Maintenance and Service

Periodically check to ensure that your direct vent system is clean.

Periodically check the pilot and burner. Check to see that all the burner ports are clean and clear. Check the pilot head for blockage. Check to ensure the pilot flame is blue with no or very small yellow tips.

OPENING THE DOOR:

Turn unit off and wait until the appliance has cooled down.

1.Open the right hand hinged side flap, which will expose a door fastener. Using a 1⁄2” wrench, loosen the fastener.

2.Due to the shape of the bay window door. You must also open the left-hand side flap before attempting to open the door.

3.If the door must be removed open the door and lift the door pins out of the hinges (see figure 6).

4.Ensure the door is properly fastened after cleaning before attempting to re-light the appliance.

CLEANING THE GLASS:

���� ��

��� ������ �����

Figure 6: Removing the Door.

Allow the glass to cool before cleaning. It will be necessary to clean the ceramic glass periodically. During a cold start up, condensation will sometimes form on the glass. This is a normal condition with all gas fireplaces and stoves. However, this condensation can allow dust and lint to cling to the glass surface. Initial paint curing of the appliance can leave behind a slight film on the glass. This is a temporary problem. It is therefore recommended that the glass be cleaned initially after about the first four hour of use. Depending upon the amount of use, cleaning should be required no more than two or three times per season. To clean the door, use a mild glass cleaner and a soft cloth or a glass cleaner available from your Enviro dealer. Abrasive cleaners will damage the glass.

TO REPLACE DOOR:

The glass in this appliance is an integral part of the door assembly. If the glass is damaged or broken a replacement inner door with glass assembly must be purchased.

The glass in this appliance is ceramic. If the glass is damaged or broken a factory door with glass replacement must be used.

Remove the door with glass, a new door assembly must be purchased from an ENVIRO dealer (part #: EG28-103). Do not use a substitute materials; it will void the warranty.

CLEANING THE INSIDE OF THE FIREBOX:

1.Turn off the unit and allow it to cool down completely.

2.Remove the logs carefully from the firebox. Gently remove the embers and place on a piece of paper towel, until ready to replace.

3.Vacuum the bottom of the firebox thoroughly. Carefully clean off any dust on the logs and remove any lint from the main burner and pilot burner.

4.After carefully replacing the log and embers in their correct positions (see SECONDARY INSTALLATION - INSTALLATION OF LOG SET AND EMBERS), and the door has been resealed, re-light the pilot, following the instructions on the lighting label attached to the unit.

8

Page 8
Image 8
Enviro EG28 DV, EG28-120 owner manual Maintenance and Service, Removing the Door

EG28-120, EG28 DV specifications

The Enviro EG28 DV and EG28-120 are cutting-edge devices designed for enhancing environmental monitoring and improving overall efficiency in various applications. These units are part of Enviro's commitment to sustainable innovation, catering to industries such as agriculture, industrial processes, and smart cities.

One of the standout features of the Enviro EG28 DV is its advanced sensor technology. This device is equipped with high-precision sensors that can measure a range of environmental parameters, including air quality, temperature, humidity, and even soil metrics. The ability to gather diverse data points in real-time allows users to make informed decisions, ultimately leading to better resource management and environmental conservation.

The EG28-120 variant takes this a step further with its enhanced connectivity options. It supports various communication protocols, including Wi-Fi, Bluetooth, and cellular networks, ensuring seamless integration into existing systems. This connectivity not only facilitates remote monitoring but also enables data sharing across different platforms, making it easier for stakeholders to access crucial information and collaborate effectively.

Both models boast user-friendly interfaces, complete with intuitive dashboards that simplify data visualization. Users can easily track readings, analyze trends, and generate reports, which is essential for regulatory compliance and performance assessment. The devices are also complemented by mobile applications, allowing for on-the-go monitoring and alerts, thus promoting proactive management of environmental factors.

Durability is another critical aspect of the Enviro EG28 DV and EG28-120. Designed to withstand challenging conditions, these devices feature rugged exteriors and are resistant to dust and water, ensuring reliable performance in various environments. Their low power consumption is an added advantage, making them suitable for long-term deployment without frequent maintenance.

In summary, the Enviro EG28 DV and EG28-120 stand out for their advanced sensor capabilities, versatile connectivity, user-friendly design, and robust durability. These features make them invaluable tools for monitoring environmental conditions, supporting industries in their quest for sustainable practices and efficient resource management. With their innovative technologies, these devices are poised to play a significant role in shaping the future of environmental stewardship.