Enviro C-11275 owner manual Initial Installation, Qualified Installers Only

Models: C-11275

1 42
Download 42 pages 32.42 Kb
Page 14
Image 14
Initial Installation

Initial Installation

QUALIFIED INSTALLERS ONLY

INTRODUCTION:

This section of the owner’s manual is for the use of qualified technicians only. Fireplace placement, hearths, facing, mantels, and venting terminations will be covered, as well as the gas and electric systems. There are several installation safety guidelines that must be adhered to. Please carefully read the safety precautions at the front of this manual.

Warning: Clearances must be sufficient to allow access for maintenance and service.

PLACEMENT AND FRAMING:

Table 2. Framing Dimensions.

 

 

 

���

 

 

 

 

 

�����

 

 

 

 

 

������

 

 

 

 

 

 

 

 

 

 

 

 

��

 

 

 

 

 

���

 

 

 

 

 

 

 

 

 

 

�������

 

��

 

 

��

 

 

�� ���

 

�������

 

 

 

��

 

 

����

������

 

 

�������

 

 

 

 

 

 

�������

 

 

 

 

 

 

 

 

Figure 15. Dimensions for Framing the Firebox.

Firebox Framing

Depth

131⁄4”

33.7 cm

Width

361⁄4”

92.1 cm

Height

377⁄8”

96.2 cm

 

 

 

Gas/Electrical Inlet:

 

 

 

 

Distance back

55⁄8”

14.3 cm

 

 

 

Distance up

35⁄8”

9.3 cm

 

 

 

The location for the fireplace can be along a wall, raised or at floor level, or in a corner. There are specific framing measurements for each situation. The basic opening should have the dimensions shown in Figure 15.

The fireplace must have a strong and level surface to be placed on. The surface should be made of wood or a non-combustible material, not carpet.

The framing boards may touch the top and back standoffs, but no insulating material can be placed between the frame and the standoffs.

The gas line, 3⁄8 inch NPT, should be brought to the right side of the fireplace. If this set up is inconvenient, the electrical wire and the gas line configuration can be reversed.

The location should be chosen so the fireplace will be at least 36 inches (91.4 cm) from drapes, doors and other combustibles. The framed opening should also be a minimum of 1 inches (2.5 cm) from the nearest perpendicular wall (sidewall to the edge of the opening).

The DV36 is designed so it can be installed at floor level without a required hearth.

14

Page 14
Image 14
Enviro C-11275 owner manual Initial Installation, Qualified Installers Only