Codes And Approvals

DIRECT VENT: This type is identified by the suffix DV. This appliance draws all of its air for combustion from outside the dwelling, through a specially designed vent pipe system.

This appliance has been tested and approved for installations from 0 feet to 4500 feet (1372 m) above sea level.

BV: This Vented appliance draws all of its combustion air from the dwelling and must be vented using listed B or L vent. May also be vented through a conventional chimney using a chimney liner kit.

This appliance has been tested and approved for installations from 0 feet to 2000 (610 m) above sea level.

In the USA: The appliance may be installed at higher altitudes. Please refer to your American Gas Association guidelines which state: the sea level rated input of Gas Designed Appliances installed at elevations above 2000 (610 m) feet is to be reduced 4% for each 1000 feet (305 m) above sea level. Refer also to local authorities or codes which have jurisdiction in your area regarding the de-rate guidelines.

In Canada: When the appliance is installed at elevations above 4500 feet (1372 m), the certified high altitude rating shall be reduced at the rate of 4% for each additional 1000 feet (305 m).

This appliance has been tested by INTERTEK (Warnock Hersey) and found to comply with the established VENTED GAS FIREPLACE HEATER standards in CANADA and the USA as follows:

VENTED GAS FIREPLACE HEATER (FOCUS BV/DV; NG/LPG)

TESTED TO: ANSI Z21.88a-2003/CSA 2.33a-2003 VENTED GAS FIREPLACE HEATERS

CAN/CGA 2.17-M91 GAS FIRED APPLIANCES FOR HIGH ALTITUDES

CSA P.4.1-02 TESTING METHOD FOR MEASURING ANNUAL FIREPLACE EFFICIENCY

This ENVIRO FOCUS Fireplace:

Has been certified for use with either natural or propane gases. (See rating label.)

Is not for use with solid fuels.

Is approved for bedroom or bed sitting room. (IN CANADA: must be installed with a listed wall thermostat. IN USA: see current ANSI Z223.1 for installation instructions.)

• Must be installed in accordance with local codes. If none exist, use current installation code CAN/CGA B149 in Canada or ANSI Z223.1/NFPA 54 in the USA.

• Must be properly connected to an approved venting system and not connected to a chimney flue serving a separate solid-fuel burning appliance.

Is not approved for closet or recessed installations.

Must have inner flat unit glass installed before bay window can be installed.

IMPORTANT NOTICE (Regarding first fire up): When the unit is turned on for the first time, it should be turned onto high without the fan on for the first 4 hours. This will cure the paint, logs, gasket material and other products used in the manufacturing process. It is advisable to open a window or door, as the unit will start to smoke and can irritate some people. After the unit has gone through the first burn turn the unit off including the pilot, let the unit get cold then remove the glass door and clean it with a good gas fireplace glass cleaner, available at your local ENVIRO dealer.

4

Page 4
Image 4
Enviro C-11288 owner manual Codes And Approvals, This Enviro Focus Fireplace

C-11288 specifications

Enviro C-11288 is an innovative product that has garnered attention in the environmental technology sector. Primarily designed for sustainability initiatives, this advanced solution integrates a range of features and technologies that address the pressing concerns of waste management and resource conservation.

One of the standout features of Enviro C-11288 is its efficient waste processing capability. Utilizing state-of-the-art waste conversion technologies, it can transform organic and inorganic materials into reusable resources, effectively minimizing landfill use. The incorporation of advanced sorting algorithms ensures that the separation of recyclable materials is efficient and precise, enhancing the overall recycling process.

In addition to waste processing, the Enviro C-11288 is equipped with energy recovery systems. These systems capture and convert waste heat generated during processing into usable energy. This not only energy-optimizes the operation but also contributes to a lower carbon footprint, making it an environmentally friendly solution.

Another significant characteristic of the Enviro C-11288 is its scalability. Whether in a small community or a large industrial setup, the unit can be adapted to meet varying demands. This flexibility is further enhanced by modular design features, allowing users to expand or contract the system as needed without significant interruptions to their operations.

The technology behind Enviro C-11288 is also notable. Real-time monitoring and analytics capabilities enable users to track efficiency metrics, waste reduction rates, and energy consumption. This data-driven approach empowers organizations to make informed decisions about resource management and further improvements.

Durability and low maintenance are additional advantages provided by Enviro C-11288. Constructed with high-quality materials, the system is designed for longevity and can withstand harsh operational conditions. Low maintenance requirements translate into cost savings over time, further appealing to organizations with budget constraints.

Overall, Enviro C-11288 represents a significant advancement in environmental technology solutions. Its combination of waste management efficiency, energy recovery, scalability, real-time monitoring, and durable design positions it as a vital tool for organizations striving to implement sustainable practices while optimizing resource use. As industries continue to emphasize sustainability, the Enviro C-11288 offers a comprehensive solution that aligns with this critical goal.