12. ROUTINE MAINTENANCE
Periodically check to ensure that the
Periodically check the pilot and burner flames (See Fig.11)
CLEANING OF GLASS
Do not clean glass when hot
It will be necessary to clean the ceramic glass periodically. During a cold start up condensation will sometimes form on the glass, this is a normal condition with all gas fireplaces and stoves. However, sometimes this condensation can allow dust and lint to cling to the glass surface. Also, sometimes initial paint curing of the appliance can leave behind a slight film on the glass. This is a temporary problem. It is therefore recommended that the glass be cleaned initially after about the first two weeks of use.
After that, depending upon the amount of use, cleaning should be required no more than two or three times per season.
To clean the door, use a mild glass cleaner and a soft cloth. Abrasive cleaners will damage the glass surface.
OPENING THE GLASS DOOR
Turn unit off and wait until the appliance has cooled down.
1.Open the right hand hinged side flap which will expose a door fastener. Using a 1/2" wrench, loosen the fastener.
2.Due to the shape of the bay window door. You must also open the left hand side flap before attempting to open the door.
3.Ensure the door is properly fastened after cleaning before attempting to
TO REPLACE DOOR AND GLASS ASSEMBLY
The glass in this appliance is an integral part of the door assembly. If the glass is damaged or broken a
15
replacement door assembly including glass must be fitted.
To Replace
•open door fully
•Lift door vertically so that hinge pins lift out of hinge receivers.
•Return assembly to dealer.
The Door and glass assembly must be replaced as a complete unit by your ENVIROGAS Dealer. No
substitute materials are allowed.
FOR CLEANING THE INSIDE OF THE FIREBOX
Remove the log carefully from the firebox. Gently remove the embers and place on a piece of paper towel.
Vacuum the firebox thoroughly. Carefully clean off any dust on the logs and remove any lint from the main burners and pilot burner.
After carefully replacing the log and embers in their correct positions, and the door has been resealed,
CLEARANCES MUST BE SUFFICIENT TO ALLOW ACCESS FOR MAINTENANCE AND SERVICE
LUBRICATING THE BLOWER
Every 6 months the blower should be lubricated if installed
1.Turn the unit off and remove the log set.
2.Remove the burner tray assembly by removing the screw on either side of the tray, between the front and rear burners. Lift tray out.
3.Remove the 8 screws that hold the blower mounting plate to the back firewall.
4.Carefully pull the blower assembly into the firebox, exposing the blower lubricating holes ( located on the top of the motor housing on either side of the label). Add 2 drops of SAE 20 oil.
5.If removal of the blower is necessary, disconnect the blower leads from the harness. Remove the blower.
6.To