 

 

(Ignition)

 

1959

Green

7"

Flame Control

Ground

 

 

 

(Harness)

 

1959

Red

7"

Flame Control

Terminal Block

 

 

 

(Harness)

 

1959

White

6"

Flame Control

Terminal Block

 

 

 

(Harness)

 

1959

Black

6"

Flame Control

Terminal Block

 

 

 

(Harness)

 

Mr. Heater Forced-Air Propane Construction Heater

6

Operating Instructions and Owner’s Manual

Page 6
Image 6
Enerco MH170FAVT How Much Heat Do I Require?, Btus Per Hour Required, Recommended Minimum Gauge for Cord Extensions