Horizontal Vent Kit

50-1235

Please read and understand these instructions before installing. Failure to follow these

instructions carefully could cause property damage or personal injury.

For use with Haven & Retreat Direct Vent fireplaces.

KIT COMPONENTS:

Quantity

Description

Quantity

Description

 

 

 

 

1

Horizontal direct vent termination cap

4

Wire spacers

 

 

 

 

1

Flue collar adapter

1

4 oz tube Mill-Pac Sealant

 

 

 

 

1

Wall thimble

1

4 oz tube RTV silicone

 

 

 

 

 

1

5’

(190 cm) length of Ø4” (10 cm) double walled flex pipe

12

9/16” tech screws

1

5’

(190 cm) length of Ø6⅝” (10 cm) double walled flex pipe

8

1½” wood screws

 

 

 

 

 

Please ensure that all components are supplied with this kit. If components are missing or have been damaged, contact your dealer, distributor, or courier company. Do not attempt the installation if components are missing or damaged.

INSTALLATION INSTRUCTIONS:

10"

(254mm)

1. Plan your installation and clearances to combustibles. Decide on a location

 

for the unit that will meet any or all local code requirements. Refer to the

10"

sections in your owner’s manual on where to locate your stove.

(254mm)

2. Set the appliance in the desired location. Determine if any wall studs,

 

electrical wiring, or plumbing pipes are in the way of the venting system

 

as it passes through the exterior wall. The fireplace location should be

 

adjusted if obstructions are found in the wall.

 

 

3. Project a line from the center point of the flue

 

 

 

 

outlet upward and outward to the desired flue

 

 

outlet location on the exterior wall. Using this

 

 

center point, scribe a 10” (25.4 cm) hole or

 

 

square on the wall. Cut the hole out on both

 

 

Figure 1

 

the interior and exterior wall surfaces.

 

4. Frame the hole as shown in Figure 1.

 

 

5. Trim the Wall Thimble to match the wall thickness as necessary. Install the wall

 

thimble and secure it to the inner wall frame using four (4) 1½” wood screws.

Wire

6. Apply a bead of Mill-Pac Black sealant to the new Ø4” (10 cm) by 5” (12.5 cm)

spacers

provided flue collar adaptor. Press the flue collar into the flue outlet of the

 

 

fireplace so that the Mill-Pac seals the flue collar to the flue outlet.

 

7. Stretch both the Ø4” (10 cm) flex vent and the Ø6⅝” (16.25 cm) flex intake

 

liner to the length needed to ensure the flex can be easily connected to the vent

 

terminal.

 

 

8. Slide the Ø6⅝” (16.25 cm) flex intake liner over the flex vent. Install four (4)

 

wire spacers around the flex pipe. Ensure the wire spacers are positioned at

 

either end of the pipes, and at each end of any elbows in the liners (refer to

 

Figure 2 and 3).

 

 

 

 

Figure 2

Page 1
Image 1
Enviro installation instructions Horizontal Vent Kit 50-1235, KIT Components, Quantity Description