Energy Tech Laboratories 105E manual B Power Management Signalling, Mode, Video, H-Sync, V-Sync

Models: 105E

1 14
Download 14 pages 55.84 Kb
Page 10
Image 10
(B) Power Management Signalling

E N

(B) Power Management Signalling

Power Management Definition

 

VESA DPMS

 

 

POWER SAVING STATES

MODE

VIDEO

H-SYNC

V-SYNC

POWER USED

POWER SAVING(%)

 

 

 

 

 

 

ON

Active

Yes

Yes

< 100 Watts

0 %

 

 

 

 

 

 

 

Stand-by

Blanked

No

Yes

<

15 Watts

> 80 %

 

 

 

 

 

 

 

Suspend

Blanked

Yes

No

<

15 Watts

> 80 %

 

 

 

 

 

 

 

OFF

Blanked

No

No

<

5 Watts

> 90 %

 

 

 

 

 

 

 

Note: The video will be blanked and the power LED color will change into following colors whenever the monitor goes into power

management status.

 

 

Green LED light

-

"Normal" operation

Amber LED light

- "Stand by" or "Suspend" mode

Amber LED light

-

"OFF" mode

This monitor is ENERGY STAR® compliant when used with a computer equipped with DPMS.

As an ENERGY STAR® Partner, PCEC has determined that this product meets the ENERGY STAR® guidelines for energy efficiency.

Remark:

MODE The transition time from "on" mode to any power down mode will take around 5 seconds.

VIDEO The recovery time from "stand by" or "suspend" mode to "ON" mode will take around 3 seconds.