Initial Installation

GAS LINE CONNECTION AND TESTING:

WARNING: Only persons licensed to work with gas piping may make the necessary gas connections to this appliance.

GAS LINE CONNECTION

This stove is equipped with a certified flexible pipe located on the right side of the unit terminating in a 3⁄8” male NPT fitting. Consult your local authorities codes or the CAN/CGA B 149 (1 or 2) installation code in Canada, or in the USA gas installations follow either local codes or the current edition of the National Fuel Gas Code ANSI Z223.1.

The efficiency rating of this appliance is a product thermal efficiency rating determined under continuous operating conditions and was determined independently of any installed system.

The appliance and its shutoff valves must be disconnected from the gas supply piping system during any pressure testing where the pressure exceeds 1⁄2 PSIG (3.45 KPa) or damage will occur to the valve.

The appliance must be isolated from the gas supply piping system by closing its individual manual shutoff valve during any pressure testing of the gas supply piping system at test pressures equal to or less than 1⁄2 psig (3.45 KPa).

Always check for gas leaks with a soap and water solution after completing the required pressure test.

TO TEST VALVE PRESSURES

 

 

��������

 

�����

 

 

 

�������� ���

 

 

�������� ���

 

 

 

 

 

TP TH

 

OUT

IN

 

 

 

 

 

TP

H

O

 

 

I

L

OF

 

 

 

 

 

 

 

F

 

 

 

 

P

TH

 

 

I

 

 

L

 

 

T

O

 

 

 

 

 

 

NO

 

T

P

 

 

 

I

 

 

 

OL

 

 

 

 

����� ����������

������

 

��� �������

�����

����

 

����

Figure 39: Fully Labeled Gas Valve.

The pressure taps are located on the left side of the valve

Turn set screw 1 turn counter clockwise to loosen,

Place 5/16” (8 mm) I.D. hose over pressure tap system.

Check pressures using a manometer.

When finished, release pressure, remove hose & tighten set screw.

Table 8: Pressure and BTU Information.

 

Natural Gas

Propane

 

 

 

Main Orifice

#43 DMS

#53 DMS

 

 

 

Manifold Pressure

3.8” W.C. (0.95 KPa)

11.0” W.C. (2.74 KPa)

 

 

 

Min. Manifold Pressure

1.1” W.C. (0.27 KPa)

2.7” W.C. (0.67 KPa)

 

 

 

Max Supply Pressure

7.0” W.C. (1.74 KPa)

12.0” W.C. (2.98 KPa)

 

 

 

Min. Supply Pressure

5.0” W.C. (1.25 KPa)

11.5” W.C. (2.86 KPa)

 

 

 

Max BTU/hr Input

26,500 BTU/hr (7.87 KW)

26,500 BTU/hr (7.87 KW)

Min. BTU/hr Input

13,500 BTU/hr (3.9 KW)

13,500 BTU/hr (3.9 KW)

NEVER USE AN OPEN FLAME FOR LEAK TESTING.

28

Page 28
Image 28
Enviro EG28 DV Natural Gas Propane Main Orifice, Min. Manifold Pressure, Max Supply Pressure, Min. Supply Pressure

EG28-120, EG28 DV specifications

The Enviro EG28 DV and EG28-120 are cutting-edge devices designed for enhancing environmental monitoring and improving overall efficiency in various applications. These units are part of Enviro's commitment to sustainable innovation, catering to industries such as agriculture, industrial processes, and smart cities.

One of the standout features of the Enviro EG28 DV is its advanced sensor technology. This device is equipped with high-precision sensors that can measure a range of environmental parameters, including air quality, temperature, humidity, and even soil metrics. The ability to gather diverse data points in real-time allows users to make informed decisions, ultimately leading to better resource management and environmental conservation.

The EG28-120 variant takes this a step further with its enhanced connectivity options. It supports various communication protocols, including Wi-Fi, Bluetooth, and cellular networks, ensuring seamless integration into existing systems. This connectivity not only facilitates remote monitoring but also enables data sharing across different platforms, making it easier for stakeholders to access crucial information and collaborate effectively.

Both models boast user-friendly interfaces, complete with intuitive dashboards that simplify data visualization. Users can easily track readings, analyze trends, and generate reports, which is essential for regulatory compliance and performance assessment. The devices are also complemented by mobile applications, allowing for on-the-go monitoring and alerts, thus promoting proactive management of environmental factors.

Durability is another critical aspect of the Enviro EG28 DV and EG28-120. Designed to withstand challenging conditions, these devices feature rugged exteriors and are resistant to dust and water, ensuring reliable performance in various environments. Their low power consumption is an added advantage, making them suitable for long-term deployment without frequent maintenance.

In summary, the Enviro EG28 DV and EG28-120 stand out for their advanced sensor capabilities, versatile connectivity, user-friendly design, and robust durability. These features make them invaluable tools for monitoring environmental conditions, supporting industries in their quest for sustainable practices and efficient resource management. With their innovative technologies, these devices are poised to play a significant role in shaping the future of environmental stewardship.