MQL • STANDARD & OPTIONAL FEATURES
STANDARD FEATURES | Electrical | Filters and Filter Rack |
Construction | • Fan motor wired and terminated | • 4" high efficiency pleated filters |
• Modular design facilitates retrofit | to junction box | (65, 85, and 95%) |
• Galvanized steel cabinet | • All units cETL listed in compliance | • Mixing box with filter sections |
construction | with UL/ANSI 1995 | (flat or |
• 1" thick fiberglass insulation, | Electric Heat Section | arrangements) |
glued and pinned in place | Inlet Damper Section | |
• Gasketed, removable access | • Draw Thru or Blow Thru | |
panels sized for easy handling | configurations | • Factory assembled and installed |
• Left and right hand arrangement | • Factory mounted electric heater | • Heavy gauge galvanized steel |
• Access panels on all sections | with single point power connec- | formed blade dampers |
Fan Assembly | tion, ETL listed as an assembly | • Low leak dampers with extruded |
OPTIONAL FEATURES | vinyl blade seals and flexible | |
• Single | metal jamb seals | |
tions | Construction | • Medium and large inlet plenums |
• Statically and dynamically | • Double wall (solid or perforated) | with |
balanced | cabinets | • Parallel blade operation |
• Solid steel shafting | • Stainless steel IAQ drain pan with | • Interconnecting damper linkage |
• Ball bearings with a minimum | stainless steel male pipe threaded | • Damper actuator (modulating |
design average life (L50) of | connection | from 100% OA to 100% RA) |
100,000 hours | • Fan discharge arrangements | Additional Modules |
• Fan decks with internal vibration | • Scrim reinforced foil faced | |
isolation | insulation | • Face and bypass with medium |
Fan Motor and Drive | • Hinged access panels with lift and | and small coils |
turn fasteners | • Economizer sections | |
• Single speed ODP motors | • 4" Base rails with rigging slots | • Discharge plenums |
• 1750 RPM single speed, 60 Hertz | factory assembled and installed | • Access sections |
• Single phase motors with | Fan Motor and Drive | • High efficiency filter sections |
inherent thermal protection | Electrical | |
• Three phase motors | • Direct drive plug fans with inter- | |
• Standard cross section | nal | • Motor wiring in conduit |
drive with 1.2 service factor | • TEFC motors | • Single phase fan control package |
• Adjustable pitch motor pulley | • High efficiency motors | • Three phase fan control package |
and fixed pitch blower pulley | • | • Door interlocking disconnect |
Coils | • Variable frequency drives, factory | switch |
installed (mounted and wired) | • Fusing (main or per stage) | |
• 1/2" O.D. seamless copper tubes | • Motor starter (contactor with | • Hand off auto switch (HOA) |
• G90 steel coil casings | overload for three phase; contac- | • Frequency inverters |
• Collared aluminum fins | tor for single phase), factory | • Electric heat interlock relay |
• Manual air vent plug on all water | installed (mounted and wired) | • Relays, transformers, etc. |
coils | • Return FC and plug fan sections |
|
• 300 PSIG Working Pressure at | Coils |
|
200°F |
| |
• Copper ODM sweat connections | • 3, 4, 6 and 8 row chilled water or |
|
• 0.016" tube wall on water and | R22 DX coils |
|
evaporator coils | • Up to 4 rows hot water or up to |
|
• 0.025" tube wall on steam coils | 2 rows standard steam |
|
Filters and Filter Rack | • Heating coil in preheat or reheat |
|
position |
| |
• Hinged side access flat filter rack | • Coil connections opposite |
|
• 2" pleated filters (30%) | handing |
|
| • Stainless steel coil casings |
|
| • 0.025" tube wall thickness |
|
| • Auto air vents |
|
Printed on recycled paper
Catalog: ET102.19-EG1 (810) Supersedes Catalog: ET102.19-EG1 (410)
© 2010 Johnson Controls, Inc. P.O. Box 423, Milwaukee, WI 53201 Printed in USA www.johnsoncontrols.com