England's Stove Works 55-TRPEP, 55-SHPEP, 25-EP operation manual Replacing Components

Models: 55-TRPEP 25-EP 55-SHPEP

1 50
Download 50 pages 48 Kb
Page 39
Image 39

REPLACING COMPONENTS

Convection Blower

1.Before beginning any component replacement, be certain the unit is unplugged and thoroughly cooled down.

2.Remove the right side panel as previously detailed in this manual on Page. 32 in the “Exhaust Blower Cleaning” section.

3.Detach the convection blower from the wiring harness before loosening the four screws which secure it to the convection shroud of the stove.

4.After loosening and removing the four screws which hold the blower to the stove, remove the blower from the stove.

5.Installation of the new blower is performed in reverse of removal; remember to reconnect the new blower to the wiring harness before reinstalling the side panel.

Combustion Blower

1.Before beginning any component replacement, be certain the unit is unplugged and thoroughly cooled down.

2.Remove the left side panel as previously detailed on pg. 32.

3.Disconnect the venting system from the exhaust blower, and disconnect the exhaust blower from the stove wiring harness. Loosen and remove the thermal sensor screw on the top of the exhaust blower outlet using a 5/16” wrench.

4.Loosen and remove all five screws which hold the exhaust blower to the exhaust blower tube. Once the screws have been removed, the blower can be lifted up and out of the stove.

5.Reinstallation is the exact opposite of the steps above; however be certain to check the condition of the exhaust blower gasket and replace if necessary.