E N
(B) Power Management Signalling
Power Management Definition
| VESA DPMS |
|
| POWER SAVING STATES | ||
MODE | VIDEO |
|
| POWER USED | POWER SAVING(%) | |
|
|
|
|
|
| |
ON | Active | Yes | Yes | < 100 Watts | 0 % | |
|
|
|
|
|
|
|
Blanked | No | Yes | < | 15 Watts | > 80 % | |
|
|
|
|
|
|
|
Suspend | Blanked | Yes | No | < | 15 Watts | > 80 % |
|
|
|
|
|
|
|
OFF | Blanked | No | No | < | 5 Watts | > 90 % |
|
|
|
|
|
|
|
Note: The video will be blanked and the power LED color will change into following colors whenever the monitor goes into power
management status. |
|
|
Green LED light | - | "Normal" operation |
Amber LED light | - "Stand by" or "Suspend" mode | |
Amber LED light | - | "OFF" mode |
This monitor is ENERGY STAR® compliant when used with a computer equipped with DPMS.
As an ENERGY STAR® Partner, PCEC has determined that this product meets the ENERGY STAR® guidelines for energy efficiency.
Remark:
The transition time from "on" mode to any power down mode will take around 5 seconds.
The recovery time from "stand by" or "suspend" mode to "ON" mode will take around 3 seconds.
10