ELECTRICAL

The ENVIROGAS EG 40.FS.BV. will operate with no external power supply. These models have a Milli volt gas control which uses the pilot flame to generate enough electricity to operate the main burner.

The appliance when installed, must be electrically connected and grounded in accordance with local codes or in the absence of local codes, with the current CSA C22.1 CANADIAN ELECTRICAL CODE. Part 1, SAFETY STANDARDS FOR ELECTRICAL INSTALLATIONS, or THE NATIONAL ELECTRICAL CODE ANSI / NFPA 70 in the USA.

NOTE:

Operation of the fan increases the efficiency and the heat output of the appliance.

The thermostat connects to the two purple wires in the harness

Control panel light uses a 7w Max. bulb

CAUTION

Label all wires

prior to

disconnection when servicing controls. Wiring errors can cause improper and dangerous operation. Verify proper operation after servicing.

WARNING: ELECTRICAL GROUNDING INSTRUCTIONS. This appliance is equipped with a three-prong (grounding) plug for your protection against shock hazard and should be plugged into a properly grounded three-prong receptacle.

DO NOT cut or remove the grounding prong from the plug.

INSTALLING REMOTE THERMOSTAT OR WALL SWITCH

RECOMMENDED WIRE SIZE for thermostat installation: 18 gauge, 2 wire solid core, Low Voltage wire. (Bell wire)

1.Install the 18 Gauge wire supplied to the two terminals on the thermostat or remote wall switch.

2.Connect the other end of the wire to the gas valve using the two outside terminals on the front of the gas valve. Use the terminals marked (TP/TH and TH).

RECOMMENDED MAXIMUM LEAD LENGTH (TWO WIRE)

WHEN USING WALL THERMOSTAT

WIRE SIZE

MAXIMUM LENGTH

14 GAUGE

100 FEET

16 GAUGE

64 FEET

18 GAUGE

40 FEET

20 GAUGE

18 FEET