APPENDIX A: EPIM SPECIFICATIONS

power output at 25C equals -16.4 dBm. For a 4C temperature increase, multiply the typical coefficient (-0.15 dBm) by four, and add the result to typical output power (4 x -0.15 dBm + -16.4 dBm = -17.0 dBm)

Parameter

Typical

 

 

Transmit Power:

-15.1 dBm

 

 

Transmit Budget:

14.4 dBm

 

 

 

 

Receive Sensitivity:

-29.5 dBm

 

 

 

 

Maximum Receive

-6.99 dBm

Power:

 

 

 

 

 

Bit Error Rate:

Better than

 

10-10

Note: The above transmitter power levels and receive sensitivity levels represent Peak Power Levels after optical overshoot. You must use a Peak Power Meter to correctly compare the above values to those you measure on any particular port. If you measure Power Levels with an Average