Enviro 170S5FG manual Mql Electric Heat

Models: 170S5FG

1 30
Download 30 pages 62.72 Kb
Page 8
Image 8
MQL • ELECTRIC HEAT

MQL • ELECTRIC HEAT

 

UNIT

 

 

 

 

 

 

BLOW-THRU ELECTRIC HEAT

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Unit Size

 

 

 

 

 

 

 

 

 

 

 

VOLTAGE

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

02

03

04

06

08

10

 

12

 

14

 

17

AND PHASE

 

 

 

 

 

 

Min

Max

Min

Max

Min

Max

Min

Max

Min

Max

Min

Max

Min

 

Max

Min

 

Max

Min

 

Max

 

115

kW

3

5

3

5

4

5

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Phase

AMPs

26.1

43.5

26.1

43.5

34.8

43.5

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

208

AMPs

14.4

43.3

14.4

43.3

19.2

43.3

28.8

43.3

33.7

43.3

 

 

 

 

 

 

 

 

 

 

 

 

 

kW

3

9

3

9

4

9

6

9

7

9

 

 

 

 

 

 

 

 

 

 

 

Single

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

230

kW

3

11

3

11

4

11

6.0

11

7

11

9

11

 

 

 

 

 

 

 

 

 

AMPs

13.0

47.8

13.0

47.8

17.4

47.8

26.1

47.8

30.4

47.8

39.1

47.8

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

277

kW

3

13

3

13

4

13

6.0

13

7

13

9

13

 

 

 

 

 

 

 

 

 

 

AMPs

10.8

46.9

10.8

46.9

14.4

46.9

21.7

46.9

25.3

46.9

32.5

46.9

 

 

 

 

 

 

 

 

 

 

208

kW

3

13

3

16

4

16

4.0

16

7

16

9

16

12

 

16

14

 

16

 

 

 

Phase

AMPs

8.3

36.1

8.3

44.4

11.1

44.4

11.1

44.4

19.4

44.4

25.0

44.4

33.3

44.4

38.9

44.4

 

 

 

230

AMPs

7.5

32.6

7.5

45.2

10.0

45.2

10.0

45.2

17.6

45.2

22.6

45.2

30.1

 

45.2

35.1

 

45.2

40.2

 

45.2

 

 

kW

3

13

3

18

4

18

4.0

18

7

18

9

18

12

 

18

14

 

18

16

 

18

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Three

460

kW

3

13

3

20

4

26

4.0

26

7

38

9

38

12

 

38

14

 

38

16

 

38

AMPs

3.8

16.3

3.8

25.1

5.0

32.6

5.0

32.6

8.8

47.7

11.3

47.7

15.1

 

47.7

17.6

 

47.7

20.1

 

47.7

 

 

 

 

 

575

kW

3

13

3

20

4

26

4.0

26

7

46

9

46

12

 

46

14

 

46

16

 

46

 

AMPs

3.0

13.1

3.0

20.1

4.0

26.1

4.0

26.1

7.0

46.2

9.0

46.2

12.0

 

46.2

14.1

 

46.2

16.1

 

46.2

Notes:

1.Blow thru heaters can have a maximum of two stages.

2.VFD controllers cannot be supplied with blow thru heaters.

3.Specific kW ratings are available within the ranges shown. Refer to selection program.

4.Heaters above 480v must utilize one time secondary limits only.

 

UNIT

 

 

 

 

 

 

DRAW-THRU ELECTRIC HEAT

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Unit Size

 

 

 

 

 

 

 

 

 

 

 

VOLTAGE

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

02

03

04

06

08

10

 

12

 

14

 

17

AND PHASE

 

 

 

Min

Max

Min

Max

Min

Max

Min

Max

Min

Max

Min

Max

Min

 

Max

Min

 

Max

Min

 

Max

 

 

 

 

 

 

 

115

kW

3

5

3

5

4

5

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Phase

AMPs

26.1

43.5

26.1

43.5

34.8

43.5

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

208

kW

3

10

3

10

4

10

6.0

16

7

16

9

20

 

 

 

 

 

 

 

 

 

AMPs

14.4

48.1

14.4

48.1

19.2

48.1

28.8

76.9

33.7

76.9

43.3

96.2

 

 

 

 

 

 

 

 

 

Single

230

kW

3

11

3

11

4

11

6.0

18

7

18

9

22

 

 

 

 

 

 

 

 

 

AMPs

13.0

47.8

13.0

47.8

17.4

47.8

26.1

78.3

30.4

78.3

39.1

95.7

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

277

kW

3

13

3

13

4

13

6.0

22

7

22

9

26

 

 

 

 

 

 

 

 

 

 

AMPs

10.8

46.9

10.8

46.9

14.4

46.9

21.7

79.4

25.3

79.4

32.5

93.9

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

208

kW

3

13

3

20

4

26

4.0

26

7

28

9

34

12

 

46

14

 

46

16

 

46

Phase

AMPs

8.3

36.1

8.3

55.5

11.1

72.2

11.1

72.2

19.4

77.7

25.0

94.4

33.3

 

127.7

38.9

 

127.7

44.4

 

127.7

 

 

 

 

230

kW

3

13

3

20

4

26

4.0

26

7

32

9

34

12

 

49

14

 

49

16

 

49

AMPs

7.5

32.6

7.5

50.2

10.0

65.3

10.0

65.3

17.6

80.3

22.6

85.3

30.1

123.0

35.1

123.0

40.2

123.0

Three

460

kW

3

13

3

20

4

26

4.0

26

7

52

9

64

12

 

76

14

 

88

16

 

96

AMPs

3.8

16.3

3.8

25.1

5.0

32.6

5.0

32.6

8.8

65.3

11.3

80.3

15.1

 

95.4

17.6

 

110.4

20.1

 

120.5

 

 

 

 

 

575

kW

3

13

3

20

4

26

4.0

26

7

52

9

64

12

 

76

14

 

88

16

 

96

 

AMPs

3.0

13.1

3.0

20.1

4.0

26.1

4.0

26.1

7.0

52.2

9.0

64.3

12.0

 

76.3

14.1

 

88.4

16.1

 

96.4

 

 

 

 

 

Notes:

1.Draw thru heaters can have a maximum of four stages.

2.All heaters that have an AMP draw greater than 48 AMPs will have a minimum of two stages.

3.Specific kW ratings are available within the ranges shown. Refer to selection program.

4.Heaters above 480v must utilize one time secondary limits only.

8

ENVIRO-TEC

Page 8
Image 8
Enviro 170S5FG manual Mql Electric Heat