Operating Instructions

OPERATING YOUR PELLET STOVE:

PRE-BURN INSTRUCTIONS: The burn pot liner holes must be clear and the liner installed correctly against the ignitor tube for proper operation. Check the hopper for enough pellets to start the unit.

DO NOT OPERATE THE UNIT WITH THE DOOR OR ASH PAN OPEN.

MANUAL MODE:

To START: Press the ON / OFF button. The stove will turn on. The system light will flash. The Auger Light will flash with each pulse of the auger (the Auger Feed Rate is pre-programmed during start-up). The Heat Level Indicator will show the Heat Level that the stove will run at after start-up.

If this is the first time the unit has been started or the unit has run out of fuel, the auger will need to be primed. Press the Manual Auger Feed button until fuel starts to drop into the Burn Pot Liner (see

“OPERATING INSTRUCTIONS - CONTROL BOARD FUNCTIONS”).

To OPERATE: When a fire has been established, the System Light will turn solid (after approximately 10

-15 minutes) and the Auger Light will continue to flash to the corresponding Heat Level setting. The Heat Level button can now be pressed at this time to change the desired Heat Level Output setting.

The convection blower (room air blower) will turn on. The speed of this blower is controlled by the setting of the heat level output indicator.

When operating on LOW HEAT LEVEL, the feed rate can be adjusted, using the auger trim, for different quality fuels. These settings can be used if the fire keeps going out on low (for poor quality fuel) or if the

low setting is too hot for the room (see “OPERATING INSTRUCTIONS - CONTROL BOARD FUNCTIONS”).

THERMOSTAT / SWITCH MODE:

INITIAL START-UP: See above

OPERATION - HI / LOW mode: When the thermostat contacts are closed the stove settings are adjustable as per Manual Mode (see above). When the thermostat contacts open, the circuit board will take control of the settings. The stove will drop down to a low burn until the thermostat contacts close again. This low burn setting can be adjusted for different fuel qualities (see “OPERATING INSTRUCTIONS

-CONTROL BOARD FUNCTIONS”). The stove will come back to the previous HEAT LEVEL setting when the thermostat contacts close again.

OPERATION – ON / OFF mode: When the thermostat contacts close, the unit will light automatically. Once up to temperature, the stove operates the same as in manual mode (see above). When the thermostat contacts open, the unit automatically begins its shutdown routine. The stove will re-light when the thermostat contacts close again.

TURNING YOUR PELLET STOVE OFF:

MANUAL and HI / LOW mode: To turn the unit OFF, simply press the ON / OFF button. This will stop the feed of pellets. The blowers will continue to operate and cool the stove down. When cool enough, the stove will turn off.

ON / OFF mode: To turn the unit OFF, turn the thermostat down or off.

DO NOT unplug unit while Combustion fan is operating.

This may lead to smoke escaping from the stove.

9

Page 9
Image 9
Enviro 50-1266, C-11112 owner manual Thermostat / Switch Mode, Initial START-UP See above

C-11112, 50-1266 specifications

Enviro 50-1266, also known by its designation C-11112, is a cutting-edge product that stands out in the realm of environmentally friendly solutions. It is designed with a focus on sustainability while delivering high performance in various applications. One of its main features is its biodegradable composition, which significantly reduces environmental impact compared to traditional products. This aspect appeals to both consumers and businesses looking to adopt greener practices.

The product is formulated using advanced technologies that enhance its effectiveness. One of these technologies involves the incorporation of bio-based materials that exhibit exceptional durability and resistance to degradation. This ensures that the product maintains its integrity over time, even in challenging environments, while still being safe for the ecosystem.

Furthermore, Enviro 50-1266 features a unique formulation that allows for versatile usage across different sectors, from agriculture to industrial applications. Whether used as a cleaner, lubricant, or in manufacturing processes, its performance remains consistent and reliable. Additionally, the product is designed to be user-friendly, facilitating easy application without the need for specialized equipment or extensive training.

Another noteworthy characteristic of Enviro 50-1266 is its non-toxic nature, making it suitable for use around children and pets. This feature broadens its appeal, particularly among environmentally conscious consumers and organizations. The product not only meets but often exceeds regulatory standards for safety and environmental compliance, further establishing its credibility in the market.

In terms of customer support, the manufacturers provide comprehensive resources, including detailed guidelines for optimal use and applications. They also offer responsive customer service to address any inquiries or concerns, which enhances the overall user experience.

In summary, Enviro 50-1266, C-11112, is a versatile, sustainable solution that excels in various applications while prioritizing environmental responsibility. Its biodegradable composition, advanced manufacturing technologies, and user-friendly characteristics make it a notable choice for those seeking effective and eco-friendly alternatives. With a commitment to safety and compliance, this product not only meets modern demands but also contributes positively to the preservation of our planet.